- Electric Potential Source(1 terminal)(VoltageSource)
Electric Potential Source(1 terminal)
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
FunctionType Flag
0 or PointArray
1 or Sin
2 or Exp
3 or Constant
4 or Pulse
5 or Step
7 or ExternalCircuitThe flag for function type.
The point array type.
The sin function type.
The expotential function type.
The constant type.
The pulse function type.
The step function type.
The external circuit type.XType Flag
1 or Time
2 or Angle
6 or Step
8 or Position
9 or UserSubAxis Type
Time Axis
Angle Axis
Step Axis
The motion direction axis.
Use user-subroutine.Periodic Flag
0 or On
1 or OffFlag for Periodic Iteration
Periodic Iteration
Non Periodic Iterationuserid Flag The user subroutine ID.
Time Table Voltage versus Time Table
Angle Table Voltage versus Angle Table
Step Table Voltage versus Step Table
Position Table The voltage vs displacement point array
UseVoltageManualSetting Flag
0 or Off
1 or OnUse voltage manual setting or not
Not using voltage manual setting
Using voltage manual settingVoltageAmplitude Double Pseudo steady state voltage amplitude
VoltagePhase Double Pseudo steady state voltage phase
- Three-phase Electric Potential Source(3PhaseVoltageSource)
Three-phase Electric Potential Source
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
XType Flag
1 or Time
2 or Angle
3 or StrokeX
4 or StrokeY
5 or StrokeZ
6 or Step
8 or PositionAxis Type
Time Axis
Angle Axis
The X component axis.
The Y component axis.
The Z component axis.
Step Axis
The motion direction axis.VoltageSpecifyType Flag
0 or UseTerminalPotential
1 or UseLineVoltageThe specified voltage type
Use terminal potential.
Use line voltage.VoltageValueType Flag
0 or UseAmplitude
1 or UseRMSPeak Type
Use amplitude.
Use rms.Amplitude Double Amplitude Value / RMS Value
Frequency Double Frequency
PhaseU Double Phase of U-Phase
CommutatingSequence Flag
0 or UVW
1 or UWVCommutating Sequence Type
The commutating sequence is U-V-W.
The commutating sequence is U-W-V.PeriodicStep Double The mechanical periodic step.
PeriodicAngle Double The mechanical periodic angle.
Stroke Double The periodic stroke.
- Multi Phase Electric Potential Source(MultiPhaseVoltageSource)
The multi phase voltage source
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
XType Flag
1 or Time
2 or Angle
3 or StrokeX
4 or StrokeY
5 or StrokeZ
6 or Step
8 or PositionAxis Type
Time Axis
Angle Axis
The X component axis.
The Y component axis.
The Z component axis.
Step Axis
The motion direction axis.NumPhases Flag The number of phases
PhaseWindingType Flag
0 or NPhaseWinding
1 or Multi3PhaseWindingThe phase winding type
Use N-phase electric potential source.
Use (N/3)x 3-phase electric potential source.VoltageValueType Flag
0 or UseAmplitude
1 or UseRMSPeak Type
Use amplitude.
Use rms.Amplitude Double Amplitude Value / RMS Value
Frequency Double Frequency
ReferencePhase Double The phase of U-Phase/1-Phase
PhaseDifference Double The phase difference
CommutatingSequence Flag
0 or UVW
1 or UWVCommutating Sequence Type
The commutating sequence is U-V-W.
The commutating sequence is U-W-V.PeriodicStep Double The mechanical periodic step.
PeriodicAngle Double The mechanical periodic angle.
Stroke Double The periodic stroke.
- Electric Potential Source(2 terminals)(TwoTerminalVoltageSource)
Electric Potential Source (2 terminals)
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
FunctionType Flag
0 or PointArray
1 or Sin
2 or Exp
3 or Constant
4 or Pulse
5 or Step
7 or ExternalCircuitThe flag for function type.
The point array type.
The sin function type.
The expotential function type.
The constant type.
The pulse function type.
The step function type.
