- Study Properties(Control2D)
Control2D properties
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
FullModelConversion Flag
0 or Off
1 or OnFlag for Conversion to Value in Full Model
The result is not converted as a full model.
The result is converted as a full model.ConversionFactor Double Conversion factor excluding periodic boundary
ModelThickness Double Thickness of the Model
ManualCoilLength Flag
0 or Off
1 or OnFlag of Independent Length of the Coil from Thickness of the Model
The length of FEM coil is independent from the thickness of the model.
The length of FEM coil is equal to the thickness of the model.CoilLength Double Length of the FEM Coil
Coupling Flag
0 or Off
1 or OnFlag for Coupled Analysis
Do not run the Coupled Analysis.
Run the coupled analysis.CoupledRemesh Flag
0 or Off
1 or OnThe flag for coupled remesh region
The region is not coupled remesh.
The air region is coupled remesh.ConversionType Flag
0 or NotUse
1 or Periodic
2 or SeriesParallelThe flag of circuit conversion type
The circuit conversion is not used.
The periodic conversion type
The circuit conversion type for series/parallelCircuitConversionFactor Double The conversion factor of circuit
CircuitConnect Flag
0 or Series
1 or Parallel
2 or AntiParallelThe circuit connect information
The series type
The parallel type
The anti parallel typePowerCalcTolerance Double The power calculation tolerance
PowerCalcInitialCurrent Double The power calculation initial current
PowerCalcMaxIteration Flag The calculation max iteration
Series Double The number of series
Parallel Double The number of parallel
ConnectionMode Flag
0 or ModifiedNodal
1 or ClosedLoopThs circuit analysis method
The modified nodal analysis type
The closed loop current analysis typeUseWindingFactor Flag
0 or Off
1 or OnThe flag of use conversion factors from winding
Set conversion factors manually
Set conversion factors from windingUseForceCorrection Flag
0 or Off
1 or OnThe Force Correction
The force correction is not used.
The force correction is used.SymmetryPlane1 Coordinate The symmetry plane 1 for the force correction
CalculationMethod Flag
0 or Direct
2 or IterativeFlag of Calculation Method Type
Use FEM+BEM calculation method.
Use FEM calculation method.ApproximateTransientAnalysis Flag
0 or Off
1 or OnThe flag for use steady-state approximate transient analysis
Do not use steady-state approximate transient analysis
Use steady-state approximate transient analysisSpecifySlip Flag
0 or Off
1 or OnThe flag for stationary device or induction motor
Set as stationary device.
User can specify slip as induction motor.SteadyLinear Flag
0 or Nonlinear
1 or LinearThe flag to control non-linear type for pseudo steady state analysis.
Use conventional method of quasi steady state analysis.
Use fast acceleration of quasi-steady state analysis.Slip Double Slip value(s <= 1)
OutputSteadyResultAs1stStep Flag
0 or Off
1 or OnThe flag for output steady result as 1st step
Do not output steady result as 1st step
Output steady result as 1st stepSetPseudoSteadyStateFreq Flag
0 or Off
1 or OnThe flag for setting pseudo-steady state frequency
Do not use frequency for pseudo steady-state
Use frequency for pseudo steady-statePseudoSteadyStateFrequency Double pseudo steady-state frequency
SetUseCorrectBHCurve Flag
0 or Off
1 or OnThe flag for using correct bh curve for pseudo-steady state
Do not use correct bh curve for pseudo steady-state
Use correct bh curve for pseudo steady-stateTimePeriodicEEC Flag
0 or Off
1 or OnThe flag for time periodic explicit error correction
The time periodic explicit error correction is not executed.
The time periodic explicit error correction is executed.TimePeriodicType Flag
1 or AntiPeriodic
2 or PeriodicThe flag of time periodic type
Anti-Periodic
PeriodicReversePeriodic Flag
0 or Off
1 or OnThe flag reverse periodic rotor
The reverse periodic rotor is not used.
The reverse periodic rotor is used.UseRelaxation Flag
0 or Off
1 or OnThe flag use non-linear relaxation
Non-linear relaxation is not used
Use non-linear relaxation.CorrectionType Flag
0 or frequency
1 or stepThe flag for correction type
The correction type is frequency.
The correction type is step.CorrectionFrequency Double Frequency of correction
CorrectionInterval Flag Interval of correction step
MaxCorrections Flag Max number of correction process
FailureConvergenceError Flag
0 or Off
1 or OnThe flag to handle the failure of convergence as an error
Warning.
Error(Solver will terminate).ShortenCorrectionInterval Flag
0 or Off
1 or OnThe flag for shortening interval check
Do usual interval check.
Shorten interval check.AllStepsTransientCalculation Flag
0 or Off
1 or OnThe flag for calculate and output all steps of transient calculation
Do not calculate and output all steps of transient calculation.
Calculate and output all steps of transient calculation.UseGPU Flag
0 or Off
1 or OnThe flag for use GPU
Not use GPU.
Use GPU.RestartType Flag
0 or NotRestart
1 or FromTR
2 or FromFQThe restart type
Do not use restart.
Restart from transient analysis
Restart from frequency analysisRestartSavFile String The sav file for restart
RestartMsvFile String The msv file for restart
RestartSvcFile String The svc file for restart
DirectSolverType Flag
0 or ICCG
1 or Direct
2 or AutoThe flag of linear solver type
ICCG
Direct solver
AutoIccgAccel Double Value of Acceleration Coefficient
AutoAccel Flag
0 or Off
1 or OnFlag to Set Acceleration Coefficient Automatically
The acceleration coefficient is set in manual.
The acceleration coefficient is automatically set.ICCGToleranceType Flag
1 or Automatic
2 or Constant
4 or ScaleIndependentFlag of ICCG Calculation Type
The ICCG tolerance is scaled using the original matrix right hand side vector. The tolerance is then adjusted automatically at each iteration.
The same ICCG tolerance is used for all NR iterations and is scaled using the original matrix right hand side vector.
The ICCG tolerance is scaled by the residual independently for each matrix solution.InitialTolerance Double Value of Initial Convergence Tolerance
MinimumTolerance Double Value of Minimum Convergence Tolerance.
IccgTolerance Double Value of Convergence Tolerance
IccgLimit Double Value of Divergence Limit
IccgMaxIteration Flag Value of Maximum Iteration
IccgToleranceScaleIndependent Double The value of convergence tolerance.(Scale independent)
IccgOptimumValue Flag
0 or Off
1 or OnFlag of Convergence Refinement
No Refinement
Optimum RefinementNonlinearMethod Flag
0 or Newton-Raphson
1 or SuccessiveIterationNonlinear Iterative Calculation Type
Newton-Raphson
Successive IterationConvergenceType Flag
0 or Solution
1 or ResidualVector
2 or MagneticFluxDensityAndCircuit
3 or SolutionExcludingCircuit
4 or ResidualVectorExcludingCircuit
5 or MagneticFluxDensityConvergence determination type
Using Variation of Solution
Using Magnitude of Residual Vector
Using Variation of Magnetic Flux Density and Circuit Variables
Using Variation of Solution (Excluding Circuit Variables)
Using Magnitude of Residual Vector (Excluding Circuit Variables)
Using Variation of Magnetic Flux DensityRelaxationFactor Flag
0 or Off
1 or Type1
2 or Type2
5 or FactorAutoFlag of Relaxation Factor Type
No Relaxation
Relaxation Type 1
The relaxation type2
The relaxation autoNonlinearMaxIteration Flag Number of Nonlinear Iteration
NonlinearTolerance Double Value of Nonlinear Iterative Convergence Tolerance
NonlinearConvergenceB Flag
0 or Off
1 or OnThe maximum amount of change flag of the magnetic flux density
Not set the maximum amount of change in the magnetic flux density
To set the maximum amount of change in the magnetic flux densityNonlinearConvergenceV Flag
0 or Off
1 or OnThe maximum amount of change flag of the voltage
Not set the maximum amount of change in the voltage
To set the maximum amount of change in the voltageNonlinearConvergenceI Flag
0 or Off
1 or OnThe maximum amount of change flag of the current
Not set the maximum amount of change in the current
To set the maximum amount of change in the currentNonlinearConvergenceToleranceB Double The maximum amount of change in the magnetic flux density
NonlinearConvergenceToleranceV Double The maximum amount of change in the voltage
NonlinearConvergenceToleranceI Double The maximum amount of change in the current
NonlinearStrictConvergence Flag
0 or Off
0 or Off
1 or On
1 or OnFlag of Strict Judgment of Nonlinear Iterative Calculation
Normal judgment for convergence of nonlinear
Normal judgment for convergence of nonlinear
Strict judgment for convergence of nonlinear
Strict judgment for convergence of nonlinearNonlinearSpeedup Flag
0 or Off
1 or OnFlag of Using Nonlinear Speeding-up Function
Do not use speeding up nonlinear calculation.
Use speeding up nonlinear calculation.BHCorrection Flag
0 or Off
1 or OnFlag for applying a correction to the BH curve for frequency response analysis.
Do not apply BH curve correction.
Use BH curve correction.MagneticFluxDensity Flag
0 or Off
1 or OnThe flag for output magnetic flux density result
Not output the magnetic flux density.
Output the magnetic flux density.Magnetization Flag
0 or Off
1 or OnThe flag for output magnetization
Not output the magnetization.
Output the magnetization.PermeanceFactor Flag
0 or Off
1 or OnThe flag for output permeance factor
Not output the permeance factor.
Output the permeance factor.Permeability Flag
0 or Off
1 or OnThe flag for output permeability
Not output the permeability.
Output the permeability.DifferentialPermeability Flag
0 or Off
1 or OnThe flag for output differential permeability
Not output the differential permeability.
Output the differential permeability.CurrentDensity Flag
0 or Off
1 or OnThe flag for output current density result
Not output the current density.
Output the current density.LossDensity Flag
0 or Off
1 or OnThe flag for output loss density
Not output the loss density.
Output the loss density.Displacement Flag
0 or Off
1 or OnThe flag for output nodal displacement result
Not output the nodal displacement.
Output the nodal displacement.NodalForce Flag
0 or Off
1 or OnThe flag for output nodal force result
Not output the nodal force.
Output the nodal force.SurfaceForceDensity Flag
0 or Off
1 or OnThe flag for surface force density
Not output the surface force density.
Output the surface force density.LorentzForceDensity Flag
0 or Off
1 or OnThe flag for output Lorentz force density
Not output the Lorentz force density.
Output the lorentz force density.VectorPotential Flag
0 or Off
1 or OnThe flag for output vector potential
Not output the vector potential.
Output the vector potential.Energy Flag
0 or Off
1 or OnThe flag for output energy result
Not output the energy.
Output the energy.Stress Flag
0 or Off
1 or OnThe flag for output stress result
Not output the stress.
Output the stress.DemagnetizationRatio Flag
0 or Off
1 or OnThe flag for output demagnetization ratio (Compared to reference step)
Not output the Demagnetization ratio (Compared to reference step).
