- JMAG-RT Model(ControlRTBlock)
The control RT block
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
RTType Flag
1 or 3PhasePMSM
2 or 3PhaseInductionMotor
11 or 6PhasePMSM
12 or 3PhaseSynReluctanceMotor
13 or 6PhaseSynReluctanceMotor
15 or 6PhaseInductionMotorThe RT type
3-Phase PMSM
3-Phase Induction Motor
6-Phase PMSM
3-Phase Synchronous Reluctance Motor
6-Phase Synchronous Reluctance Motor
6-Phase Induction MotorRttFileName String the rtt file used for calculation
AccuracyType Flag
0 or LdLq(Table)
1 or SpatialHarmonics
2 or SpatialHarmonicsIntegralThe accuracy type
LdLq(Table).
Spatial Harmonics (Differential).
Spatial Harmonics (Integral).InputSignalType Flag
1 or Voltage
2 or CurrentThe input signal type
The voltage value.
The current value.InputSignalTable Table The input signal type table
IronLossFlag Flag
0 or IgnoreIronLoss
1 or IncludeIronLossThe flag of iron loss
Ignore Iron Loss.
Include Iron Loss.LossCalculationMethodFlag Flag
0 or UseFundamentalCurrent
1 or UseArbitraryCurrentThe flag of loss calculation method
Use Fundamental Current.
Use Arbitrary Current.FilterInductanceFlag Flag
0 or NotSpecifyFilterInductance
1 or SpecifyFilterInductanceThe flag of filter inductance
Use Filter Induction Value from RTT File.
Specify Filter Inductance.FilterInductance Double The filter inductance value
FilterInductance2 Double The filter inductance 2 value
SeriesParallelFlag Flag
0 or Series
1 or ParallelThe flag for series or parallel
Series Coil Connection.
Parallel Coil Connection.NumCoilsPerPhase Flag The number of coils per phase
UseRTTValues Flag
0 or DefaultValue
1 or RTTValueThe flag for using Default or RTT values
Use Default Values.
Use RTT Values.TemperatureFlag Flag
0 or IgnoreTemperature
1 or CalculateTemperatureThe flag of temperature
Ignore Temperature.
Calculate With Temperature.NumUSP Flag The number of USP ports
NumIronLoss Flag The number of iron loss ports
ACLossFlag Flag
0 or Off
1 or OnThe flag to use AC Loss
Not use AC Loss.
Use AC Loss.ConductorSlotHeight Double The number of conductors in slot height
ConductorSlotWidth Double The number of conductors in slot width
SlotsPerPhase Double The slots per phase
AverageSlotWidth Double The averaged slot width
ACLossConductorType Flag
0 or RectangularConductor
1 or RoundConductorThe AC loss conductor type
Rectangle
RoundConductorHeight Double The conductor height
ConductorWidth Double The conductor width
CoreStackLength Double The core stack length
ACLossConductivity Double The conductivity
OffsetAngle Double The offset angle value
OffsetLength Double The offset length value
ConnectionType Flag
0 or StarConnection
1 or DeltaConnection
2 or OpenEndWindingThe type of connection
Star Connection.
Delta Connection.
Open End Winding.NeutralPointFlag Flag
0 or Off
1 or OnThe flag of use neutral point
Not use neutral point.
Use neutral point.InductanceCorrection Double The inductance correction value
MagneticFluxCorrection Double The magnetic flux correction value
TorqueCorrection Double The torque correction value
MagnetGradeCorrection Double The magnet grade correction value
SteelGradeCorrection Double The steel grade correction value
Coil1TurnsCorrection Double Number of Turns Correction Value (Complex)
Coil2TurnsCorrection Double Number of Turns Correction Value (Current Reference)
ACLossCorrection Double The ac loss correction value
TemperatureCorrectionFlag Flag
0 or UseRTTTemp
1 or UseUserSetValueThe flag of temperature correction
Use temperature from RTT file.
Use temperature set by user.CorrectionCoefficientFlag Flag
0 or UseRTTCoefficient
1 or UseUserSetCoefficientThe flag of correction coefficient
Use coefficient from RTT file.
Use coefficient set by user.InterpolationFlag Flag
0 or UseLinearInterpolation
1 or UseUserSetInterpolationThe flag of interpolation method
Use linear interpolation.