The external circuit type.XType Flag
1 or Time
2 or Angle
6 or Step
8 or PositionAxis Type
Time Axis
Angle Axis
Step Axis
The motion direction axis.Periodic Flag
0 or On
1 or OffFlag for Periodic Iteration
Periodic Iteration
Non Periodic IterationTime Table Voltage versus Time Table
Angle Table Voltage versus Angle Table
Step Table Voltage versus Step Table
Position Table The voltage vs displacement point array
UseVoltageManualSetting Flag
0 or Off
1 or OnUse voltage manual setting or not
Not using voltage manual setting
Using voltage manual settingVoltageAmplitude Double Pseudo steady state voltage amplitude
VoltagePhase Double Pseudo steady state voltage phase
- Control Voltage Source(2 terminals)(ControlTwoTerminalVoltageSource)
The control two terminal voltage source
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
UseVoltageManualSetting Flag
0 or Off
1 or OnUse voltage manual setting or not
Not using voltage manual setting
Using voltage manual settingVoltageAmplitude Double Pseudo steady state voltage amplitude
VoltagePhase Double Pseudo steady state voltage phase
- Control Voltage Source(1 terminal)(ControlVoltageSource)
The control voltage source
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
UseVoltageManualSetting Flag
0 or Off
1 or OnUse voltage manual setting or not
Not using voltage manual setting
Using voltage manual settingVoltageAmplitude Double Pseudo steady state voltage amplitude
VoltagePhase Double Pseudo steady state voltage phase
- Power Source(PowerSource)
The power source
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
FunctionType Flag
0 or PointArray
1 or ConstantThe flag for function type.
The point array type.
The constant type.ConstantPower Double The constant power
PowerVsTime Table The power vs time point array
MaxVoltage Double The max voltage
MaxCurrent Double The max current
- Current Source(1 terminal)(CurrentSource)
Current Source(1 terminal)
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
FunctionType Flag
0 or PointArray
1 or Sin
2 or Exp
3 or Constant
4 or Pulse
5 or Step
7 or ExternalCircuit
8 or HarmonicThe flag for function type.
The point array type.
The sin function type.
The expotential function type.
The constant type.
The pulse function type.
The step function type.
The external circuit type.
The harmonic type.XType Flag
1 or Time
2 or Angle
6 or Step
8 or Position
9 or UserSubAxis Type
Time Axis
Angle Axis
Step Axis
The motion direction axis.
Use user-subroutine.Periodic Flag
0 or On
1 or OffFlag for Periodic Iteration
Periodic Iteration
Non Periodic Iterationuserid Flag The user subroutine ID.
Time Table Current versus Time Table
Angle Table Current versus Angle Table
Step Table Current versus Step Table
Position Table The current vs displacement point array
UseCurrentManualSetting Flag
0 or Off
1 or OnUse current manual setting or not
Not using current manual setting
Using current manual settingCurrentAmplitude Double Pseudo steady state current amplitude
CurrentPhase Double Pseudo steady state current phase
- Three-phase Current Source(3PhaseCurrentSource)
Three-phase Current Source
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
XType Flag
1 or Time
2 or Angle
3 or StrokeX
4 or StrokeY
5 or StrokeZ
6 or Step
8 or PositionAxis Type
Time Axis
Angle Axis
The X component axis.
The Y component axis.
The Z component axis.
Step Axis
The motion direction axis.CurrentValueType Flag
0 or UseAmplitude
1 or UseRMSPeak Type
Use amplitude.
Use rms.Amplitude Double Amplitude Value / RMS Value
Frequency Double Frequency
PhaseU Double Phase of U-Phase
CommutatingSequence Flag
0 or UVW
1 or UWVCommutating Sequence Type
The commutating sequence is U-V-W.
The commutating sequence is U-W-V.PeriodicStep Double The mechanical periodic step.
PeriodicAngle Double The mechanical periodic angle.
Stroke Double The periodic stroke.