Output the Demagnetization ratio (Compared to reference step).DemagnetizationRatioDiffUnDemag Flag
0 or Off
1 or OnThe flag for output demagnetization ratio (Compared to undemagnetized state)
Not output the Demagnetization ratio (Compared to undemagnetized state).
Output the Demagnetization ratio (Compared to undemagnetized state).HysteresisLossDensity Flag
0 or Off
1 or OnThe flag for output hysteresis loss density
Not output the hysteresis loss density
Output the hysteresis loss densityRestartFile Flag
0 or Off
1 or OnThe flag for output restart file
Not output the restart file.
Output the restart file.RestartFileOutputInterval Flag The minimum output interval(minute) for restart file
JCGMonitor Flag
0 or Off
1 or OnThe flag for output ICCG Iteration Count Monitoring file.
Not output the JCG monitor.
Output the JCG monitor.SolverReportFile Flag
0 or Off
1 or OnThe flag for output solver report file
Not output the solver report file.
Output the solver report file.InitialMagnetization Flag
0 or Off
1 or OnThe flag for initial magnetization
Not output the initial magnetization.
Output the initial magnetization.CoerciveForceNormal Flag
0 or Off
1 or OnThe flag to control output of normalized Coercive Force
Do not output the normalized coercive force.
Output the normalized coercive force.MagnetizationRatio Flag
0 or Off
1 or OnThe flag to control output of magnetization ratio
Do not output the magnetization ratio.
Output the magnetization ratio.Temperature Flag
0 or Off
1 or OnThe flag for output temperature
Not output the temperature.
Output the temperature.IronLossDensity Flag
0 or Off
1 or OnThe flag for output iron loss density
Not output the ironloss density.
Output the ironloss density.ElectricField Flag
0 or Off
1 or OnThe flag for output electric field result
Not output the electric field.
Output the electric field.MagneticFluxDensityLamination Flag
0 or Off
1 or OnThe flag to output lamination magnetic flux density
Not output the lamination magnetic flux density
Output the lamination magnetic flux densityMagneticFieldStrengthLamination Flag
0 or Off
1 or OnThe flag to output lamination magnetic field strength
Not output the lamination magnetic field strength
Output the lamination magnetic field strengthEddyCurrentDensityLamination Flag
0 or Off
1 or OnThe flag to output lamination eddy current density
Not output the lamination eddy current density
Output the lamination eddy current densityCurrentLossDensityLamination Flag
0 or Off
1 or OnThe flag to output lamination current loss density
Not output the lamination current loss density
Output the lamination current loss densityHysteresisLossDensityLamination Flag
0 or Off
1 or OnThe flag to output lamination hysteresis loss density
Not output the lamination hysteresis loss density
Output the lamination hysteresis loss densityCriticalCurrentDensity Flag
0 or Off
1 or OnThe flag to output critical current density
Not output the critical current density
Output the critical current densityIronRefMagneticFluxDensity Flag
0 or Off
1 or OnThe flag for output reference magnetic flux density result (Iron)
Not output the reference magnetic flux density (Iron)
Output the reference magnetic flux density (Iron)IronIronLossDensity Flag
0 or Off
1 or OnThe flag for output iron loss density (Iron)
Not output the iron loss density (Iron)
Output the iron loss density (Iron)IronHysteresisLossDensity Flag
0 or Off
1 or OnThe flag for output hysteresis loss density (Iron)
Not output the hysteresis loss density (Iron)
Output the hysteresis loss density (Iron)IronExcessEddyCurrentDensity Flag
0 or Off
1 or OnThe flag for output excess eddy current loss density (Iron)
Not output the excess eddy current loss density (Iron)
Output the excess eddy current loss density (Iron)IronClassicalEddyCurrentDensity Flag
0 or Off
1 or OnThe flag for output classical eddy current loss density (Iron)
Not output the classical eddy current loss density (Iron)
Output the classical eddy current loss density (Iron)IronJouleLossDensity Flag
0 or Off
1 or OnThe flag for output Joule loss density (Iron)
Not output the Joule loss density (Iron)
Output the Joule loss density (Iron)IronStress Flag
0 or Off
1 or OnThe flag for output stress result (Iron)
Not output the stress (Iron)
Output the stress (Iron)IronMagneticFluxDensityLamination Flag
0 or Off
1 or OnThe flag to output lamination magnetic flux density (Iron)
Not output the lamination magnetic flux density (Iron)
Output the lamination magnetic flux density (Iron)IronMagneticFieldStrengthLamination Flag
0 or Off
1 or OnThe flag to output lamination magnetic field strength (Iron)
Not output the lamination magnetic field strength (Iron)
Output the lamination magnetic field strength (Iron)IronEddyCurrentDensityLamination Flag
0 or Off
1 or OnThe flag to output lamination eddy current density (Iron)
Not output the lamination eddy current density (Iron)
Output the lamination eddy current density (Iron)IronCurrentLossDensityLamination Flag
0 or Off
1 or OnThe flag to output lamination current loss density (Iron)
Not output the lamination current loss density (Iron)
Output the lamination current loss density (Iron)IronHysteresisLossDensityLamination Flag
0 or Off
1 or OnThe flag to output lamination hysteresis loss density (Iron)
Not output the lamination hysteresis loss density (Iron)
Output the lamination hysteresis loss density (Iron)OutputTimingMode Flag
0 or Off
1 or FromStep
1 or On
2 or SpecifyIntervalA flag to control timing of output to plot file
Always output from 1st step.
Output from step specified in OutputStartStep.
Output from step specified in OutputStartStep.
Output from step specified Interval.OutputStartStep Flag The first step to use for the output
MinimizeResults Flag
0 or Off
1 or OnFlag to control minimization of output results
Do not minimize output of distributed results for output control
Minimize output of distributed results for output controlOutputIntervalTable Table output control interval table
OutputTimingSameStep Flag
0 or Off
1 or OnFlag to use same step by table and field results
Output another step by table and field results
Output same step by table and field resultsOutputResultsTimingMode Flag
0 or Off
1 or FromStep
1 or On
2 or SpecifyInterval
3 or NoOutputFlag to control step output to result file
Output all steps
Output from step specified by OutputResultStartStep
Output from step specified by OutputResultStartStep
Output from step specified Interval
No OutputOutputResultsStartStep Flag The first step to use for the output
OutputResultsIntervalTable Table output control interval table
Hsusr1 Flag
0 or Off
1 or OnFlag of User Subroutine "hsusr1"
Do Not Use User Subroutine "hsusr1"
Use User Subroutine "hsusr1"Hsusr3 Flag
0 or Off
1 or OnFlag of User Subroutine "hsusr3"
Do Not Use User Subroutine "hsusr3"
Use User Subroutine "hsusr3"Hsusr4 Flag
0 or Off
1 or OnFlag of User Subroutine "hsusr4"
Do Not Use User Subroutine "hsusr4"
Use User Subroutine "hsusr4"Usrfle Flag
0 or Off
1 or OnFlag of User Subroutine "usrfle"
Do Not Use User Subroutine "usrfle"
Use User Subroutine "usrfle"Usrstp Flag
0 or Off
1 or OnFlag of User Subroutine "usrstp"
Do Not Use User Subroutine "usrstp"
Use User Subroutine "usrstp"Usrlos Flag
0 or Off
1 or OnFlag of User Subroutine "usrlos"
Do Not Use User Subroutine "usrlos"
Use User Subroutine "usrlos"Usrhys Flag
0 or Off
1 or OnFlag of User Subroutine "usrhys"
Do Not Use User Subroutine "usrhys"
Use User Subroutine "usrhys"Usrfm2 Flag
0 or Off
1 or OnFlag of User Subroutine "usrfm2"
Do Not Use User Subroutine "usrfm2"
Use User Subroutine "usrfm2"Usrfma Flag
0 or Off
1 or On
2 or usrfm3The flag of user subroutine "usrfma"
Not use user subroutine "usrfma"
Use user subroutine "usrfma"
Use user subroutine "usrfm3"Usrstr Flag
0 or Off
1 or OnThe flag of user subroutine "usrstr"
Not use user subroutine "usrstr"
Use user subroutine "usrstr"UsrArraySize Flag The size of users subroutine point array
UsrsubName String User Subroutine Name
Snapshot Flag
0 or Off
1 or OnThe flag for Snapshot
Not use Snapshot
Use SnapshotRetry Flag Number of retries
Divisions Flag Number of steps divided
Monitor Flag
0 or Off
1 or OnThe flag to output monitoring file during analysis execution
Do not output the monitoring file during analysis execution
Output a monitoring file during analysis executionCsvOutputPath String The output path for the csv files
CsvResultTypes String The list of result types to output the csv files
CsvOutputResponseData Flag CSV file output response value
CsvOutputInductanceData Flag CSV file output efficiency map inductance values
CsvOutputProbe Flag CSV file output probe value
CsvOutputSection Flag CSV file output section graph value
CsvOutputCalculation Flag CSV file output calculation value
CsvOutputObjectiveData Flag CSV file output objective value
CsvComponentType Flag
0 or RealImaginary
1 or AmplitudePhase
2 or RMSFlag of component output type
Output real and imaginary
Output amplitude and phase
Output rmsCsvDivisionType Flag
0 or Off
1 or OnFlag of divide CSV file output by specified number of cases
Do not divide
Divide CSV outputCsvDivisionCase Flag Specified number of cases
OutputControlType Flag
0 or SpecifyOutputResultItems
1 or OutputTableOnly
2 or DeleteResultFilesThe output control type
Specify Result Items to be Output.
Output only table results.
Delete result files.LogOutputLevel Flag
0 or Debug
1 or Information
2 or Warning
3 or ErrorThe log output level
Debug
Information
Warning
Error
- SteadyState(SteadyState)
-
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
SteadyStateStopCheckMethod Flag
0 or Maximum
1 or Instantaneous
2 or Average
3 or FrequencyThe stop method used for the steady state
Maximum value
Instantaneous Value
Average Value
Frequency ComponentSteadyStatePeriodic Double The Periodic used to determine steady state
SteadyStateFrequency Double The frequency used to determine steady state
HarmonicOrder Flag Harmonic Order
SteadyStateThreshold Double The threshold used for the steady state
SteadyStatePhaseThreshold Double The phase threshold used for the steady state
UsePhaseStationary Flag
0 or Off
1 or OnUse phase stationary
Do not use phase stationary
Use phase stationarySteadyStateReferenceResultSource Flag
1 or Torque
2 or Force
3 or FEMCoil
4 or FEMConductor
5 or CurrentCondition
6 or FluxCondition
7 or MotionDisplacement
8 or MotionSpeed
9 or Loss
10 or Voltage
11 or Current
12 or ControlSignal
13 or TemperatureThe type of result used for the steady state
Torque results
Force results
FEM Coil (Flux)
FEM Conductor (Flux)
Current Condition (Flux)
Flux Condition (Flux)
Motion (displacement)
Motion (speed)
Loss value
Voltage probe
Current probe
Control signal probe
Temperature probeSteadyStateVoltageProbe Int Voltage probe for steady state
SteadyStateCircuitCurrent Int Circuit component for current for steady state
SteadyStateControleProbe Int Control probe for steady state
SteadyStateTemperatureProbe Int Temperature probe for steady state
SteadyStateResultComponent Flag
0 or Absolute
1 or First
2 or Second
3 or ThirdThe component of the result used for the steady state
Absolute value of the result
The first (X) component
The second (Y) component
The third (Z) componentSteadyStateLinkedTorque Int Linked torque condition for steady state
SteadyStateLinkedForce Int Linked force condition for steady state
SteadyStateLinkedCoil Int Linked FEM Coil for steady state
SteadyStateLinkedConductor Int Linked FEM Conductor for steady state
SteadyStateLinkedCurrent Int Linked current condition for steady state
SteadyStateLinkedFlux Int Linked flux condition for steady state
SteadyStateLinkedDisplacement Int Linked motion displacement for steady state
SteadyStateLinkedSpeed Int Linked motion speed for steady state
- Study Properties(Control)
Control properties
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
FullModelConversion Flag
0 or Off
1 or OnFlag for Conversion to Value in Full Model
The result is not converted as a full model.