Use interpolation set by user.CoilTemperatureCorrectionCoefficient Double The coil temperature correction value
MagnetTemperatureCorrectionCoefficient Double The magnet temperature correction value
CoilTemperatureCorrection Double The base temperature of temperature correction coefficient of coil value
MagnetTemperatureCorrection Double The base temperature of temperature correction coefficient of magnet value
ConductorTemperatureCorrectionCoefficient Double The conductor temperature correction value
ConductorTemperatureCorrection Double The base temperature of temperature correction coefficient of conductor value
InterpolationType Flag
0 or Linear
1 or CubicThe table data interpolation type
Linear Interpolation.
Cubic Interpolation.SkewCalculationFlag Flag
0 or NoSkewCalculation
1 or UseSkewCalculationThe flag of skew calculation
No skew calculation.
Use skew calculation.RotorSkewAngle Double The rotor skew angle value
RotorSkewType Flag
0 or NoSkew
1 or LinearSkew
2 or VSkew
3 or StepSkewThe rotor skew type
No skew.
Linear skew.
V skew.
Step skew.RotorSkewStep Flag The rotor skew step value
StatorSkewType Flag
0 or NoSkew
1 or LinearSkew
2 or VSkew
3 or StepSkewThe stator skew type
No skew.
Linear skew.
V skew.
Step skew.StatorSkewAngle Double The stator skew angle value
StatorSkewStep Flag The stator skew step value
GenericRttFileName String the rtt file used for reference
PhaseResistance Double The phase resistance value
FEMCoilResistanceTable Table The FEM coil phase resistance table
ResistorResistanceTable Table The resistor phase resistance table
InductanceTable Table The phase inductance table
CapacitanceTable Table The phase capacitance table
LinearOffsetTable Table The linear offset table
RotationalOffsetTable Table The rotational offset table
FEMCoilFluxCorrectionTable Table The Fem coil flux correction table
TorqueEMCorrectionTable Table The torque/electromagnetic correction table
UserSpecifiedCorrectionTable Table The user specified correction table
WindingCorrectionTable Table The winding correction table
TemperatureCoefficientTable Table The temperature coefficient table
FieldResistance Double The field resistance value
RTTPhaseResistanceFlag Flag
0 or UseGUIPhaseResistance
1 or UseRTTPhaseResistanceThe flag of RTT phase resistance
Use phase resistance from GUI.
Use phase resistance from RTT file.RTTFieldResistanceFlag Flag
0 or UseGUIFieldResistance
1 or UseRTTFieldResistanceThe flag of RTT field resistance
Use field resistance from GUI.
Use field resistance from RTT file.RTTOutputInductanceCSVFlag Flag
0 or NoOutputInductanceCSV
1 or OutputInductanceCSVThe flag of output inductance CSV
Do not output inductance to CSV file.
Output inductance to CSV file.UseVectorTerminalFlag Flag
0 or SingleControlTerminal
1 or VectorControlTerminalThe flag for using vector terminal
Single control terminal.
Vector control terminal.FieldCoilCorrection Double The Field Flux Correction Factor
FieldCoilTurnsCorrection Double The Turns of Field Coil Correction Factor
FieldCoilTemperatureCorrectionCoefficient Double Field Coil Temperature Correction Factor
FieldCoilTemperatureCorrection Double The Reference Temperature of Temperature Correction Coefficient of Field Coil
ForceCorrection Double The Force Correction Factor
SecondaryResistanceCorrectionCoefficient Double Secondary Resistance Correction Factor
MagnetizingInductanceCorrectionCoefficient Double Magnetizing Inductance Correction Factor
PrimaryLeakageCorrectionCoefficient Double Primary Leakage Correction Factor
SecondaryLeakageCorrectionCoefficient Double Secondary Leakage Correction Factor
AdditionalPrimaryLeakageInductance Double The additional primary leakage inductance value
AdditionalSecondaryLeakageInductance Double The additional secondary leakage inductance value
RTTTypeMethod Flag
0 or SpecifyRTTFile
1 or SpecifyEfficiencyMapThe method to specify RTT file
Specify RTT File.
Specify Efficiency Map Study.EfficiencyMapStudyName String The efficiency map study for RT block
RttPassword String The rtt file password
GenericRttPassword String The rtt generic file password