This section describes specifying property names of the specified physical amount as arguments when setting the analysis result table.
The property names are used in the ResultTable class and Study class commands.
-
Result Table of Magnetic Field Analysis (Static Analysis)
Component type
(typeName)Description
Force Force
LorentzForce Lorentz Force
Torque Torque
FluxGroup Flux Condition
JouleLoss Joule Loss
CoilCurrent Current of Current Condition
MagneticFlux Magnetic Flux
CoilFlux Magnetic Flux of Current Condition
StoredEnergy Stored Energy
-
Result Table of Magnetic Field Analysis (Transient Response Analysis)
Component type
(typeName)Description
TotalLossPerCond Total Loss Per Cond
VoltageDifference Voltage Difference
ElectricalTemperatureDiffenrence Temperature Difference (Electrical Circuit)
Force Force
ExternalLoadForce External Program Force
LorentzForce Lorentz Force
TerminalVoltage Circuit Voltage
BrushContactAngle Brush Contact Angle
TotalDisplacementAngle Total Displacement Angle
VelocityAngle Velocity Angle
ElectricalTerminalTemperature Terminal Temperature (Electrical Circuit)
Torque Torque
ExternalLoadTorque External Program Torque
TerminalControlSignal Control Signal
FEMCoilInductance FEM Coil Inductance
FEMCoilFlux Coil Flux-Linkage
FluxGroup Flux Condition
ElectricPower Circuit Electric Power
FEMConductorInductance FEM Conductor Inductance
FEMConductorResistance FEM Conductor Resistance
FEMConductorFlux FEM Conductor Flux-Linkage
JouleLoss Joule Loss
TotalIronLoss Iron Loss
HysteresisLoss Hysteresis Loss
CircuitLoss Circuit Loss
TotalDisplacement Total Displacement
LineCurrent Circuit Current
MagneticFlux Magnetic Flux
CoilFlux Magnetic Flux of Current Condition
StoredEnergy Stored Energy
MovingFrameForce Force (Moving Frame)
MovingFrameTorque Torque (Moving Frame)
TotalRotateDisplacementArbitraryMotion Total rotational displacement (arbitrary motion)
TotalTransDisplacementArbitraryMotion Total translational displacement (arbitrary motion)
RotateVelocityArbitraryMotion Rotational velocity (arbitrary motion)
TransVelocityArbitraryMotion Translational velocity (arbitrary motion)
Velocity Velocity
-
Result Table of Magnetic Field Analysis (Frequency Response Analysis)
Component type
(typeName)Description
TotalLossPerCond Total Loss Per Cond
VoltageDifference Voltage Difference
ElectricalTemperatureDiffenrence Temperature Difference (Electrical Circuit)
Force Force
LorentzForce Lorentz Force
TerminalVoltage Circuit Voltage
VelocityAngle Velocity Angle
ElectricalTerminalTemperature Terminal Temperature (Electrical Circuit)
Torque Torque
FEMCoilInductance FEM Coil Inductance
FEMCoilFlux Coil Flux-Linkage
FluxGroup Flux Condition
ActivePower Active Electric Power
FEMConductorInductance FEM Conductor Inductance
FEMConductorResistance FEM Conductor Resistance
FEMConductorFlux FEM Conductor Flux-Linkage
JouleLoss Joule Loss
TotalIronLoss Iron Loss
CircuitLoss Circuit Loss
LineCurrent Circuit Current
MagneticFlux Magnetic Flux
CoilFlux Magnetic Flux of Current Condition
StoredEnergy Stored Energy
Velocity Velocity
-
Properties Specified in the Result Table (Magnetic Field Analysis)
Component type
(typeName)Description
Flux Magnetic Flux
-
Result Table of Iron Loss Analysis
Component type
(typeName)Description