The result is converted as a full model.ConversionFactor Double Conversion factor excluding periodic boundary
Coupling Flag
0 or Off
1 or OnFlag for Coupled Analysis
Do not run the Coupled Analysis.
Run the coupled analysis.CoupledRemesh Flag
0 or Off
1 or OnThe flag for coupled remesh region
The region is not coupled remesh.
The air region is coupled remesh.ConversionType Flag
0 or NotUse
1 or Periodic
2 or SeriesParallelThe flag of circuit conversion type
The circuit conversion is not used.
The periodic conversion type
The circuit conversion type for series/parallelCircuitConversionFactor Double The conversion factor of circuit
CircuitConnect Flag
0 or Series
1 or Parallel
2 or AntiParallelThe circuit connect information
The series type
The parallel type
The anti parallel typePowerCalcTolerance Double The power calculation tolerance
PowerCalcInitialCurrent Double The power calculation initial current
PowerCalcMaxIteration Flag The calculation max iteration
Series Double The number of series
Parallel Double The number of parallel
ConnectionMode Flag
0 or ModifiedNodal
1 or ClosedLoopThs circuit analysis method
The modified nodal analysis type
The closed loop current analysis typeUseWindingFactor Flag
0 or Off
1 or OnThe flag of use conversion factors from winding
Set conversion factors manually
Set conversion factors from windingUseForceCorrection Flag
0 or Off
1 or OnThe Force Correction
The force correction is not used.
The force correction is used.SymmetryPlane1 Coordinate The symmetry plane 1 for the force correction
SymmetryPlane2 Coordinate The symmetry plane 2 for the force correction
ApproximateTransientAnalysis Flag
0 or Off
1 or OnThe flag for use steady-state approximate transient analysis
Do not use steady-state approximate transient analysis
Use steady-state approximate transient analysisSpecifySlip Flag
0 or Off
1 or OnThe flag for stationary device or induction motor
Set as stationary device.
User can specify slip as induction motor.SteadyLinear Flag
0 or Nonlinear
1 or LinearThe flag to control non-linear type for pseudo steady state analysis.
Use conventional method of quasi steady state analysis.
Use fast acceleration of quasi-steady state analysis.Slip Double Slip value(s <= 1)
OutputSteadyResultAs1stStep Flag
0 or Off
1 or OnThe flag for output steady result as 1st step
Do not output steady result as 1st step
Output steady result as 1st stepSetPseudoSteadyStateFreq Flag
0 or Off
1 or OnThe flag for setting pseudo-steady state frequency
Do not use frequency for pseudo steady-state
Use frequency for pseudo steady-statePseudoSteadyStateFrequency Double pseudo steady-state frequency
SetUseCorrectBHCurve Flag
0 or Off
1 or OnThe flag for using correct bh curve for pseudo-steady state
Do not use correct bh curve for pseudo steady-state
Use correct bh curve for pseudo steady-stateTimePeriodicEEC Flag
0 or Off
1 or OnThe flag for time periodic explicit error correction
The time periodic explicit error correction is not executed.
The time periodic explicit error correction is executed.TimePeriodicType Flag
1 or AntiPeriodic
2 or PeriodicThe flag of time periodic type
Anti-Periodic
PeriodicReversePeriodic Flag
0 or Off
1 or OnThe flag reverse periodic rotor
The reverse periodic rotor is not used.
The reverse periodic rotor is used.UseRelaxation Flag
0 or Off
1 or OnThe flag use non-linear relaxation
Non-linear relaxation is not used
Use non-linear relaxation.CorrectionType Flag
0 or frequency
1 or stepThe flag for correction type
The correction type is frequency.
The correction type is step.CorrectionFrequency Double Frequency of correction
CorrectionInterval Flag Interval of correction step
MaxCorrections Flag Max number of correction process
FailureConvergenceError Flag
0 or Off
1 or OnThe flag to handle the failure of convergence as an error
Warning.
Error(Solver will terminate).CalculateDisplacementCurrentInAir Flag
0 or Off
1 or OnThe flag to control calculation of displacement currents in air regions
Do not calculate displacement currents in air regions.
Calculate displacement currents in air regions.ShortenCorrectionInterval Flag
0 or Off
1 or OnThe flag for shortening interval check
Do usual interval check.
Shorten interval check.AllStepsTransientCalculation Flag
0 or Off
1 or OnThe flag for calculate and output all steps of transient calculation
Do not calculate and output all steps of transient calculation.
Calculate and output all steps of transient calculation.UseGPU Flag
0 or Off
1 or OnThe flag for use GPU
Not use GPU.
Use GPU.RestartType Flag
0 or NotRestart
1 or FromTR
2 or FromFQThe restart type
Do not use restart.
Restart from transient analysis
Restart from frequency analysisRestartSavFile String The sav file for restart
RestartMsvFile String The msv file for restart
RestartSvcFile String The svc file for restart
DirectSolverType Flag
0 or ICCG
1 or DirectThe flag of linear solver type
ICCG
Direct solverIccgAccel Double Value of Acceleration Coefficient
AutoAccel Flag
0 or Off
1 or OnFlag to Set Acceleration Coefficient Automatically
The acceleration coefficient is set in manual.
The acceleration coefficient is automatically set.ICCGToleranceType Flag
1 or Automatic
2 or Constant
4 or ScaleIndependentFlag of ICCG Calculation Type
The ICCG tolerance is scaled using the original matrix right hand side vector. The tolerance is then adjusted automatically at each iteration.
The same ICCG tolerance is used for all NR iterations and is scaled using the original matrix right hand side vector.
The ICCG tolerance is scaled by the residual independently for each matrix solution.InitialTolerance Double Value of Initial Convergence Tolerance
MinimumTolerance Double Value of Minimum Convergence Tolerance.
IccgTolerance Double Value of Convergence Tolerance
IccgLimit Double Value of Divergence Limit
IccgMaxIteration Flag Value of Maximum Iteration
IccgToleranceScaleIndependent Double The value of convergence tolerance.(Scale independent)
IccgOptimumValue Flag
0 or Off
1 or OnFlag of Convergence Refinement
No Refinement
Optimum RefinementAPhiMethod Flag
0 or Off
1 or Method1
1 or On
2 or Method2Flag of Using A-Phi Method for Calculation
Do Not Use A-Phi Method
Use A-Phi method1
Use A-Phi method1
Use A-Phi method2 (recommended)NonlinearMethod Flag
0 or Newton-Raphson
1 or SuccessiveIterationNonlinear Iterative Calculation Type
Newton-Raphson
Successive IterationConvergenceType Flag
0 or Solution
1 or ResidualVector
2 or MagneticFluxDensityAndCircuit
3 or SolutionExcludingCircuit
4 or ResidualVectorExcludingCircuit
5 or MagneticFluxDensityConvergence determination type
Using Variation of Solution
Using Magnitude of Residual Vector
Using Variation of Magnetic Flux Density and Circuit Variables
Using Variation of Solution (Excluding Circuit Variables)
Using Magnitude of Residual Vector (Excluding Circuit Variables)
Using Variation of Magnetic Flux DensityRelaxationFactor Flag
0 or Off
1 or Type1
2 or Type2
5 or FactorAutoFlag of Relaxation Factor Type
No Relaxation
Relaxation Type 1
The relaxation type2
The relaxation autoNonlinearMaxIteration Flag Number of Nonlinear Iteration
NonlinearTolerance Double Value of Nonlinear Iterative Convergence Tolerance
NonlinearConvergenceB Flag
0 or Off
1 or OnThe maximum amount of change flag of the magnetic flux density
Not set the maximum amount of change in the magnetic flux density
To set the maximum amount of change in the magnetic flux densityNonlinearConvergenceV Flag
0 or Off
1 or OnThe maximum amount of change flag of the voltage
Not set the maximum amount of change in the voltage
To set the maximum amount of change in the voltageNonlinearConvergenceI Flag
0 or Off
1 or OnThe maximum amount of change flag of the current
Not set the maximum amount of change in the current
To set the maximum amount of change in the currentNonlinearConvergenceToleranceB Double The maximum amount of change in the magnetic flux density
NonlinearConvergenceToleranceV Double The maximum amount of change in the voltage
NonlinearConvergenceToleranceI Double The maximum amount of change in the current
NonlinearStrictConvergence Flag
0 or Off
0 or Off
1 or On
1 or OnFlag of Strict Judgment of Nonlinear Iterative Calculation
Normal judgment for convergence of nonlinear
Normal judgment for convergence of nonlinear
Strict judgment for convergence of nonlinear
Strict judgment for convergence of nonlinearNonlinearSpeedup Flag
0 or Off
1 or OnFlag of Using Nonlinear Speeding-up Function
Do not use speeding up nonlinear calculation.
Use speeding up nonlinear calculation.BHCorrection Flag
0 or Off
1 or OnFlag for applying a correction to the BH curve for frequency response analysis.
Do not apply BH curve correction.
Use BH curve correction.MagneticFluxDensity Flag
0 or Off
1 or OnThe flag for output magnetic flux density result
Not output the magnetic flux density.
Output the magnetic flux density.Magnetization Flag
0 or Off
1 or OnThe flag for output magnetization
Not output the magnetization.
Output the magnetization.PermeanceFactor Flag
0 or Off
1 or OnThe flag for output permeance factor
Not output the permeance factor.
Output the permeance factor.Permeability Flag
0 or Off
1 or OnThe flag for output permeability
Not output the permeability.
Output the permeability.DifferentialPermeability Flag
0 or Off
1 or OnThe flag for output differential permeability
Not output the differential permeability.
Output the differential permeability.CurrentDensity Flag
0 or Off
1 or OnThe flag for output current density result
Not output the current density.
Output the current density.LossDensity Flag
0 or Off
1 or OnThe flag for output loss density
Not output the loss density.
Output the loss density.Displacement Flag
0 or Off
1 or OnThe flag for output nodal displacement result
Not output the nodal displacement.
