- Fixed Temperature(FixedTemperature)
The fixed temperature
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
FixedTemperature Double The fixed temperature
- Foot Mounting Base(FootMountingBase)
The foot mounting base
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
RemoveFromMotor Flag
0 or Not remove
1 or RemoveThe flag to remove base from motor
The base is used.
The base is removed from motor.FootMaterialType Flag
0 or Custom
1 or S45C
2 or SUS304
3 or AluminiumThe type of foot material
Use custom.
Use S45C.
Use SUS304.
Use Aluminium.FootDensity Double The foot density
FootThermalConductivity Double The foot thermal conductivity
FootSpecificHeat Double The foot specific heat
FootWidthMotor Double The foot width (motor)
FootWidthBase Double The foot width (base)
FootLength Double The foot length
FootThicknessMotor Double The foot thickness (motor)
FootThicknessBase Double The foot thickness (base)
BaseMaterialType Flag
0 or Custom
1 or S45C
2 or SUS304
3 or AluminiumThe type of base material
Use custom.
Use S45C.
Use SUS304.
Use Aluminium.BaseDensity Double The base density
BaseThermalConductivity Double The base thermal conductivity
BaseSpecificHeat Double The base specific heat
BaseWidth Double The base width
BaseThickness Double The base thickness
BaseLength Double The base length
BaseTemperature Double The base temperature
HousingFootFitType Flag
0 or Custom
1 or GoodFit
2 or BadFitThe flag for housing foot fit type
Use custom.
Use good fit.
Use bad fit.HousingFootGap Double The housing foot gap
HousingFootThermalConductivity Double The housing foot thermal conductivity
FootBaseFitType Flag
0 or Custom
1 or GoodFit
2 or BadFitThe flag for foot base fit type
Use custom.
Use good fit.
Use bad fit.FootBaseGap Double The foot base gap
FootBaseThermalConductivity Double The foot base thermal conductivity
AmbientTemperature Double The ambient temperature
UseAutoCalculation Flag
0 or Off
1 or OnUse auto calculation
Not using auto calculation
Using auto calculationHousingFootResistanceCorrectionCoefficient Double The correction coefficient of housing foot resistance
FootResistanceCorrectionCoefficient Double The correction coefficient of foot resistance
FootCapacitanceCorrectionCoefficient Double The correction coefficient of foot capacitance
FootBaseResistanceCorrectionCoefficient Double The correction coefficient of foot base resistance
BaseResistanceCorrectionCoefficient Double The correction coefficient of base resistance
BaseCapacitanceCorrectionCoefficient Double The correction coefficient of base capacitance
NaturalConvectionCorrectionCoefficient Double The correction coefficient of natural convection
- Flange Mounting Plate(FlangeMountingPlate)
The flange mounting plate
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
RemoveFromMotor Flag
0 or Not remove
1 or RemoveThe flag to remove plate from motor
The plate is used.
The plate is removed from motor.StatorDiameter Double The stator diameter
HousingThickness Double The housing thickness
FlangeDiameter Double The flange diameter
FlangeExtension Double The flange extension
FlangeDepth Double The flange depth
PlateMaterialType Flag
0 or Custom
1 or S45C
2 or SUS304
3 or AluminiumThe type of plate material
Use custom.
Use S45C.
Use SUS304.
Use Aluminium.PlateDensity Double The plate density
PlateThermalConductivity Double The plate thermal conductivity
PlateSpecificHeat Double The plate specific heat
PlateHeight Double The plate height
PlateWidth Double The plate width
PlateThickness Double The plate thickness
PlateTemperature Double The plate temperature
FlangePlateFitType Flag
0 or Custom
1 or GoodFit
2 or BadFitThe flag for flange plate fit type
Use custom.
Use good fit.