JouleLossRegion_IronLoss Joule Loss (Residual Strain) (Iron loss)
JouleLossRegion_Time Joule Loss (Residual Strain) (Time Dependent)
ClassicalEddyCurrentLossRegion_IronLoss Classical Eddy Current Loss (Residual Strain) (Iron loss)
ClassicalEddyCurrentLossRegion_Time Classical Eddy Current Loss (Residual Strain) (Time Dependent)
IronLossRegion_IronLoss Iron Loss (Residual Strain) (Iron loss)
IronLossRegion_Time Iron Loss (Residual Strain) (Time Dependent)
HysteresisLossRegion_IronLoss Hysteresis Loss (Residual Strain) (Iron loss)
HysteresisLossRegion_Time Hysteresis Loss (Residual Strain) (Time Dependent)
JouleLossLamination_IronLoss Joule Loss(Lamination) (Iron loss)
JouleLossLamination_Time Joule Loss(Lamination) (Time Dependent)
ExcessEddyCurrentLoss_IronLoss Excess Eddy Current Loss (Iron loss)
ExcessEddyCurrentLoss_Time Excess Eddy Current Loss (Time Dependent)
JouleLoss_IronLoss Joule Loss (Iron loss)
JouleLoss_Time Joule Loss (Time Dependent)
ClassicalEddyCurrentLoss_IronLoss Classical Eddy Current Loss (Iron loss)
ClassicalEddyCurrentLoss_Time Classical Eddy Current Loss (Time Dependent)
IronLoss_IronLoss Iron Loss (Iron loss)
IronLoss_Time Iron Loss (Time Dependent)
HysteresisLoss_IronLoss Hysteresis Loss (Iron loss)
HysteresisLoss_Time Hysteresis Loss (Time Dependent)
ExcessEddyCurrentLossXyz_IronLoss Excess Eddy Current Loss (Each Component) (Iron loss)
ExcessEddyCurrentLossXyz_Time Excess Eddy Current Loss (Each Component) (Time Dependent)
JouleLossXyz_IronLoss Joule Loss (Each Component) (Iron loss)
JouleLossXyz_Time Joule Loss (Each Component) (Time Dependent)
ClassicalEddyCurrentLossXyz_IronLoss Classical Eddy Current Loss (Each Component) (Iron loss)
ClassicalEddyCurrentLossXyz_Time Classical Eddy Current Loss (Each Component) (Time Dependent)
IronLossXyz_IronLoss Iron Loss (Each Component) (Iron loss)
IronLossXyz_Time Iron Loss (Each Component) (Time Dependent)
HysteresisLossXyz_IronLoss Hysteresis Loss (Each Component) (Iron loss)
HysteresisLossXyz_Time Hysteresis Loss (Each Component) (Time Dependent)
-
Result Table of Thermal Analysis
Component type
(typeName)Description
EfficiencyMapVd2 Vd2(Efficiency Map)
EfficiencyMapVq2 Vq2(Efficiency Map)
EfficiencyMapOperatingSpeed Operating Speed(Efficiency Map)
EfficiencyMapId Id(Efficiency Map)
AverageTemperaturePerCond Average Temperature Per Cond
EfficiencyMapVd Vd(Efficiency Map)
CircuitFluidResistance Circuit Fluid Resistance
CircuitThermalResistance Circuit Thermal Resistance
ContactThermalResistance Contact Resistance
PressureDifference Flow Pressure Difference
TemperatureDifference Temperature Difference (Thermal Circuit)
EfficiencyMapVoltage Voltage(Efficiency Map)
EfficiencyMapLeadAngle Lead Angle(Efficiency Map)
TotalDisplacementAngle Total Displacement Angle
CircuitFlowTerminalPressure Flow Terminal Pressure
AverageTemperature Average Temperature
TerminalTemperature Terminal Temperature (Thermal Circuit)
CircuitFlowRate Circuit Flow Rate
EfficiencyMapOperatingTorque Operating Torque(Efficiency Map)
TotalSurfaceHeatGeneration Total Surface Heat Generation
TotalHeatGeneration Total Heat Generation
EfficiencyMapIq Iq(Efficiency Map)
EfficiencyMapVq Vq(Efficiency Map)
HeatGenerationACJouleLoss AC Copper Loss(Efficiency Map)
HeatGenerationPWMJouleLoss PWM Eddy Current Loss(Efficiency Map)