Output the nodal displacement.NodalForce Flag
0 or Off
1 or OnThe flag for output nodal force result
Not output the nodal force.
Output the nodal force.SurfaceForceDensity Flag
0 or Off
1 or OnThe flag for surface force density
Not output the surface force density.
Output the surface force density.LorentzForceDensity Flag
0 or Off
1 or OnThe flag for output Lorentz force density
Not output the Lorentz force density.
Output the lorentz force density.VectorPotential Flag
0 or Off
1 or OnThe flag for output vector potential
Not output the vector potential.
Output the vector potential.Energy Flag
0 or Off
1 or OnThe flag for output energy result
Not output the energy.
Output the energy.Stress Flag
0 or Off
1 or OnThe flag for output stress result
Not output the stress.
Output the stress.DemagnetizationRatio Flag
0 or Off
1 or OnThe flag for output demagnetization ratio (Compared to reference step)
Not output the Demagnetization ratio (Compared to reference step).
Output the Demagnetization ratio (Compared to reference step).DemagnetizationRatioDiffUnDemag Flag
0 or Off
1 or OnThe flag for output demagnetization ratio (Compared to undemagnetized state)
Not output the Demagnetization ratio (Compared to undemagnetized state).
Output the Demagnetization ratio (Compared to undemagnetized state).HysteresisLossDensity Flag
0 or Off
1 or OnThe flag for output hysteresis loss density
Not output the hysteresis loss density
Output the hysteresis loss densityRestartFile Flag
0 or Off
1 or OnThe flag for output restart file
Not output the restart file.
Output the restart file.RestartFileOutputInterval Flag The minimum output interval(minute) for restart file
JCGMonitor Flag
0 or Off
1 or OnThe flag for output ICCG Iteration Count Monitoring file.
Not output the JCG monitor.
Output the JCG monitor.SolverReportFile Flag
0 or Off
1 or OnThe flag for output solver report file
Not output the solver report file.
Output the solver report file.InitialMagnetization Flag
0 or Off
1 or OnThe flag for initial magnetization
Not output the initial magnetization.
Output the initial magnetization.CoerciveForceNormal Flag
0 or Off
1 or OnThe flag to control output of normalized Coercive Force
Do not output the normalized coercive force.
Output the normalized coercive force.MagnetizationRatio Flag
0 or Off
1 or OnThe flag to control output of magnetization ratio
Do not output the magnetization ratio.
Output the magnetization ratio.Temperature Flag
0 or Off
1 or OnThe flag for output temperature
Not output the temperature.
Output the temperature.IronLossDensity Flag
0 or Off
1 or OnThe flag for output iron loss density
Not output the ironloss density.
Output the ironloss density.ElectricField Flag
0 or Off
1 or OnThe flag for output electric field result
Not output the electric field.
Output the electric field.MagneticFluxDensityLamination Flag
0 or Off
1 or OnThe flag to output lamination magnetic flux density
Not output the lamination magnetic flux density
Output the lamination magnetic flux densityMagneticFieldStrengthLamination Flag
0 or Off
1 or OnThe flag to output lamination magnetic field strength
Not output the lamination magnetic field strength
Output the lamination magnetic field strengthEddyCurrentDensityLamination Flag
0 or Off
1 or OnThe flag to output lamination eddy current density
Not output the lamination eddy current density
Output the lamination eddy current densityCurrentLossDensityLamination Flag
0 or Off
1 or OnThe flag to output lamination current loss density
Not output the lamination current loss density
Output the lamination current loss densityHysteresisLossDensityLamination Flag
0 or Off
1 or OnThe flag to output lamination hysteresis loss density
Not output the lamination hysteresis loss density
Output the lamination hysteresis loss densityCriticalCurrentDensity Flag
0 or Off
1 or OnThe flag to output critical current density
Not output the critical current density
Output the critical current densityIronRefMagneticFluxDensity Flag
0 or Off
1 or OnThe flag for output reference magnetic flux density result (Iron)
Not output the reference magnetic flux density (Iron)
Output the reference magnetic flux density (Iron)IronIronLossDensity Flag
0 or Off
1 or OnThe flag for output iron loss density (Iron)
Not output the iron loss density (Iron)
Output the iron loss density (Iron)IronHysteresisLossDensity Flag
0 or Off
1 or OnThe flag for output hysteresis loss density (Iron)
Not output the hysteresis loss density (Iron)
Output the hysteresis loss density (Iron)IronExcessEddyCurrentDensity Flag
0 or Off
1 or OnThe flag for output excess eddy current loss density (Iron)
Not output the excess eddy current loss density (Iron)
Output the excess eddy current loss density (Iron)IronClassicalEddyCurrentDensity Flag
0 or Off
1 or OnThe flag for output classical eddy current loss density (Iron)
Not output the classical eddy current loss density (Iron)
Output the classical eddy current loss density (Iron)IronJouleLossDensity Flag
0 or Off
1 or OnThe flag for output Joule loss density (Iron)
Not output the Joule loss density (Iron)
Output the Joule loss density (Iron)IronStress Flag
0 or Off
1 or OnThe flag for output stress result (Iron)
Not output the stress (Iron)
Output the stress (Iron)IronMagneticFluxDensityLamination Flag
0 or Off
1 or OnThe flag to output lamination magnetic flux density (Iron)
Not output the lamination magnetic flux density (Iron)
Output the lamination magnetic flux density (Iron)IronMagneticFieldStrengthLamination Flag
0 or Off
1 or OnThe flag to output lamination magnetic field strength (Iron)
Not output the lamination magnetic field strength (Iron)
Output the lamination magnetic field strength (Iron)IronEddyCurrentDensityLamination Flag
0 or Off
1 or OnThe flag to output lamination eddy current density (Iron)
Not output the lamination eddy current density (Iron)
Output the lamination eddy current density (Iron)IronCurrentLossDensityLamination Flag
0 or Off
1 or OnThe flag to output lamination current loss density (Iron)
Not output the lamination current loss density (Iron)
Output the lamination current loss density (Iron)IronHysteresisLossDensityLamination Flag
0 or Off
1 or OnThe flag to output lamination hysteresis loss density (Iron)
Not output the lamination hysteresis loss density (Iron)
Output the lamination hysteresis loss density (Iron)OutputTimingMode Flag
0 or Off
1 or FromStep
1 or On
2 or SpecifyIntervalA flag to control timing of output to plot file
Always output from 1st step.
Output from step specified in OutputStartStep.
Output from step specified in OutputStartStep.
Output from step specified Interval.OutputStartStep Flag The first step to use for the output
MinimizeResults Flag
0 or Off
1 or OnFlag to control minimization of output results
Do not minimize output of distributed results for output control
Minimize output of distributed results for output controlOutputIntervalTable Table output control interval table
OutputTimingSameStep Flag
0 or Off
1 or OnFlag to use same step by table and field results
Output another step by table and field results
Output same step by table and field resultsOutputResultsTimingMode Flag
0 or Off
1 or FromStep
1 or On
2 or SpecifyInterval
3 or NoOutputFlag to control step output to result file
Output all steps
Output from step specified by OutputResultStartStep
Output from step specified by OutputResultStartStep
Output from step specified Interval
No OutputOutputResultsStartStep Flag The first step to use for the output
OutputResultsIntervalTable Table output control interval table
Hsusr1 Flag
0 or Off
1 or OnFlag of User Subroutine "hsusr1"
Do Not Use User Subroutine "hsusr1"
Use User Subroutine "hsusr1"Hsusr3 Flag
0 or Off
1 or OnFlag of User Subroutine "hsusr3"
Do Not Use User Subroutine "hsusr3"
Use User Subroutine "hsusr3"Hsusr4 Flag
0 or Off
1 or OnFlag of User Subroutine "hsusr4"
Do Not Use User Subroutine "hsusr4"
Use User Subroutine "hsusr4"Usrfle Flag
0 or Off
1 or OnFlag of User Subroutine "usrfle"
Do Not Use User Subroutine "usrfle"
Use User Subroutine "usrfle"Usrstp Flag
0 or Off
1 or OnFlag of User Subroutine "usrstp"
Do Not Use User Subroutine "usrstp"
Use User Subroutine "usrstp"Usrlos Flag
0 or Off
1 or OnFlag of User Subroutine "usrlos"
Do Not Use User Subroutine "usrlos"
Use User Subroutine "usrlos"Usrhys Flag
0 or Off
1 or OnFlag of User Subroutine "usrhys"
Do Not Use User Subroutine "usrhys"
Use User Subroutine "usrhys"Usrfm2 Flag
0 or Off
1 or OnFlag of User Subroutine "usrfm2"
Do Not Use User Subroutine "usrfm2"
Use User Subroutine "usrfm2"Usrfma Flag
0 or Off
1 or On
2 or usrfm3The flag of user subroutine "usrfma"
Not use user subroutine "usrfma"
Use user subroutine "usrfma"
Use user subroutine "usrfm3"Usrstr Flag
0 or Off
1 or OnThe flag of user subroutine "usrstr"
Not use user subroutine "usrstr"
Use user subroutine "usrstr"UsrArraySize Flag The size of users subroutine point array
UsrsubName String User Subroutine Name
Snapshot Flag
0 or Off
1 or OnThe flag for Snapshot
Not use Snapshot
Use SnapshotRetry Flag Number of retries
Divisions Flag Number of steps divided
Monitor Flag
0 or Off
1 or OnThe flag to output monitoring file during analysis execution
Do not output the monitoring file during analysis execution
Output a monitoring file during analysis executionCsvOutputPath String The output path for the csv files
CsvResultTypes String The list of result types to output the csv files
CsvOutputResponseData Flag CSV file output response value
CsvOutputInductanceData Flag CSV file output efficiency map inductance values
CsvOutputProbe Flag CSV file output probe value
CsvOutputSection Flag CSV file output section graph value
CsvOutputCalculation Flag CSV file output calculation value
CsvOutputObjectiveData Flag CSV file output objective value
CsvComponentType Flag
0 or RealImaginary
1 or AmplitudePhase
2 or RMSFlag of component output type
Output real and imaginary
Output amplitude and phase
Output rmsCsvDivisionType Flag
0 or Off
1 or OnFlag of divide CSV file output by specified number of cases
Do not divide
Divide CSV outputCsvDivisionCase Flag Specified number of cases
OutputControlType Flag
0 or SpecifyOutputResultItems
1 or OutputTableOnly
2 or DeleteResultFilesThe output control type
Specify Result Items to be Output.
Output only table results.
Delete result files.LogOutputLevel Flag
0 or Debug
1 or Information
2 or Warning
3 or ErrorThe log output level
Debug
Information
Warning
Error
- Study Properties(TransformerMagControl)
TransformerMagControl properties
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
FullModelConversion Flag
0 or Off
1 or OnFlag for Conversion to Value in Full Model
The result is not converted as a full model.
The result is converted as a full model.ConversionFactor Double Conversion factor excluding periodic boundary
Coupling Flag
0 or Off
1 or OnFlag for Coupled Analysis
Do not run the Coupled Analysis.