Use bad fit.FlangePlateGap Double The flange plate gap
FlangePlateThermalConductivity Double The flange plate thermal conductivity
AmbientTemperature Double The ambient temperature
UseAutoCalculation Flag
0 or Off
1 or OnUse auto calculation
Not using auto calculation
Using auto calculationFitResistanceCorrectionCoefficient Double The correction coefficient of fit resistance
PlateResistanceCorrectionCoefficient Double The correction coefficient of plate resistance
PlateCpacitanceCorrectionCoefficient Double The correction coefficient of plate capacitance
NaturalConvectionCorrectionCoefficient Double The correction coefficient of natural convection
- Coil End Cooling(CoilEndCooling)
The coil end cooling
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
ThermalResistance Double The thermal resistance (coil end)
HeatCapacity Double The heat capacity (coil end)
CoolingType Flag
0 or Thermal Resistance (Constant)
1 or Natural Convection
2 or Forced Convection
3 or Mixed Convection
4 or Spray
5 or ATF Spray (Top) + ATF Pool
6 or ATF Spray (Sides) + ATF Pool
7 or Thermal Resistance (Constant1~4)
8 or Thermal Resistance (User-Defined)The cooling type
Using a constant thermal resistance
Using natural convection cooling
Using forced convection cooling
Using mixed convection cooling
Using spray cooling
Using ATF spray (Top) and ATF pool cooling
Using ATF spray (Sides) and ATF pool cooling
Using 4 constant thermal resistances
User-Defined thermal resistancesTwoTerminalCoilEndCooling Flag
0 or Off
1 or OnTwo terminal coil end cooling component for ATF Spray and ATF pool
Three terminal coil end cooling component for ATF Spray and ATF pool
Two terminal coil end cooling component for ATF Spray and ATF poolStartAngle Double The start angle
RangeAngle1 Double The range angle 1
RangeAngle2 Double The range angle 2
RangeAngle3 Double The range angle 3
ThermalResistanceCooling1 Double Constant / Constant 1 (Cooling)
ThermalResistanceCooling2 Double Constant 2 (Cooling)
ThermalResistanceCooling3 Double Constant 3 (Cooling)
ThermalResistanceCooling4 Double Constant 4 (Cooling)
ConvectionCoolantType Flag
0 or Air
1 or Water
2 or Oil
3 or ATF Oil
4 or CustomThe flag for convection coolant type
Use air.
Use water.
Use oil.
Use ATF oil.
Use custom.ATFCoolantType Flag
3 or ATFOil
4 or CustomThe flag for ATF coolant type
Use ATF oil.
Use custom.ConvectionThermalArea Double The convection thermal area
CorrectionCoefficient Double The correction coefficient
CoolantTemperature Double The coolant temperature
ForcedConvectionType Flag
0 or Circumferential
1 or AxisDirection
2 or MotorGapThe flag for forced convection type
Use circumferential.
Use axis direction.
Use motor gap (radial).ConvectionInputFlowType Flag
0 or FlowVelocity
2 or ReferenceFlowCircuitThe flag for convection input flow type
Use flow velocity.
Reference flow circuit.ConvectionFlowVelocity Double The convection flow velocity
ConvectionReferenceFlowRateProbe Int The convection referenced flow rate probe id
PreviewConvectionFlowVelocity Double The convection flow velocity (preview)
GapWidth Double The gap width
RotorRadius Double The rotor radius
CharacteristicLengthForced Double The characteristic length (forced)
NaturalConvectionType Flag
0 or HorizontalCylinder
1 or VerticalCylinder
2 or VerticalFlatPlate
3 or HorizontalPlateUpper
4 or HorizontalPlateLowerThe flag for natural convection type
Use horizontal cylinder.
Use vertical cylinder.
Use vertical flat plate.
Use horizontal plate upper.
Use horizontal plate lower.CharacteristicLengthNatural Double The characteristic length (natural)
CorrectionNatural Double The correction coefficient (natural)
MixedDirectionType Flag
0 or AssistingOrTransverse
1 or OpposingThe flag for mixed direction type
Assisting or Transverse.
Opposing.TerminalTemperature Double The terminal temperature (preview)
ConvectionPreviewCoolantTemperature Double The coolant temperature (preview)
SprayType Flag
0 or GeneralSpray
1 or SpecifyNozzlePositionThe flag for spray type
General spray.
Specify nozzle position.NozzlePosition Flag
0 or SprayHousing
1 or SprayEndCap
2 or SprayShaft
3 or SprayHousingAndEndCap
4 or SprayHousingAndShaft
5 or SprayEndCapAndShaft
6 or SprayHousingAndEndCapAndShaftThe flag for nozzle position
Spray from housing.
Spray from end cap.
Spray from shaft.