- Multi Phase Current Source(MultiPhaseCurrentSource)
The multi phase current source
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
XType Flag
1 or Time
2 or Angle
3 or StrokeX
4 or StrokeY
5 or StrokeZ
6 or Step
8 or PositionAxis Type
Time Axis
Angle Axis
The X component axis.
The Y component axis.
The Z component axis.
Step Axis
The motion direction axis.NumPhases Flag The number of phases
PhaseWindingType Flag
0 or NPhaseWinding
1 or Multi3PhaseWindingThe phase winding type
Use N-phase current source.
Use (N/3)x 3-phase current source.CurrentValueType Flag
0 or UseAmplitude
1 or UseRMSPeak Type
Use amplitude.
Use rms.Amplitude Double Amplitude Value / RMS Value
Frequency Double Frequency
ReferencePhase Double The phase of U-Phase/1-Phase
PhaseDifference Double The phase difference
CommutatingSequence Flag
0 or UVW
1 or UWVCommutating Sequence Type
The commutating sequence is U-V-W.
The commutating sequence is U-W-V.PeriodicStep Double The mechanical periodic step.
PeriodicAngle Double The mechanical periodic angle.
Stroke Double The periodic stroke.
- Current Source(2 terminals)(TwoTerminalCurrentSource)
Current Source(2 terminals)
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
FunctionType Flag
0 or PointArray
1 or Sin
2 or Exp
3 or Constant
4 or Pulse
5 or Step
7 or ExternalCircuit
8 or HarmonicThe flag for function type.
The point array type.
The sin function type.
The expotential function type.
The constant type.
The pulse function type.
The step function type.
The external circuit type.
The harmonic type.XType Flag
1 or Time
2 or Angle
6 or Step
8 or PositionAxis Type
Time Axis
Angle Axis
Step Axis
The motion direction axis.Periodic Flag
0 or On
1 or OffFlag for Periodic Iteration
Periodic Iteration
Non Periodic IterationTime Table Current versus Time Table
Angle Table Current versus Angle Table
Step Table Current versus Step Table
Position Table The current vs displacement point array
UseCurrentManualSetting Flag
0 or Off
1 or OnUse current manual setting or not
Not using current manual setting
Using current manual settingCurrentAmplitude Double Pseudo steady state current amplitude
CurrentPhase Double Pseudo steady state current phase
- Control Current Source(2 terminals)(ControlTwoTerminalCurrentSource)
The control two terminal current source
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
UseCurrentManualSetting Flag
0 or Off
1 or OnUse current manual setting or not
Not using current manual setting
Using current manual settingCurrentAmplitude Double Pseudo steady state current amplitude
CurrentPhase Double Pseudo steady state current phase
- Control Current Source(1 terminal)(ControlCurrentSource)
The control current source
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
UseCurrentManualSetting Flag
0 or Off
1 or OnUse current manual setting or not
Not using current manual setting
Using current manual settingCurrentAmplitude Double Pseudo steady state current amplitude
CurrentPhase Double Pseudo steady state current phase
- Diode(Diode)
Diode
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
InitialVoltage Double Initial voltage
MaxResistance Double Maximum Resistance
MinResistance Double Minimum Resistance
k Double Coefficient k for Logarithm Function
SaturationCurrent Double Saturation Current
Type Flag
0 or PointArray
1 or FunctionThe flag for type.
The type is point array.
The type is function.voltage Table Current vs Voltage Table
- User Subroutine(UserSubroutine)
The user subroutine
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
UserParameter Flag The user parameter
- Switch(Switch)
Switch
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
InitialState Flag
0 or Off
1 or OnInitial state
The initial state is off.
The initial state is on.XType Flag
1 or Time
2 or Angle
6 or Step
8 or Position
11 or Current
12 or Voltage
13 or HysteresisAxis Type
Time Axis
Angle Axis
Step Axis
The motion direction axis.
The switch is current dependent.
The switch is voltage dependent.