Run the coupled analysis.CoupledRemesh Flag
0 or Off
1 or OnThe flag for coupled remesh region
The region is not coupled remesh.
The air region is coupled remesh.ConversionType Flag
0 or NotUse
1 or Periodic
2 or SeriesParallelThe flag of circuit conversion type
The circuit conversion is not used.
The periodic conversion type
The circuit conversion type for series/parallelCircuitConversionFactor Double The conversion factor of circuit
CircuitConnect Flag
0 or Series
1 or Parallel
2 or AntiParallelThe circuit connect information
The series type
The parallel type
The anti parallel typePowerCalcTolerance Double The power calculation tolerance
PowerCalcInitialCurrent Double The power calculation initial current
PowerCalcMaxIteration Flag The calculation max iteration
Series Double The number of series
Parallel Double The number of parallel
ConnectionMode Flag
0 or ModifiedNodal
1 or ClosedLoopThs circuit analysis method
The modified nodal analysis type
The closed loop current analysis typeUseWindingFactor Flag
0 or Off
1 or OnThe flag of use conversion factors from winding
Set conversion factors manually
Set conversion factors from windingUseForceCorrection Flag
0 or Off
1 or OnThe Force Correction
The force correction is not used.
The force correction is used.SymmetryPlane1 Coordinate The symmetry plane 1 for the force correction
SymmetryPlane2 Coordinate The symmetry plane 2 for the force correction
ApproximateTransientAnalysis Flag
0 or Off
1 or OnThe flag for use steady-state approximate transient analysis
Do not use steady-state approximate transient analysis
Use steady-state approximate transient analysisSpecifySlip Flag
0 or Off
1 or OnThe flag for stationary device or induction motor
Set as stationary device.
User can specify slip as induction motor.SteadyLinear Flag
0 or Nonlinear
1 or LinearThe flag to control non-linear type for pseudo steady state analysis.
Use conventional method of quasi steady state analysis.
Use fast acceleration of quasi-steady state analysis.Slip Double Slip value(s <= 1)
OutputSteadyResultAs1stStep Flag
0 or Off
1 or OnThe flag for output steady result as 1st step
Do not output steady result as 1st step
Output steady result as 1st stepSetPseudoSteadyStateFreq Flag
0 or Off
1 or OnThe flag for setting pseudo-steady state frequency
Do not use frequency for pseudo steady-state
Use frequency for pseudo steady-statePseudoSteadyStateFrequency Double pseudo steady-state frequency
SetUseCorrectBHCurve Flag
0 or Off
1 or OnThe flag for using correct bh curve for pseudo-steady state
Do not use correct bh curve for pseudo steady-state
Use correct bh curve for pseudo steady-stateTimePeriodicEEC Flag
0 or Off
1 or OnThe flag for time periodic explicit error correction
The time periodic explicit error correction is not executed.
The time periodic explicit error correction is executed.TimePeriodicType Flag
1 or AntiPeriodic
2 or PeriodicThe flag of time periodic type
Anti-Periodic
PeriodicReversePeriodic Flag
0 or Off
1 or OnThe flag reverse periodic rotor
The reverse periodic rotor is not used.
The reverse periodic rotor is used.UseRelaxation Flag
0 or Off
1 or OnThe flag use non-linear relaxation
Non-linear relaxation is not used
Use non-linear relaxation.CorrectionType Flag
0 or frequency
1 or stepThe flag for correction type
The correction type is frequency.
The correction type is step.CorrectionFrequency Double Frequency of correction
CorrectionInterval Flag Interval of correction step
MaxCorrections Flag Max number of correction process
FailureConvergenceError Flag
0 or Off
1 or OnThe flag to handle the failure of convergence as an error
Warning.
Error(Solver will terminate).CalculateDisplacementCurrentInAir Flag
0 or Off
1 or OnThe flag to control calculation of displacement currents in air regions
Do not calculate displacement currents in air regions.
Calculate displacement currents in air regions.ShortenCorrectionInterval Flag
0 or Off
1 or OnThe flag for shortening interval check
Do usual interval check.
Shorten interval check.AllStepsTransientCalculation Flag
0 or Off
1 or OnThe flag for calculate and output all steps of transient calculation
Do not calculate and output all steps of transient calculation.
Calculate and output all steps of transient calculation.UseGPU Flag
0 or Off
1 or OnThe flag for use GPU
Not use GPU.
Use GPU.RestartType Flag
0 or NotRestart
1 or FromTR
2 or FromFQThe restart type
Do not use restart.
Restart from transient analysis
Restart from frequency analysisRestartSavFile String The sav file for restart
RestartMsvFile String The msv file for restart
RestartSvcFile String The svc file for restart
DirectSolverType Flag
0 or ICCG
1 or DirectThe flag of linear solver type
ICCG
Direct solverIccgAccel Double Value of Acceleration Coefficient
AutoAccel Flag
0 or Off
1 or OnFlag to Set Acceleration Coefficient Automatically
The acceleration coefficient is set in manual.
The acceleration coefficient is automatically set.ICCGToleranceType Flag
1 or Automatic
2 or Constant
4 or ScaleIndependentFlag of ICCG Calculation Type
The ICCG tolerance is scaled using the original matrix right hand side vector. The tolerance is then adjusted automatically at each iteration.
The same ICCG tolerance is used for all NR iterations and is scaled using the original matrix right hand side vector.
The ICCG tolerance is scaled by the residual independently for each matrix solution.InitialTolerance Double Value of Initial Convergence Tolerance
MinimumTolerance Double Value of Minimum Convergence Tolerance.
IccgTolerance Double Value of Convergence Tolerance
IccgLimit Double Value of Divergence Limit
IccgMaxIteration Flag Value of Maximum Iteration
IccgToleranceScaleIndependent Double The value of convergence tolerance.(Scale independent)
IccgOptimumValue Flag
0 or Off
1 or OnFlag of Convergence Refinement
No Refinement
Optimum RefinementAPhiMethod Flag
0 or Off
1 or Method1
1 or On
2 or Method2Flag of Using A-Phi Method for Calculation
Do Not Use A-Phi Method
Use A-Phi method1
Use A-Phi method1
Use A-Phi method2 (recommended)NonlinearMethod Flag
0 or Newton-Raphson
1 or SuccessiveIterationNonlinear Iterative Calculation Type
Newton-Raphson
Successive IterationConvergenceType Flag
0 or Solution
1 or ResidualVector
2 or MagneticFluxDensityAndCircuit
3 or SolutionExcludingCircuit
4 or ResidualVectorExcludingCircuit
5 or MagneticFluxDensityConvergence determination type
Using Variation of Solution
Using Magnitude of Residual Vector
Using Variation of Magnetic Flux Density and Circuit Variables
Using Variation of Solution (Excluding Circuit Variables)
Using Magnitude of Residual Vector (Excluding Circuit Variables)
Using Variation of Magnetic Flux DensityRelaxationFactor Flag
0 or Off
1 or Type1
2 or Type2
5 or FactorAutoFlag of Relaxation Factor Type
No Relaxation
Relaxation Type 1
The relaxation type2
The relaxation autoNonlinearMaxIteration Flag Number of Nonlinear Iteration
NonlinearTolerance Double Value of Nonlinear Iterative Convergence Tolerance
NonlinearConvergenceB Flag
0 or Off
1 or OnThe maximum amount of change flag of the magnetic flux density
Not set the maximum amount of change in the magnetic flux density
To set the maximum amount of change in the magnetic flux densityNonlinearConvergenceV Flag
0 or Off
1 or OnThe maximum amount of change flag of the voltage
Not set the maximum amount of change in the voltage
To set the maximum amount of change in the voltageNonlinearConvergenceI Flag
0 or Off
1 or OnThe maximum amount of change flag of the current
Not set the maximum amount of change in the current
To set the maximum amount of change in the currentNonlinearConvergenceToleranceB Double The maximum amount of change in the magnetic flux density
NonlinearConvergenceToleranceV Double The maximum amount of change in the voltage
NonlinearConvergenceToleranceI Double The maximum amount of change in the current
NonlinearStrictConvergence Flag
0 or Off
0 or Off
1 or On
1 or OnFlag of Strict Judgment of Nonlinear Iterative Calculation
Normal judgment for convergence of nonlinear
Normal judgment for convergence of nonlinear
Strict judgment for convergence of nonlinear
Strict judgment for convergence of nonlinearNonlinearSpeedup Flag
0 or Off
1 or OnFlag of Using Nonlinear Speeding-up Function
Do not use speeding up nonlinear calculation.
Use speeding up nonlinear calculation.BHCorrection Flag
0 or Off
1 or OnFlag for applying a correction to the BH curve for frequency response analysis.
Do not apply BH curve correction.
Use BH curve correction.MagneticFluxDensity Flag
0 or Off
1 or OnThe flag for output magnetic flux density result
Not output the magnetic flux density.
Output the magnetic flux density.Magnetization Flag
0 or Off
1 or OnThe flag for output magnetization
Not output the magnetization.
Output the magnetization.PermeanceFactor Flag
0 or Off
1 or OnThe flag for output permeance factor
Not output the permeance factor.
Output the permeance factor.Permeability Flag
0 or Off
1 or OnThe flag for output permeability
Not output the permeability.
Output the permeability.DifferentialPermeability Flag
0 or Off
1 or OnThe flag for output differential permeability
Not output the differential permeability.
Output the differential permeability.CurrentDensity Flag
0 or Off
1 or OnThe flag for output current density result
Not output the current density.
Output the current density.LossDensity Flag
0 or Off
1 or OnThe flag for output loss density
Not output the loss density.
Output the loss density.Displacement Flag
0 or Off
1 or OnThe flag for output nodal displacement result
Not output the nodal displacement.
Output the nodal displacement.NodalForce Flag
0 or Off
1 or OnThe flag for output nodal force result
Not output the nodal force.
Output the nodal force.SurfaceForceDensity Flag
0 or Off
1 or OnThe flag for surface force density
Not output the surface force density.
Output the surface force density.LorentzForceDensity Flag
0 or Off
1 or OnThe flag for output Lorentz force density
Not output the Lorentz force density.
Output the lorentz force density.VectorPotential Flag
0 or Off
1 or OnThe flag for output vector potential
Not output the vector potential.
Output the vector potential.Energy Flag
0 or Off
1 or OnThe flag for output energy result
Not output the energy.
Output the energy.Stress Flag
0 or Off
1 or OnThe flag for output stress result
Not output the stress.
Output the stress.DemagnetizationRatio Flag
0 or Off
1 or OnThe flag for output demagnetization ratio (Compared to reference step)
Not output the Demagnetization ratio (Compared to reference step).
Output the Demagnetization ratio (Compared to reference step).DemagnetizationRatioDiffUnDemag Flag
0 or Off
1 or OnThe flag for output demagnetization ratio (Compared to undemagnetized state)
Not output the Demagnetization ratio (Compared to undemagnetized state).