Spray from housing and end cap.
Spray from housing and shaft.
Spray from end cap and shaft.
Spray from housing and end cap and shaft.CoolantType Flag
1 or Water
2 or Oil
4 or CustomThe flag for coolant type
Use water.
Use oil.
Use custom.SprayATFInputFlowType Flag
0 or FlowVelocity
1 or VolumeFlowRateThe flag for spray or ATF flow type
Use flow velocity.
Use volume flow rate.SprayATFFlowVelocity Double The spray or ATF flow velocity
SprayATFVolumeFlowRate Double The spray or ATF volume flow rate
NozzleDiameter Double The nozzle diameter
SprayATFThermalResistorArea Double The spray or ATF thermal resistor area
SprayATFThermalCorrection Double The spray or ATF thermal correction coefficient
SprayPreviewCoolantTemperature Double The coolant temperature (preview)
CoilEndHeight Double The coil end height
CoilOuterRadius Double The coil outer radius
CoilInnerRadius Double The coil inner radius
CoilEndAreaCorrectionType Flag
0 or UseCorrectionCoefficient
1 or UseCoilEndSurfaceAreaThe flag for spray coil end area correction type
Use correction coefficient.
Use coil end surface area.CoilEndAreaCorrectionCoefficient Double The spray coil end area correction coefficient
CoilEndSurfaceArea Double The coil end surface area
SprayHousingInputFlowType Flag
0 or FlowVelocity
1 or VolumeFlowRateThe flag for spray or ATF flow type
Use flow velocity.
Use volume flow rate.SprayHousingFlowVelocity Double The spray or ATF flow velocity
SprayHousingVolumeFlowRate Double The spray or ATF volume flow rate
SprayHousingNozzleDiameter Double The nozzle diameter
SprayHousingNozzleNumber Flag The number of nozzles
SprayHousingFirstNozzleAngle Double The first nozzle angle
SprayHousingSprayAngle Double The spray angle
SprayHousingHousingInnerRadius Double The housing inner radius
SprayHousingThermalCorrection Double The spray or ATF thermal correction coefficient
SprayEndCapInputFlowType Flag
0 or FlowVelocity
1 or VolumeFlowRateThe flag for spray or ATF flow type
Use flow velocity.
Use volume flow rate.SprayEndCapFlowVelocity Double The spray or ATF flow velocity
SprayEndCapVolumeFlowRate Double The spray or ATF volume flow rate
SprayEndCapNozzleDiameter Double The nozzle diameter
SprayEndCapNozzleNumber Flag The number of nozzles
SprayEndCapFirstNozzleAngle Double The first nozzle angle
SprayEndCapSprayAngle Double The spray angle
SprayEndCapEndCapDistance Double The end cap distance
SprayEndCapThermalCorrection Double The spray or ATF thermal correction coefficient
SprayShaftInputFlowType Flag
0 or FlowVelocity
1 or VolumeFlowRateThe flag for spray or ATF flow type
Use flow velocity.
Use volume flow rate.SprayShaftFlowVelocity Double The spray or ATF flow velocity
SprayShaftVolumeFlowRate Double The spray or ATF volume flow rate
SprayShaftNozzleDiameter Double The nozzle diameter
SprayShaftNozzleNumber Flag The number of nozzles
SprayShaftSprayAngle Double The spray angle
SprayShaftShaftOuterRadius Double The shaft outer radius
SprayShaftThermalCorrection Double The spray or ATF thermal correction coefficient
CoolingMaterialTable Table The cooling material table
CoolantTemperatureType Flag
0 or Constant
1 or TerminalAverageValueThe flag for coolant temperature type
Use constant.
Refer to Terminal Average Value.CoolantSourceTemperature Double The cooling source temperature
MonitorCoilEndTemp Flag
0 or Off
1 or OnMonitor coil end temperature
Do not monitor coil end temperature
Monitor coil end temperatureUseVariableCoolantTemperature Flag
0 or Off
1 or OnUse variable coolant temperature
Do not use vaiable coolant temperature
Use variable coolant temperatureThermalUserDefinedScript String The python script for thermal resistance
RotationSpeedType Flag
0 or Constant
1 or PointArray
2 or DriveCycleReferenceThe flag for rotation speed type
The constant type.
