  1. [RTML-046] ALTERNATOR_01

    Features and principal useGeometry display on JMAG-DesignerTypeModelALTERNATOR_01Model nameALTERNATORDirect current voltage (Field)DC200(V)Number of Poles12Number of Slots36Number of Phases3RotorWFStator (Outside Diameter)140(mm)Stator (Inside Diame…

    6 Mar 2018

  2. [RTML-045] LSM_01

    Features and principal useGeometry display on JMAG-DesignerTypeModelLSM_01Model nameLSMMax. Power2(kW)Direct current voltageDC400(V)Number of Poles4Number of Slots24Number of Phases3MoverSPMMover (Length)200(mm)Mover (Width)100(mm)StatorDistributed …

    6 Mar 2018

  3. [RTML-044] SRM_01

    Features and principal useGeometry display on JMAG-DesignerTypeModelWFSM_01Model nameWFSMMax. Power2(kW)Voltage/Current (armature)DC200(V)/20(A)Voltage/Current (field)DC100(V)/10(A)Number of Poles8Number of Slots48Number of Phases3RotorWFStator (Out…

    6 Mar 2018

  4. [RTML-043] SRM_01

    Features and principal useGeometry display on JMAG-DesignerTypeModelSRM_01Model nameSRMMax. Power0.5(kW)Voltage/CurrentDC150(V)Number of Poles4Number of Slots6Number of Phases3RotorRMStator (Outside Diameter)160(mm)Stator (Inside Diameter)90.6(mm)St…

    6 Mar 2018

  5. [RTML-042] SynRM_01

    Features and principal useGeometry display on JMAG-DesignerCircuit Diagram (Left: Whole Circuit, Right: Star Connection)TypeModelSynRM_01Model nameSynRMMax. Power0.01(kW)Voltage/CurrentDC288(V)/5(A)Number of Poles4Number of Slots24Number of Phases3R…

    6 Mar 2018

  6. [RTML-041] PMSTEP_01

    Features and principal useGeometry display on JMAG-DesignerTypeModelPMSTEP_01Model namePMSTEPVoltage/CurrentDC24(V)Number of Poles24RotorPMNumber of phase2Number of Turns270Step angle7.5(deg)Stator (Outside Diameter)60.0(mm)Stator (Inside Diameter)2…

    6 Mar 2018

  7. PMSM/SPM Constant rating 1(kW) No#040

    Features and principal useSquare, Power source for compact air conditioner compressors etc.Geometry display on JMAG-ExpressCircuit DiagramTypeModel1k_S_D_S_6PModel namePMSMMax. Power1(kW)Voltage/CurrentDC100(V)/10(A)Number of Poles4Number of Slots24…

    6 Mar 2018

  8. [RTML-039] SOLENOID_01

    Features and principal useGeometry display on JMAG-DesignerTypeModelSOLENOID_01Stroke length3.5(mm)Dimension of a movable coreDiameter 11.0(mm)Height 15.0(mm)Mass of a movable core0.01(kg)Dimension of a stator coreInner diameter 5.0(mm)Outer diamete…

    6 Mar 2018

  9. [RTML-038] IM Constant rating 10(kW)

    Features and principal useHighly efficient, Square, Power source for middle-size equipmentGeometry display on JMAG-ExpressResult display on JMAG-RT Viewer Type3TypeModel10k_S_D_IMModel nameIMMax. Power10(kW)Voltage/CurrentDC500(V)/250(A)Number of Po…

    6 Mar 2018

  10. [RTML-037] IM Constant rating 1(kW)

    Features and principal useSquare, Power source for compact air conditioner compressors etc.Geometry display on JMAG-ExpressResult display on JMAG-RT Viewer Type3TypeModel1k_S_D_IMModel nameIMMax. Power1(kW)Voltage/CurrentDC100(V)/5(A)Number of Poles…

    6 Mar 2018

  11. [RTML-036] PMSM/SPM Constant rating 100(kW)

    Features and principal useSlim type, Power source for large-size equipmentGeometry display on JMAG-ExpressResult display on JMAG-RT Viewer Type3TypeModel100k_D_C_SModel namePMSMMax. Power100(kW)Voltage/CurrentDC500(V)/400(A)Number of Poles12Number o…

    6 Mar 2018

  12. [RTML-035] PMSM/IPM Constant rating 100(kW)

    Features and principal useSlim type, Power source for large-size equipmentGeometry display on JMAG-ExpressResult display on JMAG-RT Viewer Type3TypeModel100k_D_C_I-Model namePMSMMax. Power100(kW)Voltage/CurrentDC500(V)/400(A)Number of Poles12Number …

    6 Mar 2018

  13. [RTML-034] PMSM/IPM Constant rating 100(kW)

    Features and principal useHighly efficient, Slim type, Power source for large-size equipmentGeometry display on JMAG-ExpressResult display on JMAG-RT Viewer Type3TypeModel100k_D_C_IVModel namePMSMMax. Power100(kW)Voltage/CurrentDC500(V)/200(A)Number…

    6 Mar 2018

  14. [RTML-033] PMSM/SPM Constant rating 100(kW)

    Features and principal useSlim type, Power source for large-size equipmentGeometry display on JMAG-ExpressResult display on JMAG-RT Viewer Type3TypeModel100k_D_D_SModel namePMSMMax. Power100(kW)Voltage/CurrentDC500(V)/400(A)Number of Poles12Number o…

    6 Mar 2018

  15. [RTML-032] PMSM/IPM Constant rating 100(kW)

    Features and principal useSlim type, Power source for large-size equipmentGeometry display on JMAG-ExpressResult display on JMAG-RT Viewer Type3TypeModel100k_D_D_I-Model namePMSMMax. Power100(kW)Voltage/CurrentDC500(V)/400(A)Number of Poles12Number …

    6 Mar 2018

  16. [RTML-031] PMSM/IPM Constant rating 100(kW)

    Features and principal useSlim type, Power source for large-size equipmentGeometry display on JMAG-ExpressResult display on JMAG-RT Viewer Type3TypeModel100k_D_D_IVModel namePMSMMax. Power100(kW)Voltage/CurrentDC500(V)/400(A)Number of Poles12Number …