The hysteresis band.reference Int Reference component
terminal1 Int Reference Probe 1
terminal2 Int Reference Probe 2
TimingType Flag
1 or PointArray
2 or Parameter
3 or ExternalCircuitThe flag for timing type.
The timing type is point array.
The timing type is parameter.
The timing type is external circuitPeriod Double One Period
t1 Double First Switching Time in One Period
t2 Double Second Switching Time in One Period
InitialOpenState Flag
0 or Off
1 or OnThe initial open state
The initial open state is off.
The initial open state is on.Time Table Time Table
Angle Table Angle Table
Step Table Step Table
Position Table The value vs displacement point array
Current Table The value vs current point array
Voltage Table The value vs voltage point array
Periodic Flag
0 or On
1 or OffFlag for Periodic Iteration
Periodic Iteration
Non Periodic IterationBandType Flag
0 or BaseWidth
1 or MaxMinThe hysteresis band type
Setting current base and current width.
Setting current max and current min.CurrentBase Double The hysteresis band current base
CurrentWidth Double The hysteresis band current width
CurrentMax Double The hysteresis band current max
CurrentMin Double The hysteresis band current min
- Control Switch(ControlSwitch)
The control switch
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
InitialState Flag
0 or Off
1 or OnInitial state
The initial state is off.
The initial state is on.
- FEA(FEAControlBlock)
The FEA control block
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
FEAReferenceStudy String The reference study for FEA block
- FEM Coil(Coil)
FEM Coil
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
Turn Double Number of Turns of the Coil
Resistance Double Resistance of the Coil
LeakageInductance Double The leakage inductance of the coil
Temperature Double The temperature
TempVsRes Table The resistor vs temperature point array
TimeVsTemp Table The temperature vs time point array
TemperatureDependentType Flag
0 or PointArray
1 or TemperatureDependentCorrectionResistance Setting Type
The point array type.
The temperture dependent correction type.BaseTemperatureResistance Double The base temperature resistance
BaseTemperature Double The base temperature
TemperatureCoefficient Double The temperature factor
AverageTemperatureName String The Average Temperature Name
XType Flag
9 or Temperature
10 or ConstantAxis Type
The temperature axis.
The constant axisTemperatureType Flag
0 or Constant
1 or PointSequence
2 or CouplingThe temperature type
The constant type
The point sequence type
The coupling type
- Reference FEM Coil(ReferenceCoil)
The reference coil
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
Reference Int The reference id
Periodic Flag
-1 or Reverse
1 or NormalThe periodic type
The reverse orientation
The basic orientation
- Three Terminal Coil(ThreeTerminalCoil)
The three terminal coil
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
Turn Double Number of Turns of the Coil
Resistance Double Resistance of the Coil
LeakageInductance Double The leakage inductance of the coil
TempVsRes Table The resistor vs temperature point array
TemperatureDependentType Flag
0 or PointArray
1 or TemperatureDependentCorrectionResistance Setting Type
The point array type.
The temperture dependent correction type.BaseTemperatureResistance Double The base temperature resistance
BaseTemperature Double The base temperature
TemperatureCoefficient Double The temperature factor
XType Flag
9 or Temperature
10 or ConstantAxis Type
The temperature axis.
