[RTML-014] PMSM/IPM Constant rating 10(kW)

Sign in to download the data

RTT file Simulink sample Circuit

Features and principal use

Highly efficient, Square, Power source for middle-size equipment

Geometry display on JMAG-Express

Geometry display on JMAG-Express

Result display on JMAG-RT Viewer Type3

Result display on JMAG-RT Viewer Type3

Type

Model 10k_S_D_I-
Model name PMSM
Max. Power 10(kW)
Voltage/Current DC240(V)/60(A)
Number of Poles 6
Number of Slots 18
Number of Phases 3
Rotor IPM
Stator (Outside Diameter) 115(mm)
Stator (Inside Diameter) 59(mm)
Stator Distributed winding
Number of Turns 12
Height 120(mm)
Magnet Neodymium sintered
Inertia Moment 8.85e-4(kg路m^2)
Mass 9.92(kg)
Max. Current 84.8(Apeak)

Calculation results of JMAG-Designer

Average torque(N路m) 23(N路m)
Ld 0.69(mH)
Lq 1.31(mH)
Inductance 0.73(mH)
Torque constant 0.269(N路m/A)

Calculation condition of efficiency map using JMAG-RT Viewer
Motor Control

Max.Speed 8000(r/min)
Control Type Max. Power

Inverter

Max.Voltage 240(V)
Max.Current 84.8(Apeak)
Efficiency Operating range
not less than 90% 91.2(%)
not less than 80% 95.7(%)
not less than 70% 97.1(%)
not less than 60% 97.8(%)
not less than 50% 98.2(%)

* Iron Loss is accounted.