[RTML-025] PMSM/IPM Constant rating 100(kW)

Sign in to download the data

RTT file Simulink sample Circuit

Features and principal use

Square, Power source for large-size equipment

Geometry display on JMAG-Express

Geometry display on JMAG-Express

Result display on JMAG-RT Viewer Type3

Result display on JMAG-RT Viewer Type3

Type

Model 100k_S_D_IV
Model name PMSM
Max. Power 100(kW)
Voltage/Current DC500(V)/400(A)
Number of Poles 8
Number of Slots 48
Number of Phases 3
Rotor IPM
Stator (Outside Diameter) 250(mm)
Stator (Inside Diameter) 143(mm)
Stator Distributed winding
Number of Turns 2
Height 259(mm)
Magnet Neodymium sintered
Inertia Moment 7.24e-2(kg路m^2)
Mass 99.76(kg)
Max. Current 283(Apeak)

Calculation results of JMAG-Designer

Average torque(N路m) 178(N路m)
Ld 0.26(mH)
Lq 0.56(mH)
Inductance 0.26(mH)
Torque constant 0.629(N路m/A)

Calculation condition of efficiency map using JMAG-RT Viewer
Motor Control

Max.Speed 9000(r/min)
Control Type Max. Power

Inverter

Max.Voltage 500(V)
Max.Current 283(Apeak)
Efficiency Operating range
not less than 90% 85.8(%)
not less than 80% 93.4(%)
not less than 70% 95.9(%)
not less than 60% 97.4(%)
not less than 50% 98.2(%)

* Iron Loss is accounted.