The constant axis
- Coupling Control(CouplingControl)
The coupling control
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
NumberOfThermalCircuitCalcPerMag Flag The number of thermal circuit calculation per magnetic field analysis
UseAverageSteps Flag
0 or Off
1 or OnUse average steps for loss or not
Not using average steps for loss
Using average steps for lossAverageSteps Flag The average steps for loss
RunThermalMode Flag
0 or SyncThermal
1 or AfterThermalMethod of thermal circuit analysis
Thermal circuit analysis in synchronization with magnetic field analysis
Thermal circuit analysis after magnetic field analysisRunIronLoss Flag
0 or Off
1 or OnIron loss analysis in synchronization with magnetic field analysis
Do not perform iron loss analysis
Perform iron loss analysisPostProcessingSteps Flag Number of steps after post-processing
FrequencyPerOneMagAnalysis Flag The frequency for control analysis per one magnetic analysis
UnitForWhenToStartMag Flag
0 or TimeBeforeMagneticFieldAnalysis
1 or StepsBeforeMagneticFieldAnalysis
2 or SteadyStateMagneticFieldAnalysisUnit for when to start magnetic field analysis
Execute magnetic field analysis after specified time
Execute magnetic field analysis after specified steps
Execute magnetic field analysis after reaching steady stateStepToStartMag Flag Start magnetic field analysis after step
TimeToStartMag Double Start magnetic field analysis after time
SignalProbeReference Int Signal Probe reference id
SteadyStateFrequency Double Steady state frequency
SteadyStateTolerance Double Steady state tolerance
StopMagAnalysisFlag Flag
0 or UseStepControl
1 or UseSpecifiedTimeStop magnetic analysis flag
Use step control
Use user specified timePeriodToRunAnalysis Double Period to run analysis
SteadyStateStopCheckMethod Flag
0 or Maximum
1 or MovingAverageThe stop method used for the steady state
Maximum value
Moving average
- Brush / Commutator(BrushCommutator)
Brush Motor Component
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
BrushDivideMultiplier Flag The number of divider
Brushes Flag The number of brushes
Segments Flag Commutator Segments
BrushWidth Double Brush Width
SlitWidth Double Slit Width
InitialAngle Double Initial Angle
ContactResistance Double Contact Resistance between Brush and Commutator
UseArcVoltage Flag
0 or Off
1 or OnFlag to Allow Arc Voltage
Arc voltage is not used.
Arc voltage is used.ArcVoltage Double Arc Voltage
SparkoverVoltage Double Sparkover Voltage
EachBrush Flag
0 or Off
1 or OnThe flag to set detail
The all brush is set.
The each brush is set.UseResistanceTable Flag
0 or Off
1 or OnThe flag to allow resistance table
The resistance table is not used.
The resistance table is used.ContactAngleRatioVsAreaRatio Table The area ratio vs contact angle ratio point array
BrushWidth1 Double The brush1 width
ContactResistance1 Double The contact resistance between brush1 and commutator
UseBrushTable1 Flag
0 or Off
1 or OnThe flag to allow resistance table
The brush table1 is not used.
The brush table1 is used.ContactAngleRatioVsAreaRatio1 Table The area ratio vs contact angle ratio point array1
BrushPosition1 Double The Brush1 Position
BrushWidth2 Double The brush2 width
ContactResistance2 Double The contact resistance between brush2 and commutator
UseBrushTable2 Flag
0 or Off
1 or OnThe flag to allow resistance table
The brush table2 is not used.
The brush table2 is used.ContactAngleRatioVsAreaRatio2 Table The area ratio vs contact angle ratio point array2
BrushPosition2 Double The Brush2 Position
BrushWidth3 Double The brush3 width
ContactResistance3 Double The contact resistance between brush3 and commutator
UseBrushTable3 Flag
0 or Off
1 or OnThe flag to allow resistance table
The brush table3 is not used.
The brush table3 is used.ContactAngleRatioVsAreaRatio3 Table The area ratio vs contact angle ratio point array3
BrushPosition3 Double The Brush3 Position
BrushWidth4 Double The brush4 width
ContactResistance4 Double The contact resistance between brush4 and commutator
UseBrushTable4 Flag
0 or Off
1 or OnThe flag to allow resistance table
The brush table4 is not used.
The brush table4 is used.ContactAngleRatioVsAreaRatio4 Table The area ratio vs contact angle ratio point array4
BrushPosition4 Double The Brush4 Position
BrushWidth5 Double The brush5 width
ContactResistance5 Double The contact resistance between brush5 and commutator
UseBrushTable5 Flag
0 or Off
1 or OnThe flag to allow resistance table
The brush table5 is not used.
The brush table5 is used.ContactAngleRatioVsAreaRatio5 Table The area ratio vs contact angle ratio point array5
BrushPosition5 Double The Brush5 Position
BrushWidth6 Double The brush6 width
ContactResistance6 Double The contact resistance between brush6 and commutator
UseBrushTable6 Flag
0 or Off
1 or OnThe flag to allow resistance table
The brush table6 is not used.