The point array type.
Reference ConditionRotationSpeed Double Rotation Speed
RotationSpeedVsTime Table The rotation speed vs time point array
ReferDriveCycleCondition Int Refer drive cycle condition
- Convection Cooling(ConvectionCooling)
The convection cooling
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
ConvectionType Flag
0 or Forced
1 or Natural
2 or MixedThe flag for convection type
The forced convection type.
The natural convection type.
The mixed convection type.CoolantType Flag
0 or Air
1 or Water
2 or Oil
3 or ATF
4 or CustomThe flag for coolant type
Use air.
Use water.
Use oil.
Use ATF oil.
Use custom.Thermal Area Double The thermal area
CoolantTemperature Double The coolant temperature
CorrectionCoefficient Double The correction coefficient
ForcedConvectionType Flag
0 or Circumferential
1 or AxisDirection
2 or MotorGapThe flag for forced convection type
Use circumferential.
Use axis direction.
Use motor gap (radial).InputFlowType Flag
0 or FlowVelocity
2 or ReferenceFlowCircuitThe flag for input flow type
Use flow velocity.
Reference flow circuit.FlowVelocity Double The flow velocity
ReferenceFlowRateProbe Int The referenced flow rate probe id
PreviewFlowVelocity Double The flow velocity (preview)
GapWidth Double The gap width
RotorRadius Double The rotor radius
CharacteristicLengthForced Double The characteristic length (forced)
NaturalConvectionType Flag
0 or HorizontalCylinder
1 or VerticalCylinder
2 or VerticalFlatPlate
3 or HorizontalPlateUpper
4 or HorizontalPlateLowerThe flag for natural convection type
Use horizontal cylinder.
Use vertical cylinder.
Use vertical flat plate.
Use horizontal plate upper.
Use horizontal plate lower.CharacteristicLengthNatural Double The characteristic length (natural)
MixedDirectionType Flag
0 or AssistingOrTransverse
1 or OpposingThe flag for mixed direction type
Assisting or Transverse.
Opposing.TerminalTemperature Double The terminal temperature (preview)
CoolingMaterialTable Table The cooling material table
CoolantTemperatureType Flag
0 or Constant
1 or TerminalAverageValueThe flag for coolant temperature type
Use constant.
Refer to Terminal Average Value.CoolantSourceTemperature Double The cooling source temperature
PreviewCoolantTemperature Double The coolant temperature (preview)
HasFins Flag
0 or Off
1 or OnThe flag for fins
The surface does not have fins.
The surface has fins.FinInterval Double The fin interval
FinLength Double The fin length
FinHeight Double The fin height
FinNumber Flag The fin number
- Shaft Cooling(ShaftCooling)
The shaft cooling
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
InputFlowType Flag
0 or FlowVelocity
1 or VolumeFlowRate
2 or ReferenceFlowCircuitThe flag for input flow type
Use flow velocity.
Use volume flow rate.
Reference flow circuit.FlowVelocity Double The flow velocity
VolumeFlowRate Double The volume flow rate
ReferenceFlowRateProbe Int The referenced flow rate probe id
PreviewVolumeFlowRate Double The volume flow rate (preview)
PreviewFlowVelocity Double The flow velocity (preview)
ShaftCoolingType Flag
0 or NoShaftCooling
1 or HollowShaftCoolingThe flag for shaft cooling type
No Shaft Cooling
Hollow Shaft CoolingShaftLength Double The shaft length
ShaftRotorHeight Double The shaft rotor height
ShaftOuterRadius Double The shaft outer radius
ShaftInnerRadius Double The shaft inner radius
ShaftMassDensity Double The shaft mass density
ThermalConductivity Double The shaft thermal conductivity
ShaftCoolingSpecificHeat Double The shaft specific heat
ShaftCorrection Double The shaft correction coefficient
AdvectiveHeatTransportCorrection Double The advective heat transport correction coefficient
ShaftCoolantType Flag
1 or Water
2 or Oil
3 or ATFOil
4 or CustomThe flag for shaft coolant type
Use water.
Use oil.
Use ATF oil.
Use custom.CoolingMaterialTable Table The cooling material table
CoolantTemperatureConstantValue Double The coolant temperature constant value
CoolantTemperatureType Flag
0 or Constant
1 or TerminalAverageValueThe flag for coolant temperature type
Use constant.
