DP

Transient Magnetic (2D/Axisymmetric)

Sort condition
Newest first
Oldest first
Large number of views
  1. [RTML-033] PMSM/SPM Constant rating 100(kW) 3-phase

    Type: PMSM | Max Power: 100(kW) | Stator(Outside Diameter): 400(mm) | Height: 51(mm) | Voltage/Current: DC500(V)/400(A) | Rotor/Mover: SPM | Average torque: 176(N·m)

  2. [RTML-034] PMSM/IPM Constant rating 100(kW) 3-phase

    Type: PMSM | Max Power: 100(kW) | Stator(Outside Diameter): 400(mm) | Height: 89(mm) | Voltage/Current: DC500(V)/400(A) | Rotor/Mover: IPM(Vshaped) | Average torque: 178(N·m)

  3. [RTML-035] PMSM/IPM Constant rating 100(kW) 3-phase

    Type: PMSM | Max Power: 100(kW) | Stator(Outside Diameter): 400(mm) | Height: 81(mm) | Voltage/Current: DC500(V)/400(A) | Rotor/Mover: IPM(flat) | Average torque: 179(N·m)

  4. [RTML-036] PMSM/SPM Constant rating 100(kW) 3-phase

    Type: PMSM | Max Power: 100(kW) | Stator(Outside Diameter): 400(mm) | Height: 63(mm) | Voltage/Current: DC500(V)/400(A) | Rotor/Mover: SPM | Average torque: 179(N·m)

  5. [RTML-039] SOLENOID_01

    Type: SOLENOID | Voltage: DC12(V)

  6. [RTML-045] LSM_01

    Type: LSM | Max Power: 2(kW) | Voltage: DC400(V) | Rotor/Mover: SPM

  7. [JAC288] Synchronous Reluctance Motor Topology Optimization

    In this example, topology optimization is used to minimize the torque ripple and maximize the average torque when exploring the rotor geometry.

  8. [JFT132] Simultaneous Parameter and Topology Optimization

    This document describes the method for optimizing parameters and topology simultaneously.

  9. [JFT015] Procedure for Direct Coupled Analysis with JMAG and STAR-CCM+ Taking Thermal Fluid into Account (Ver.22.0 and After)

    This document presents the procedure for two way coupled analysis considering thermal fluid by using JMAG and STAR-CCM+.

  10. [JAC253] Analysis of an Induction Generator

    In this example, the relationship between the output power and efficiency of the induction generator is shown here.

  11. [RTML-051] WFSM_03

    Type: WFSM | Max Power: 10(kW) | Stator(Outside Diameter): 115(mm) | Height: 150(mm) | Voltage/Current: DC240(V)/84.8(A), DC300(V)/15(A) | Rotor/Mover: WF | Number of Phases: 3

  12. [JAC273] Creating IPM Motor Efficiency Maps Accounting for AC Loss

    In this example, an IPM motor efficiency map that accounts for AC loss from a PWM is created, and a comparison with an efficiency map that does not account for AC loss is performe…

  13. [RTML-052] WFSM_04

    Type: WFSM | Max Power: 10(kW) | Stator(Outside Diameter): 185(mm) | Height: 40(mm) | Voltage/Current: DC240(V)/84.8(A), DC300(V)/50(A) | Rotor/Mover: WF | Number of Phases: 3

  14. [RTML-053] WFSM_05

    Type: WFSM | Max Power: 10(kW) | Stator(Outside Diameter): 185(mm) | Height: 50(mm) | Voltage/Current: DC240(V)/84.8(A), DC300(V)/35(A) | Rotor/Mover: WF | Number of Phases: 3

  15. [RTML-054] WFSM_06

    Type: WFSM | Max Power: 75(kW) | Stator(Outside Diameter): 212(mm) | Height: 200(mm) | Voltage/Current: DC600(V)/250(A), DC200(V)/20(A) | Rotor/Mover: WF | Number of Phases: 3

  16. [RTML-055] WFSM_07

    Type: WFSM | Max Power: 75(kW) | Stator(Outside Diameter): 212(mm) | Height: 200(mm) | Voltage/Current: DC600(V)/250(A), DC600(V)/45(A) | Rotor/Mover: WF | Number of Phases: 3

Search Filter

  • All Categories

Remember me
Sign In
Create an account (Free) About authentication ID for JMAG website