The brush table6 is used.ContactAngleRatioVsAreaRatio6 Table The area ratio vs contact angle ratio point array6
BrushPosition6 Double The Brush6 Position
BrushWidth7 Double The brush7 width
ContactResistance7 Double The contact resistance between brush7 and commutator
UseBrushTable7 Flag
0 or Off
1 or OnThe flag to allow resistance table
The brush table7 is not used.
The brush table7 is used.ContactAngleRatioVsAreaRatio7 Table The area ratio vs contact angle ratio point array7
BrushPosition7 Double The Brush7 Position
BrushWidth8 Double The brush8 width
ContactResistance8 Double The contact resistance between brush8 and commutator
UseBrushTable8 Flag
0 or Off
1 or OnThe flag to allow resistance table
The brush table8 is not used.
The brush table8 is used.ContactAngleRatioVsAreaRatio8 Table The area ratio vs contact angle ratio point array8
BrushPosition8 Double The Brush8 Position
BrushWidth9 Double The brush9 width
ContactResistance9 Double The contact resistance between brush9 and commutator
UseBrushTable9 Flag
0 or Off
1 or OnThe flag to allow resistance table
The brush table9 is not used.
The brush table9 is used.ContactAngleRatioVsAreaRatio9 Table The area ratio vs contact angle ratio point array9
BrushPosition9 Double The Brush9 Position
BrushWidth10 Double The brush10 width
ContactResistance10 Double The contact resistance between brush10 and commutator
UseBrushTable10 Flag
0 or Off
1 or OnThe flag to allow resistance table
The brush table10 is not used.
The brush table10 is used.ContactAngleRatioVsAreaRatio10 Table The area ratio vs contact angle ratio point array10
BrushPosition10 Double The Brush10 Position
BrushWidth11 Double The brush11 width
ContactResistance11 Double The contact resistance between brush11 and commutator
UseBrushTable11 Flag
0 or Off
1 or OnThe flag to allow resistance table
The brush table11 is not used.
The brush table11 is used.ContactAngleRatioVsAreaRatio11 Table The area ratio vs contact angle ratio point array11
BrushPosition11 Double The Brush11 Position
BrushWidth12 Double The brush12 width
ContactResistance12 Double The contact resistance between brush12 and commutator
UseBrushTable12 Flag
0 or Off
1 or OnThe flag to allow resistance table
The brush table12 is not used.
The brush table12 is used.ContactAngleRatioVsAreaRatio12 Table The area ratio vs contact angle ratio point array12
BrushPosition12 Double The Brush12 Position
BrushWidth13 Double The brush13 width
ContactResistance13 Double The contact resistance between brush13 and commutator
UseBrushTable13 Flag
0 or Off
1 or OnThe flag to allow resistance table
The brush table13 is not used.
The brush table13 is used.ContactAngleRatioVsAreaRatio13 Table The area ratio vs contact angle ratio point array13
BrushPosition13 Double The Brush13 Position
BrushWidth14 Double The brush14 width
ContactResistance14 Double The contact resistance between brush14 and commutator
UseBrushTable14 Flag
0 or Off
1 or OnThe flag to allow resistance table
The brush table14 is not used.
The brush table14 is used.ContactAngleRatioVsAreaRatio14 Table The area ratio vs contact angle ratio point array14
BrushPosition14 Double The Brush14 Position
BrushWidth15 Double The brush15 width
ContactResistance15 Double The contact resistance between brush15 and commutator
UseBrushTable15 Flag
0 or Off
1 or OnThe flag to allow resistance table
The brush table15 is not used.
The brush table15 is used.ContactAngleRatioVsAreaRatio15 Table The area ratio vs contact angle ratio point array15
BrushPosition15 Double The Brush15 Position
BrushWidth16 Double The brush16 width
ContactResistance16 Double The contact resistance between brush16 and commutator
UseBrushTable16 Flag
0 or Off
1 or OnThe flag to allow resistance table
The brush table16 is not used.