HeatGenerationJouleLoss Eddy Current Loss(Efficiency Map)
HeatGenerationMechanicalLoss Mechanical Loss(Efficiency Map)
HeatGenerationTotalLoss Total Loss(Efficiency Map)
HeatGenerationIronLoss Iron Loss(Efficiency Map)
HeatGenerationCopperLoss Copper Loss(Efficiency Map)
HeatGenerationHysteresisLoss Hysteresis Loss(Efficiency Map)
HeatGenerationMagnetEddyCurrentLoss Magnet Eddy Current Loss(Efficiency Map)
HeatGenerationStrayLoss Stray Loss(Efficiency Map)
CircuitHeatTransferCoefficient Circuit Heat Transfer Coefficient
TotalDisplacement Total Displacement
EfficiencyMapFieldCurrent Field Current(Efficiency Map)
EfficiencyMapCurrent Current(Efficiency Map)
HeatFlow Heat Flow
CircuitHeatFlow Circuit Heat Flow
EfficiencyMapEfficiency Efficiency(Efficiency Map)
-
Result Table of Structural Analysis
Component type
(typeName)Description
MaxSoundPressure Maximum Sound Pressure
MaxSoundPressureLevel Maximum Sound Pressure Level
FrequencyForStep Eigenmodes
MaxMisesStress Maximum Mises Stress
-
Result Table of Electric Field Analysis
Component type
(typeName)Description
Force Force
SurfaceCharge Surface Charge
ThermalEmfLoss Thermal Emf Loss
TotalLoss Total Loss
MaxElectricBreakdownFactor Maximum Electric Breakdown Factor
DielectricLoss Dielectric Loss
JouleLoss Joule Loss
LineCurrent Circuit Current
-
Result Table of Thermal Stress Analysis
-
Result Table of Transformer Analysis (Static Analysis)
Component type
(typeName)Description
CoilInductance Winding Inductance
DirectCurrentResistance Direct Current Resistance
Force Force
LorentzForce Lorentz Force
Torque Torque
FluxGroup Flux Condition
JouleLoss Joule Loss
TotalIronLoss Iron Loss
HysteresisLoss Hysteresis Loss
CoilCurrent Current of Current Condition
MagneticFlux Magnetic Flux
CoilFlux Magnetic Flux of Current Condition
TransformerCoilFlux Winding Flux-Linkage
StoredEnergy Stored Energy
-
Result Table of Transformer Analysis (Transient Response Analysis)
Component type
(typeName)Description
TotalLossPerCond Total Loss Per Cond
CoilInductance Winding Inductance
DirectCurrentResistance Direct Current Resistance
VoltageDifference Voltage Difference
Force Force
LorentzForce Lorentz Force
TerminalVoltage Circuit Voltage
Torque Torque
TerminalControlSignal Control Signal
FEMCoilFlux Coil Flux-Linkage
FluxGroup Flux Condition
ElectricPower Circuit Electric Power
JouleLoss Joule Loss
TotalIronLoss Iron Loss
HysteresisLoss Hysteresis Loss
CircuitLoss Circuit Loss
LineCurrent Circuit Current
MagneticFlux Magnetic Flux
CoilFlux Magnetic Flux of Current Condition
TransformerCoilFlux Winding Flux-Linkage
StoredEnergy Stored Energy
-
Result Table of Transformer Analysis (Frequency Response Analysis)
Component type
(typeName)Description
TotalLossPerCond Total Loss Per Cond
CoilInductance Winding Inductance
DirectCurrentResistance Direct Current Resistance
VoltageDifference Voltage Difference
Force Force
LorentzForce Lorentz Force
TerminalVoltage Circuit Voltage
BrushContactAngle Brush Contact Angle
Torque Torque
FEMCoilFlux Coil Flux-Linkage
FluxGroup Flux Condition
JouleLoss Joule Loss
TotalIronLoss Iron Loss
HysteresisLoss Hysteresis Loss
CircuitLoss Circuit Loss
LineCurrent Circuit Current
MagneticFlux Magnetic Flux
CoilFlux Magnetic Flux of Current Condition
TransformerCoilFlux Winding Flux-Linkage
StoredEnergy Stored Energy