Application Catalog



Operating time analysis
116 - Operating Time Analysis of an Injector by Evaluating the Reduction in Eddy Currents 116 - Operating Time Analysis of an Injector by Evaluating the Reduction in Eddy Currents
Module:TR 2011-07-12
A solenoid type injector used in engines opens a valve and injects fuel by moving a plunger with magnetic force created by an electromagnet.The response for the applied voltage is evaluated to improve the fuel consumption by maintaining the flow of fuel dispersed by an injector into an engine.Evaluating ways to reduce the eddy currents to improve the response characteristics of an injector is advantageous because the eddy currents produced by the currents slow the response of the injector.
This example presents the use of a magnetic field analysis to obtain the response characteristics of a solenoid type injector by evaluating ways to reduce the amount of eddy currents.
109 - Operating Time Analysis of an Electromagnetic Relay Accounting for Eddy Currents 109 - Operating Time Analysis of an Electromagnetic Relay Accounting for Eddy Currents
Module:TR 2011-01-17
Electromagnetic relays are devices that connect and disconnect contact points physically using an electromagnet.The magnetic attraction that activates the relay is generated by the magnetomotive force, which is expressed by the product of coil turns and current.The operating time can be calculated from the magnetic attraction at the moveable core using an equation of motion.This example presents the use of a magnetic field analysis to evaluate the operating time of an electromagnetic relay driven by direct current accounting for the eddy currents.
66 - Operating Time Analysis of an Injector 66 - Operating Time Analysis of an Injector
Module:DP 2011-07-12
Solenoid injectors used for engines are mechanisms that spray fuel through the valve which opens when the plunger is moved by magnetic force from an electromagnet. Injectors in engines need to respond quickly to applied voltage to improve fuel consumption by maintaining the fuel flow. In solenoid injectors, one factor causing the response delay is eddy currents produced by the current flow. This note presents the use of magnetic field analysis to obtain the response characteristics of a solenoid injector.
36 - Operating Time Analysis of an Electromagnetic Relay 36 - Operating Time Analysis of an Electromagnetic Relay
Module:TR 2011-02-28
Electromagnetic relays are devices that connect and disconnect contact points physically using an electromagnets.?The magnetic attraction that activates the relay is generated by the magnetomotive force, which is expressed by the product of coil turns and the current. The operating time can be calculated from the magnetic attraction using an equation of motion. This note presents the use of a magnetic field analysis to evaluate the operating time of a DC relay.






Contact US