The brush table16 is used.ContactAngleRatioVsAreaRatio16 Table The area ratio vs contact angle ratio point array16
BrushPosition16 Double The Brush16 Position
- Inductor(Inductor)
Inductor
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
Inductance Double Inductance
- Reference FEM Conductor(ReferenceConductor)
The reference conductor
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
Reference Int The reference id
Periodic Flag
-1 or Reverse
1 or NormalThe periodic type
The reverse orientation
The basic orientation
- Capacitor(Capacitor)
Capacitor
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
Capacitance Double Capacitance
- Resistor(Resistor)
Resistor
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
Resistance Double Resistance
XType Flag
1 or Time
2 or Angle
6 or Step
8 or Position
9 or Temperature
10 or Constant
11 or Current
12 or VoltageAxis Type
Time Axis
Angle Axis
Step Axis
The motion direction axis.
The temperature axis.
The constant axis.
The resistor is current dependent.
The resistor is voltage dependent.Periodic Flag
0 or On
1 or OffFlag for Periodic Iteration
Periodic Iteration
Non Periodic IterationTemperature Double The temperature
InitialResistance Double The initial resistance
reference Int Reference component
terminal1 Int Reference Probe 1
terminal2 Int Reference Probe 2
TimeVsRes Table The resistor vs time point array
StepVsRes Table The resistor vs step point array
AngleVsRes Table The resistor vs angle point array
DispVsRes Table The resistor vs displacement point array
TempVsRes Table The resistor vs temperature point array
TimeVsTemp Table The temperature vs time point array
CurrentVsRes Table The current resistor point array
VoltageVsRes Table The voltage resistor point array
AverageTemperatureName String The Average Temperature Name
TemperatureDependentType Flag
0 or PointArray
1 or TemperatureDependentCorrectionResistance Setting Type
The point array type.
The temperature dependent correction type.BaseTemperatureResistance Double The base temperature resistance
BaseTemperature Double The base temperature
TemperatureCoefficient Double The temperature factor
IncludeResistanceLoss Flag
0 or Off
1 or OnInclude resistance loss in circuit loss
Not including resistance loss in circuit loss.
Including resistance loss in circuit loss.TemperatureType Flag
0 or Constant
1 or PointArray
2 or CouplingThe flag of temperature setting type
The constant type
The point array type
The coupling type
- Three Terminal Resistor(ThreeTerminalResistor)
The three terminal resistor
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
Resistance Double Resistance
XType Flag
1 or Time
2 or Angle
6 or Step
8 or Position
9 or Temperature
10 or Constant
11 or Current
12 or VoltageAxis Type
Time Axis
Angle Axis
Step Axis
The motion direction axis.
The temperature axis.
The constant axis.
The resistor is current dependent.
The resistor is voltage dependent.Periodic Flag
0 or On
1 or OffFlag for Periodic Iteration
Periodic Iteration
Non Periodic IterationInitialResistance Double The initial resistance
reference Int Reference component
terminal1 Int Reference Probe 1
terminal2 Int Reference Probe 2
TimeVsRes Table The resistor vs time point array
StepVsRes Table The resistor vs step point array
AngleVsRes Table The resistor vs angle point array
DispVsRes Table The resistor vs displacement point array
TempVsRes Table The resistor vs temperature point array
CurrentVsRes Table The current resistor point array
VoltageVsRes Table The voltage resistor point array
TemperatureDependentType Flag
0 or PointArray
1 or TemperatureDependentCorrectionResistance Setting Type
The point array type.
The temperature dependent correction type.BaseTemperatureResistance Double The base temperature resistance
BaseTemperature Double The base temperature
TemperatureCoefficient Double The temperature factor
IncludeResistanceLoss Flag
0 or Off
1 or OnInclude resistance loss in circuit loss
Not including resistance loss in circuit loss.