Output the Demagnetization ratio (Compared to undemagnetized state).HysteresisLossDensity Flag
0 or Off
1 or OnThe flag for output hysteresis loss density
Not output the hysteresis loss density
Output the hysteresis loss densityRestartFile Flag
0 or Off
1 or OnThe flag for output restart file
Not output the restart file.
Output the restart file.RestartFileOutputInterval Flag The minimum output interval(minute) for restart file
JCGMonitor Flag
0 or Off
1 or OnThe flag for output ICCG Iteration Count Monitoring file.
Not output the JCG monitor.
Output the JCG monitor.SolverReportFile Flag
0 or Off
1 or OnThe flag for output solver report file
Not output the solver report file.
Output the solver report file.InitialMagnetization Flag
0 or Off
1 or OnThe flag for initial magnetization
Not output the initial magnetization.
Output the initial magnetization.CoerciveForceNormal Flag
0 or Off
1 or OnThe flag to control output of normalized Coercive Force
Do not output the normalized coercive force.
Output the normalized coercive force.MagnetizationRatio Flag
0 or Off
1 or OnThe flag to control output of magnetization ratio
Do not output the magnetization ratio.
Output the magnetization ratio.Temperature Flag
0 or Off
1 or OnThe flag for output temperature
Not output the temperature.
Output the temperature.IronLossDensity Flag
0 or Off
1 or OnThe flag for output iron loss density
Not output the ironloss density.
Output the ironloss density.ElectricField Flag
0 or Off
1 or OnThe flag for output electric field result
Not output the electric field.
Output the electric field.MagneticFluxDensityLamination Flag
0 or Off
1 or OnThe flag to output lamination magnetic flux density
Not output the lamination magnetic flux density
Output the lamination magnetic flux densityMagneticFieldStrengthLamination Flag
0 or Off
1 or OnThe flag to output lamination magnetic field strength
Not output the lamination magnetic field strength
Output the lamination magnetic field strengthEddyCurrentDensityLamination Flag
0 or Off
1 or OnThe flag to output lamination eddy current density
Not output the lamination eddy current density
Output the lamination eddy current densityCurrentLossDensityLamination Flag
0 or Off
1 or OnThe flag to output lamination current loss density
Not output the lamination current loss density
Output the lamination current loss densityHysteresisLossDensityLamination Flag
0 or Off
1 or OnThe flag to output lamination hysteresis loss density
Not output the lamination hysteresis loss density
Output the lamination hysteresis loss densityCriticalCurrentDensity Flag
0 or Off
1 or OnThe flag to output critical current density
Not output the critical current density
Output the critical current densityIronRefMagneticFluxDensity Flag
0 or Off
1 or OnThe flag for output reference magnetic flux density result (Iron)
Not output the reference magnetic flux density (Iron)
Output the reference magnetic flux density (Iron)IronIronLossDensity Flag
0 or Off
1 or OnThe flag for output iron loss density (Iron)
Not output the iron loss density (Iron)
Output the iron loss density (Iron)IronHysteresisLossDensity Flag
0 or Off
1 or OnThe flag for output hysteresis loss density (Iron)
Not output the hysteresis loss density (Iron)
Output the hysteresis loss density (Iron)IronExcessEddyCurrentDensity Flag
0 or Off
1 or OnThe flag for output excess eddy current loss density (Iron)
Not output the excess eddy current loss density (Iron)
Output the excess eddy current loss density (Iron)IronClassicalEddyCurrentDensity Flag
0 or Off
1 or OnThe flag for output classical eddy current loss density (Iron)
Not output the classical eddy current loss density (Iron)
Output the classical eddy current loss density (Iron)IronJouleLossDensity Flag
0 or Off
1 or OnThe flag for output Joule loss density (Iron)
Not output the Joule loss density (Iron)
Output the Joule loss density (Iron)IronStress Flag
0 or Off
1 or OnThe flag for output stress result (Iron)
Not output the stress (Iron)
Output the stress (Iron)IronMagneticFluxDensityLamination Flag
0 or Off
1 or OnThe flag to output lamination magnetic flux density (Iron)
Not output the lamination magnetic flux density (Iron)
Output the lamination magnetic flux density (Iron)IronMagneticFieldStrengthLamination Flag
0 or Off
1 or OnThe flag to output lamination magnetic field strength (Iron)
Not output the lamination magnetic field strength (Iron)
Output the lamination magnetic field strength (Iron)IronEddyCurrentDensityLamination Flag
0 or Off
1 or OnThe flag to output lamination eddy current density (Iron)
Not output the lamination eddy current density (Iron)
Output the lamination eddy current density (Iron)IronCurrentLossDensityLamination Flag
0 or Off
1 or OnThe flag to output lamination current loss density (Iron)
Not output the lamination current loss density (Iron)
Output the lamination current loss density (Iron)IronHysteresisLossDensityLamination Flag
0 or Off
1 or OnThe flag to output lamination hysteresis loss density (Iron)
Not output the lamination hysteresis loss density (Iron)
Output the lamination hysteresis loss density (Iron)OutputTimingMode Flag
0 or Off
1 or FromStep
1 or On
2 or SpecifyIntervalA flag to control timing of output to plot file
Always output from 1st step.
Output from step specified in OutputStartStep.
Output from step specified in OutputStartStep.
Output from step specified Interval.OutputStartStep Flag The first step to use for the output
MinimizeResults Flag
0 or Off
1 or OnFlag to control minimization of output results
Do not minimize output of distributed results for output control
Minimize output of distributed results for output controlOutputIntervalTable Table output control interval table
OutputTimingSameStep Flag
0 or Off
1 or OnFlag to use same step by table and field results
Output another step by table and field results
Output same step by table and field resultsOutputResultsTimingMode Flag
0 or Off
1 or FromStep
1 or On
2 or SpecifyInterval
3 or NoOutputFlag to control step output to result file
Output all steps
Output from step specified by OutputResultStartStep
Output from step specified by OutputResultStartStep
Output from step specified Interval
No OutputOutputResultsStartStep Flag The first step to use for the output
OutputResultsIntervalTable Table output control interval table
Hsusr1 Flag
0 or Off
1 or OnFlag of User Subroutine "hsusr1"
Do Not Use User Subroutine "hsusr1"
Use User Subroutine "hsusr1"Hsusr3 Flag
0 or Off
1 or OnFlag of User Subroutine "hsusr3"
Do Not Use User Subroutine "hsusr3"
Use User Subroutine "hsusr3"Hsusr4 Flag
0 or Off
1 or OnFlag of User Subroutine "hsusr4"
Do Not Use User Subroutine "hsusr4"
Use User Subroutine "hsusr4"Usrfle Flag
0 or Off
1 or OnFlag of User Subroutine "usrfle"
Do Not Use User Subroutine "usrfle"
Use User Subroutine "usrfle"Usrstp Flag
0 or Off
1 or OnFlag of User Subroutine "usrstp"
Do Not Use User Subroutine "usrstp"
Use User Subroutine "usrstp"Usrlos Flag
0 or Off
1 or OnFlag of User Subroutine "usrlos"
Do Not Use User Subroutine "usrlos"
Use User Subroutine "usrlos"Usrhys Flag
0 or Off
1 or OnFlag of User Subroutine "usrhys"
Do Not Use User Subroutine "usrhys"
Use User Subroutine "usrhys"Usrfm2 Flag
0 or Off
1 or OnFlag of User Subroutine "usrfm2"
Do Not Use User Subroutine "usrfm2"
Use User Subroutine "usrfm2"Usrfma Flag
0 or Off
1 or On
2 or usrfm3The flag of user subroutine "usrfma"
Not use user subroutine "usrfma"
Use user subroutine "usrfma"
Use user subroutine "usrfm3"Usrstr Flag
0 or Off
1 or OnThe flag of user subroutine "usrstr"
Not use user subroutine "usrstr"
Use user subroutine "usrstr"UsrArraySize Flag The size of users subroutine point array
UsrsubName String User Subroutine Name
Snapshot Flag
0 or Off
1 or OnThe flag for Snapshot
Not use Snapshot
Use SnapshotRetry Flag Number of retries
Divisions Flag Number of steps divided
Monitor Flag
0 or Off
1 or OnThe flag to output monitoring file during analysis execution
Do not output the monitoring file during analysis execution
Output a monitoring file during analysis executionCsvOutputPath String The output path for the csv files
CsvResultTypes String The list of result types to output the csv files
CsvOutputResponseData Flag CSV file output response value
CsvOutputInductanceData Flag CSV file output efficiency map inductance values
CsvOutputProbe Flag CSV file output probe value
CsvOutputSection Flag CSV file output section graph value
CsvOutputCalculation Flag CSV file output calculation value
CsvOutputObjectiveData Flag CSV file output objective value
CsvComponentType Flag
0 or RealImaginary
1 or AmplitudePhase
2 or RMSFlag of component output type
Output real and imaginary
Output amplitude and phase
Output rmsCsvDivisionType Flag
0 or Off
1 or OnFlag of divide CSV file output by specified number of cases
Do not divide
Divide CSV outputCsvDivisionCase Flag Specified number of cases
OutputControlType Flag
0 or SpecifyOutputResultItems
2 or DeleteResultFilesThe output control type
Specify Result Items to be Output.
Delete result files.LogOutputLevel Flag
0 or Debug
1 or Information
2 or Warning
3 or ErrorThe log output level
Debug
Information
Warning
Error
- Transformer Controll(TransformerControl)
TransformerControl properties
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
FlgMode3dSt Flag
0 or Off
1 or OnFlag run as 3D ST mode
3D ST mode is off.
3D ST mode is on.AnalysisType Flag
0 or Stack
1 or CylindricalAnalysis type
Analysis type is stack.
Analysis type is cylindrical.FlgUse3dCorrection Flag
0 or Off
1 or OnFlag use 3D correction
3D correction does not be used.
3D correction is used.FlgUseCoreThicknessCorrection Flag
0 or Off
1 or OnUse correction of model thickness
Core thickness correction is off.
Core thickness correction is on.CoreThickness Double Model Thickness
FlgUseFqAnalysis Flag
0 or Off
1 or OnFlag use FQ analysis
FQ analysis does not be used.
FQ Analysis is used.
- Common(Common)
Common properties
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
UseMultiCPU Flag
0 or NonParallel
0 or Off
1 or SMP
1 or On
2 or MPP
2 or DMPFlag for the use of multi cpu
Do not use multi cpu
Do not use multi cpu
Use SMP
Use SMP
Use MPP
Use DMPMultiCPU Flag Degree of parallelism for SMP
MppCPU Flag MPP process parallelism
MppThread Flag MPP thread parallelism
IronLossMode Flag
0 or Off
1 or OnThe mode of calculation of iron loss conditions
Iron loss is calculated after magnetic field analysis has finished
Iron loss and magnetic field analysis are calculated concurrentlyParallelComputing Flag
0 or Off
1 or OnThe flag of use parallel computing for iron loss conditions
Not use parallel computing for loss conditions
Use parallel computing for loss conditions
- Step(TransientStep)
-
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
Step Flag The number of analysis steps
TimeStep Double The value of time step
StepType Flag
0 or Simple
1 or Uniform
2 or Time
3 or Section
4 or Motion
5 or Dll
6 or DualSelectionThe step type: simple = 0, uniform = 1, time = 2
The interval step
The steps has uniform intervals
The steps is defined by time point array.
