DP
Transient Magnetic (2D/Axisymmetric)
- Sort condition
- Newest first
- Oldest first
- Large number of views
-
[RTML-060] IM Constant rating 100(kW)
Type: IM | Max Power: 100(kW) | Stator(Outside Diameter): 200(mm) | Height: 65(mm) | Voltage/Current: DC500(V)/600(A) | Rotor/Mover: Cage
-
[RTML-059] IM Constant rating 100(kW)
Type: IM | Max Power: 100(kW) | Stator(Outside Diameter): 125(mm) | Height: 259(mm) | Voltage/Current: DC600(V)/400(A) | Rotor/Mover: Cage
-
[RTML-058] IM Constant rating 10(kW)
Type: IM | Max Power: 10(kW) | Stator(Outside Diameter): 92.5(mm) | Height: 37(mm) | Voltage/Current: DC440(V)/200(A) | Rotor/Mover: Cage
-
[RTML-057] IM Constant rating 1(kW)
Type: IM | Max Power: 1(kW) | Stator(Outside Diameter): 57.5(mm) | Height: 20(mm) | Voltage/Current: DC100(V)/28.3(A) | Rotor/Mover: Cage
-
[RTML-056] WFSM_08
Type: WFSM | Max Power: 75(kW) | Stator(Outside Diameter): 400(mm) | Height: 65(mm) | Voltage/Current: DC500(V)/283(A), DC600(V)/50(A) | Rotor/Mover: WF | Number of Phases: 3
-
[RTML-055] WFSM_07
Type: WFSM | Max Power: 75(kW) | Stator(Outside Diameter): 212(mm) | Height: 200(mm) | Voltage/Current: DC600(V)/250(A), DC600(V)/45(A) | Rotor/Mover: WF | Number of Phases: 3
-
[RTML-054] WFSM_06
Type: WFSM | Max Power: 75(kW) | Stator(Outside Diameter): 212(mm) | Height: 200(mm) | Voltage/Current: DC600(V)/250(A), DC200(V)/20(A) | Rotor/Mover: WF | Number of Phases: 3
-
[RTML-053] WFSM_05
Type: WFSM | Max Power: 10(kW) | Stator(Outside Diameter): 185(mm) | Height: 50(mm) | Voltage/Current: DC240(V)/84.8(A), DC300(V)/35(A) | Rotor/Mover: WF | Number of Phases: 3
-
[RTML-052] WFSM_04
Type: WFSM | Max Power: 10(kW) | Stator(Outside Diameter): 185(mm) | Height: 40(mm) | Voltage/Current: DC240(V)/84.8(A), DC300(V)/50(A) | Rotor/Mover: WF | Number of Phases: 3
-
[JAC273] Creating IPM Motor Efficiency Maps Accounting for AC Loss
In this example, an IPM motor efficiency map that accounts for AC loss from a PWM is created, and a comparison with an efficiency map that does not account for AC loss is performe…
-
[RTML-051] WFSM_03
Type: WFSM | Max Power: 10(kW) | Stator(Outside Diameter): 115(mm) | Height: 150(mm) | Voltage/Current: DC240(V)/84.8(A), DC300(V)/15(A) | Rotor/Mover: WF | Number of Phases: 3
-
[JAC253] Analysis of an Induction Generator
In this example, the relationship between the output power and efficiency of the induction generator is shown here.
-
[JFT015] Procedure for Direct Coupled Analysis with JMAG and STAR-CCM+ Taking Thermal Fluid into Account (Ver.22.0 and After)
This document presents the procedure for two way coupled analysis considering thermal fluid by using JMAG and STAR-CCM+.
-
[JFT132] Simultaneous Parameter and Topology Optimization
This document describes the method for optimizing parameters and topology simultaneously.
-
[JAC288] Synchronous Reluctance Motor Topology Optimization
In this example, topology optimization is used to minimize the torque ripple and maximize the average torque when exploring the rotor geometry.
-
[RTML-045] LSM_01
Type: LSM | Max Power: 2(kW) | Voltage: DC400(V) | Rotor/Mover: SPM