The steps is defined by section table.
The steps is defined by the motion.
The steps are defined by the external program.
The steps has two regular intervals.StepDivision Flag The division of steps
EndPoint Double The value of end point
Nonlinear Table The nonlinear vs time point array
MaximumTime Double Value of Maximum Progress
Angle Double The value of movement angle
Distance Double Value of Movement Distance
Division Table Time vs Division Table
FirstEndTime Double The end time of the first period
FirstDivision Flag The number of divisions of the first period
SecondEndTime Double The end time of the second period
SecondDivision Flag The number of divisions of the second period
StopOnSteadyState Flag
0 or Off
1 or OnStop the analysis when steady state is reached.
Do not stop
Stop analysis on steady state
- Frequency Step(FrequencyStep)
-
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
Step Flag The number of analysis steps
StepType Flag
0 or Simple
1 or Uniform
2 or Frequency
3 or Section
4 or TimeThe step type: simple = 0 , uniform = 1 , frequency = 2 , section = 3 , time = 4
Interval Step
The steps has uniform intervals
The steps is defined by frequency point array.
The steps is defined by section point array.
The steps is defined by time vs frequency point array.FrequencyStep Double The value of frequency step
Initialfrequency Double The initial frequency
StartPoint Double The value of start point
EndPoint Double The value of end point
StepDivision Flag The division of steps
Nonlinear Table The nonlinear vs frequency point array
Division Table The frequency vs division point array
TimeVsFrequency Table The frequency vs time point array
- Study Properties(ControlCircuit)
ControlCircuit properties
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
FullModelConversion Flag
0 or Off
1 or OnFlag for Conversion to Value in Full Model
The result is not converted as a full model.
The result is converted as a full model.ConversionFactor Double Conversion factor excluding periodic boundary
ModelThickness Double Thickness of the Model
ManualCoilLength Flag
0 or Off
1 or OnFlag of Independent Length of the Coil from Thickness of the Model
The length of FEM coil is independent from the thickness of the model.
The length of FEM coil is equal to the thickness of the model.CoilLength Double Length of the FEM Coil
Coupling Flag
0 or Off
1 or OnFlag for Coupled Analysis
Do not run the Coupled Analysis.
Run the coupled analysis.CoupledRemesh Flag
0 or Off
1 or OnThe flag for coupled remesh region
The region is not coupled remesh.
The air region is coupled remesh.ConversionType Flag
0 or NotUse
2 or SeriesParallelThe flag of circuit conversion type
The circuit conversion is not used.
The circuit conversion type for series/parallelCircuitConversionFactor Double The conversion factor of circuit
CircuitConnect Flag
0 or Series
1 or Parallel
2 or AntiParallelThe circuit connect information
The series type
The parallel type
The anti parallel typePowerCalcTolerance Double The power calculation tolerance
PowerCalcInitialCurrent Double The power calculation initial current
PowerCalcMaxIteration Flag The calculation max iteration
Series Double The number of series
Parallel Double The number of parallel
ConnectionMode Flag
0 or ModifiedNodal
1 or ClosedLoopThs circuit analysis method
The modified nodal analysis type
The closed loop current analysis typeUseWindingFactor Flag
0 or Off
1 or OnThe flag of use conversion factors from winding
Set conversion factors manually
Set conversion factors from windingUseForceCorrection Flag
0 or Off
1 or OnThe Force Correction
The force correction is not used.
The force correction is used.SymmetryPlane1 Coordinate The symmetry plane 1 for the force correction
CalculationMethod Flag
0 or Direct
2 or IterativeFlag of Calculation Method Type
Use FEM+BEM calculation method.
Use FEM calculation method.ApproximateTransientAnalysis Flag
0 or Off
1 or OnThe flag for use steady-state approximate transient analysis
Do not use steady-state approximate transient analysis
Use steady-state approximate transient analysisSpecifySlip Flag
0 or Off
1 or OnThe flag for stationary device or induction motor
Set as stationary device.
User can specify slip as induction motor.SteadyLinear Flag
0 or Nonlinear
1 or LinearThe flag to control non-linear type for pseudo steady state analysis.
Use conventional method of quasi steady state analysis.
Use fast acceleration of quasi-steady state analysis.Slip Double Slip value(s <= 1)
OutputSteadyResultAs1stStep Flag
0 or Off
1 or OnThe flag for output steady result as 1st step
Do not output steady result as 1st step
Output steady result as 1st stepSetPseudoSteadyStateFreq Flag
0 or Off
1 or OnThe flag for setting pseudo-steady state frequency
Do not use frequency for pseudo steady-state
Use frequency for pseudo steady-statePseudoSteadyStateFrequency Double pseudo steady-state frequency
SetUseCorrectBHCurve Flag
0 or Off
1 or OnThe flag for using correct bh curve for pseudo-steady state
Do not use correct bh curve for pseudo steady-state
Use correct bh curve for pseudo steady-stateTimePeriodicEEC Flag
0 or Off
1 or OnThe flag for time periodic explicit error correction
The time periodic explicit error correction is not executed.
The time periodic explicit error correction is executed.TimePeriodicType Flag
1 or AntiPeriodic
2 or PeriodicThe flag of time periodic type
Anti-Periodic
PeriodicReversePeriodic Flag
0 or Off
1 or OnThe flag reverse periodic rotor
The reverse periodic rotor is not used.
The reverse periodic rotor is used.UseRelaxation Flag
0 or Off
1 or OnThe flag use non-linear relaxation
Non-linear relaxation is not used
Use non-linear relaxation.CorrectionType Flag
0 or frequency
1 or stepThe flag for correction type
The correction type is frequency.
The correction type is step.CorrectionFrequency Double Frequency of correction
CorrectionInterval Flag Interval of correction step
MaxCorrections Flag Max number of correction process
FailureConvergenceError Flag
0 or Off
1 or OnThe flag to handle the failure of convergence as an error
Warning.
Error(Solver will terminate).ShortenCorrectionInterval Flag
0 or Off
1 or OnThe flag for shortening interval check
Do usual interval check.
Shorten interval check.AllStepsTransientCalculation Flag
0 or Off
1 or OnThe flag for calculate and output all steps of transient calculation
Do not calculate and output all steps of transient calculation.
Calculate and output all steps of transient calculation.UseGPU Flag
0 or Off
1 or OnThe flag for use GPU
Not use GPU.
Use GPU.RestartType Flag
0 or NotRestart
1 or FromTRThe restart type
Do not use restart.
RestartRestartSavFile String The sav file for restart
RestartMsvFile String The msv file for restart
RestartSvcFile String The svc file for restart
DirectSolverType Flag
0 or ICCG
1 or Direct
2 or AutoThe flag of linear solver type
ICCG
Direct solver
AutoIccgAccel Double Value of Acceleration Coefficient
AutoAccel Flag
0 or Off
1 or OnFlag to Set Acceleration Coefficient Automatically
The acceleration coefficient is set in manual.
The acceleration coefficient is automatically set.ICCGToleranceType Flag
1 or Automatic
2 or Constant
4 or ScaleIndependentFlag of ICCG Calculation Type
The ICCG tolerance is scaled using the original matrix right hand side vector. The tolerance is then adjusted automatically at each iteration.
The same ICCG tolerance is used for all NR iterations and is scaled using the original matrix right hand side vector.
The ICCG tolerance is scaled by the residual independently for each matrix solution.InitialTolerance Double Value of Initial Convergence Tolerance
MinimumTolerance Double Value of Minimum Convergence Tolerance.
IccgTolerance Double Value of Convergence Tolerance
IccgLimit Double Value of Divergence Limit
IccgMaxIteration Flag Value of Maximum Iteration
IccgToleranceScaleIndependent Double The value of convergence tolerance.(Scale independent)
IccgOptimumValue Flag
0 or Off
1 or OnFlag of Convergence Refinement
No Refinement
Optimum RefinementNonlinearMethod Flag
0 or Newton-Raphson
1 or SuccessiveIterationNonlinear Iterative Calculation Type
Newton-Raphson
Successive IterationConvergenceType Flag
0 or Solution
1 or ResidualVector
2 or MagneticFluxDensityAndCircuit
3 or SolutionExcludingCircuit
4 or ResidualVectorExcludingCircuit
5 or MagneticFluxDensityConvergence determination type
Using Variation of Solution
Using Magnitude of Residual Vector
Using Variation of Magnetic Flux Density and Circuit Variables
Using Variation of Solution (Excluding Circuit Variables)
Using Magnitude of Residual Vector (Excluding Circuit Variables)
Using Variation of Magnetic Flux DensityRelaxationFactor Flag
0 or Off
1 or Type1
2 or Type2
5 or FactorAutoFlag of Relaxation Factor Type
No Relaxation
Relaxation Type 1
The relaxation type2
The relaxation autoNonlinearMaxIteration Flag Number of Nonlinear Iteration
NonlinearTolerance Double Value of Nonlinear Iterative Convergence Tolerance
NonlinearConvergenceB Flag
0 or Off
1 or OnThe maximum amount of change flag of the magnetic flux density
Not set the maximum amount of change in the magnetic flux density
To set the maximum amount of change in the magnetic flux densityNonlinearConvergenceV Flag
0 or Off
1 or OnThe maximum amount of change flag of the voltage
Not set the maximum amount of change in the voltage
To set the maximum amount of change in the voltageNonlinearConvergenceI Flag
0 or Off
1 or OnThe maximum amount of change flag of the current
Not set the maximum amount of change in the current
To set the maximum amount of change in the currentNonlinearConvergenceToleranceB Double The maximum amount of change in the magnetic flux density
NonlinearConvergenceToleranceV Double The maximum amount of change in the voltage
NonlinearConvergenceToleranceI Double The maximum amount of change in the current
NonlinearStrictConvergence Flag
0 or Off
0 or Off
1 or On
1 or OnFlag of Strict Judgment of Nonlinear Iterative Calculation
Normal judgment for convergence of nonlinear
Normal judgment for convergence of nonlinear
Strict judgment for convergence of nonlinear
Strict judgment for convergence of nonlinearNonlinearSpeedup Flag
0 or Off
1 or OnFlag of Using Nonlinear Speeding-up Function
Do not use speeding up nonlinear calculation.
Use speeding up nonlinear calculation.BHCorrection Flag
0 or Off
1 or OnFlag for applying a correction to the BH curve for frequency response analysis.
Do not apply BH curve correction.
Use BH curve correction.MagneticFluxDensity Flag
0 or Off
1 or OnThe flag for output magnetic flux density result
Not output the magnetic flux density.
Output the magnetic flux density.Magnetization Flag
0 or Off
1 or OnThe flag for output magnetization
Not output the magnetization.
Output the magnetization.PermeanceFactor Flag
0 or Off
1 or OnThe flag for output permeance factor
Not output the permeance factor.
Output the permeance factor.Permeability Flag
0 or Off
1 or OnThe flag for output permeability
Not output the permeability.
Output the permeability.DifferentialPermeability Flag
0 or Off
1 or OnThe flag for output differential permeability
Not output the differential permeability.
Output the differential permeability.CurrentDensity Flag
0 or Off
1 or OnThe flag for output current density result
Not output the current density.
Output the current density.LossDensity Flag
0 or Off
1 or OnThe flag for output loss density
Not output the loss density.
Output the loss density.Displacement Flag
0 or Off
1 or OnThe flag for output nodal displacement result
Not output the nodal displacement.
Output the nodal displacement.NodalForce Flag
0 or Off
1 or OnThe flag for output nodal force result
Not output the nodal force.
Output the nodal force.SurfaceForceDensity Flag
0 or Off
1 or OnThe flag for surface force density
Not output the surface force density.
Output the surface force density.LorentzForceDensity Flag
0 or Off
1 or OnThe flag for output Lorentz force density
Not output the Lorentz force density.
Output the lorentz force density.VectorPotential Flag
0 or Off
1 or OnThe flag for output vector potential
Not output the vector potential.
Output the vector potential.Energy Flag
0 or Off
1 or OnThe flag for output energy result
Not output the energy.
Output the energy.Stress Flag
0 or Off
1 or OnThe flag for output stress result
Not output the stress.
Output the stress.DemagnetizationRatio Flag
0 or Off
1 or OnThe flag for output demagnetization ratio (Compared to reference step)
Not output the Demagnetization ratio (Compared to reference step).
Output the Demagnetization ratio (Compared to reference step).DemagnetizationRatioDiffUnDemag Flag
0 or Off
1 or OnThe flag for output demagnetization ratio (Compared to undemagnetized state)
Not output the Demagnetization ratio (Compared to undemagnetized state).
Output the Demagnetization ratio (Compared to undemagnetized state).HysteresisLossDensity Flag
0 or Off
1 or OnThe flag for output hysteresis loss density
Not output the hysteresis loss density
Output the hysteresis loss densityRestartFile Flag
0 or Off
1 or OnThe flag for output restart file
Not output the restart file.
Output the restart file.RestartFileOutputInterval Flag The minimum output interval(minute) for restart file
SolverReportFile Flag
0 or Off
1 or OnThe flag for output solver report file
Not output the solver report file.
Output the solver report file.InitialMagnetization Flag
0 or Off
1 or OnThe flag for initial magnetization
Not output the initial magnetization.
Output the initial magnetization.CoerciveForceNormal Flag
0 or Off
1 or OnThe flag to control output of normalized Coercive Force
Do not output the normalized coercive force.
Output the normalized coercive force.MagnetizationRatio Flag
0 or Off
1 or OnThe flag to control output of magnetization ratio
Do not output the magnetization ratio.
Output the magnetization ratio.Temperature Flag
0 or Off
1 or OnThe flag for output temperature
Not output the temperature.
Output the temperature.IronLossDensity Flag
0 or Off
1 or OnThe flag for output iron loss density
Not output the ironloss density.
Output the ironloss density.ElectricField Flag
0 or Off
1 or OnThe flag for output electric field result
Not output the electric field.
Output the electric field.MagneticFluxDensityLamination Flag
0 or Off
1 or OnThe flag to output lamination magnetic flux density
Not output the lamination magnetic flux density
Output the lamination magnetic flux densityMagneticFieldStrengthLamination Flag
0 or Off
1 or OnThe flag to output lamination magnetic field strength
Not output the lamination magnetic field strength
Output the lamination magnetic field strengthEddyCurrentDensityLamination Flag
0 or Off
1 or OnThe flag to output lamination eddy current density
Not output the lamination eddy current density
Output the lamination eddy current densityCurrentLossDensityLamination Flag
0 or Off
1 or OnThe flag to output lamination current loss density
Not output the lamination current loss density
Output the lamination current loss densityHysteresisLossDensityLamination Flag
0 or Off
1 or OnThe flag to output lamination hysteresis loss density
Not output the lamination hysteresis loss density
Output the lamination hysteresis loss densityCriticalCurrentDensity Flag
0 or Off
1 or OnThe flag to output critical current density
Not output the critical current density
Output the critical current densityIronRefMagneticFluxDensity Flag
0 or Off
1 or OnThe flag for output reference magnetic flux density result (Iron)
Not output the reference magnetic flux density (Iron)
Output the reference magnetic flux density (Iron)IronIronLossDensity Flag
0 or Off
1 or OnThe flag for output iron loss density (Iron)
Not output the iron loss density (Iron)
Output the iron loss density (Iron)IronHysteresisLossDensity Flag
0 or Off
1 or OnThe flag for output hysteresis loss density (Iron)
Not output the hysteresis loss density (Iron)
Output the hysteresis loss density (Iron)IronExcessEddyCurrentDensity Flag
0 or Off
1 or OnThe flag for output excess eddy current loss density (Iron)
Not output the excess eddy current loss density (Iron)
Output the excess eddy current loss density (Iron)IronClassicalEddyCurrentDensity Flag
0 or Off
1 or OnThe flag for output classical eddy current loss density (Iron)
Not output the classical eddy current loss density (Iron)
Output the classical eddy current loss density (Iron)IronJouleLossDensity Flag
0 or Off
1 or OnThe flag for output Joule loss density (Iron)
Not output the Joule loss density (Iron)
Output the Joule loss density (Iron)IronStress Flag
0 or Off
1 or OnThe flag for output stress result (Iron)
Not output the stress (Iron)
Output the stress (Iron)IronMagneticFluxDensityLamination Flag
0 or Off
1 or OnThe flag to output lamination magnetic flux density (Iron)
Not output the lamination magnetic flux density (Iron)
Output the lamination magnetic flux density (Iron)IronMagneticFieldStrengthLamination Flag
0 or Off
1 or OnThe flag to output lamination magnetic field strength (Iron)
Not output the lamination magnetic field strength (Iron)
Output the lamination magnetic field strength (Iron)IronEddyCurrentDensityLamination Flag
0 or Off
1 or OnThe flag to output lamination eddy current density (Iron)
Not output the lamination eddy current density (Iron)
Output the lamination eddy current density (Iron)IronCurrentLossDensityLamination Flag
0 or Off
1 or OnThe flag to output lamination current loss density (Iron)
Not output the lamination current loss density (Iron)
Output the lamination current loss density (Iron)IronHysteresisLossDensityLamination Flag
0 or Off
1 or OnThe flag to output lamination hysteresis loss density (Iron)
Not output the lamination hysteresis loss density (Iron)
Output the lamination hysteresis loss density (Iron)OutputTimingMode Flag
0 or Off
1 or FromStep
1 or On
2 or SpecifyIntervalA flag to control timing of output to plot file
Always output from 1st step.
Output from step specified in OutputStartStep.
Output from step specified in OutputStartStep.
Output from step specified Interval.OutputStartStep Flag The first step to use for the output
MinimizeResults Flag
0 or Off
1 or OnFlag to control minimization of output results
Do not minimize output of distributed results for output control
Minimize output of distributed results for output controlOutputIntervalTable Table output control interval table
OutputTimingSameStep Flag
0 or Off
1 or OnFlag to use same step by table and field results
Output another step by table and field results
Output same step by table and field resultsOutputResultsTimingMode Flag
0 or Off
1 or FromStep
1 or On
2 or SpecifyInterval
3 or NoOutputFlag to control step output to result file
Output all steps
Output from step specified by OutputResultStartStep
Output from step specified by OutputResultStartStep
Output from step specified Interval
No OutputOutputResultsStartStep Flag The first step to use for the output
OutputResultsIntervalTable Table output control interval table
Hsusr1 Flag
0 or Off
1 or OnFlag of User Subroutine "hsusr1"
Do Not Use User Subroutine "hsusr1"
Use User Subroutine "hsusr1"Hsusr3 Flag
0 or Off
1 or OnFlag of User Subroutine "hsusr3"
Do Not Use User Subroutine "hsusr3"
Use User Subroutine "hsusr3"Hsusr4 Flag
0 or Off
1 or OnFlag of User Subroutine "hsusr4"
Do Not Use User Subroutine "hsusr4"
Use User Subroutine "hsusr4"Usrfle Flag
0 or Off
1 or OnFlag of User Subroutine "usrfle"
Do Not Use User Subroutine "usrfle"
Use User Subroutine "usrfle"Usrstp Flag
0 or Off
1 or OnFlag of User Subroutine "usrstp"
Do Not Use User Subroutine "usrstp"
Use User Subroutine "usrstp"Usrlos Flag
0 or Off
1 or OnFlag of User Subroutine "usrlos"
Do Not Use User Subroutine "usrlos"
Use User Subroutine "usrlos"Usrhys Flag
0 or Off
1 or OnFlag of User Subroutine "usrhys"
Do Not Use User Subroutine "usrhys"
Use User Subroutine "usrhys"Usrfm2 Flag
0 or Off
1 or OnFlag of User Subroutine "usrfm2"
Do Not Use User Subroutine "usrfm2"
Use User Subroutine "usrfm2"Usrfma Flag
0 or Off
1 or On
2 or usrfm3The flag of user subroutine "usrfma"
Not use user subroutine "usrfma"
Use user subroutine "usrfma"
Use user subroutine "usrfm3"Usrstr Flag
0 or Off
1 or OnThe flag of user subroutine "usrstr"
Not use user subroutine "usrstr"
Use user subroutine "usrstr"UsrArraySize Flag The size of users subroutine point array
UsrsubName String User Subroutine Name
Snapshot Flag
0 or Off
1 or OnThe flag for Snapshot
Not use Snapshot
Use SnapshotRetry Flag Number of retries
Divisions Flag Number of steps divided
Monitor Flag
0 or Off
1 or OnThe flag to output monitoring file during analysis execution
Do not output the monitoring file during analysis execution
Output a monitoring file during analysis executionCsvOutputPath String The output path for the csv files
CsvResultTypes String The list of result types to output the csv files
CsvOutputResponseData Flag CSV file output response value
CsvOutputInductanceData Flag CSV file output efficiency map inductance values
CsvOutputProbe Flag CSV file output probe value
CsvOutputSection Flag CSV file output section graph value
CsvOutputCalculation Flag CSV file output calculation value
CsvOutputObjectiveData Flag CSV file output objective value
CsvComponentType Flag
0 or RealImaginary
1 or AmplitudePhase
2 or RMSFlag of component output type
Output real and imaginary
Output amplitude and phase
Output rmsCsvDivisionType Flag
0 or Off
1 or OnFlag of divide CSV file output by specified number of cases
Do not divide
Divide CSV outputCsvDivisionCase Flag Specified number of cases
OutputControlType Flag
0 or SpecifyOutputResultItems
2 or DeleteResultFilesThe output control type
Specify Result Items to be Output.
Delete result files.LogOutputLevel Flag
0 or Debug
1 or Information
2 or Warning
3 or ErrorThe log output level
Debug
Information
Warning
Error