Refer to Terminal Average Value.RotationSpeedType Flag
0 or Constant
1 or PointArray
2 or DriveCycleReferenceThe flag for rotation speed type
The constant type.
The point array type.
Reference ConditionRotationSpeed Double Rotation Speed
RotationSpeedVsTime Table The rotation speed vs time point array
SprayNozzleLocation Flag
0 or None
1 or BothSides
2 or FrontSide
3 or RearSideThe flag for spray nozzle location
No nozzle.
Both side nozzle.
Front side nozzle.
Rear side nozzle.CloseHollowShaftOutlet Flag
0 or Off
1 or OnThe flag for closing the hollow shaft outlet
Open the hollow shaft outlet
Close the hollow shaft outletFrontNozzleRatio Double The front nozzle ratio
RearNozzleRatio Double The rear nozzle ratio
ReferDriveCycleCondition Int Refer drive cycle condition
- Bearing(Bearing)
The bearing
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
ShaftDiameter Double The shaft diameter
BearingDiameter Double The bearing diameter
BearingWidth Double The bearing width
BearingResistanceCalculationType Flag
0 or Dimensions
1 or DimensionsAndGapThe type of bearing resistance calculation
From dimensions.
From dimensions and gapBearingEquivalentGapType Flag
0 or Custom
1 or Bearing1
2 or Bearing2The type of bearing resistance calculation
Use custom.
Use Bearing1 (0.2mm).
Use Bearing2 (0.4mm).BearingEquivalentGap Double The bearing equivalent gap
BearingGapConductivity Double The bearing gap thermal conductivity
ShaftBearingFitType Flag
0 or Custom
1 or GoodFit
2 or BadFitThe flag for shaft bearing fit type
Use custom.
Use good fit.
Use bad fit.ShaftBearingGap Double The shaft bearing gap
ShaftBearingThermalConductivity Double The shaft bearing thermal conductivity
BearingEndCapFitType Flag
0 or Custom
1 or GoodFit
2 or BadFitThe flag for bearing end cap fit type
Use custom.
Use good fit.
Use bad fit.BearingEndCapGap Double The bearing end cap gap
BearingEndCapThermalConductivity Double The bearing end cap thermal conductivity
BearingResistanceCorrectionCoefficient Double The correction coefficient of bearing thermal resistance
ShaftBearingResistanceCorrectionCoefficient Double The correction coefficient of shaft bearing thermal resistance
BearingEndCapResistanceCorrectionCoefficient Double The correction coefficient of bearing end cap thermal resistance
ExponentBearingInner Double The exponent of the bearing inner race loss function
ReferenceHeatGenerationBearingInner Double The heat generation amount at reference speed for the bearing inner loss function
ReferenceSpeedBearingInner Double The reference speed for the bearing inner loss function
ExponentBearingOuter Double The exponent of the bearing outer race loss function
ReferenceHeatGenerationBearingOuter Double The heat generation amount at reference speed for the bearing outer loss function
ReferenceSpeedBearingOuter Double The reference speed for the bearing outer loss function
SpeedSpecifyType Flag
0 or ConstantSpeed
1 or TimeDependentSpeedPointSequence
2 or ReferenceConditionThe flag for speed specify type
Constant Speed.
Time Dependent Speed Point Sequence
Reference Drive Cycle ConditionSpeed Double The speed of the bearing
SpeedVsTime Table The speed vs time point array
ReferDriveCycleCondition Int Refer drive cycle condition
- Thermal Circuit Control(HeatControl)
The heat control
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
InitialTemperature Double The initial temperature
HeatAnalysisTimeWidth Double The thermal circuit time width
- Heat Generation(HeatGeneration)
The heat generation
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
HeatGeneration Double The heat generation
GenerationType Flag
0 or Constant
1 or PointArray
3 or ReferCondition
4 or SpeedDependent
5 or ReferComponentThe flag for heat generation type
The constant type.
The temperature dependent type.
Refer to Heat Generation Component Condition.
The speed dependent type.
Refer to Heat Resistor Component.TempVsHeatGeneration Table The heat generation vs temperature point array
HeatGenerationRotationSpecifyType Flag
0 or BearingLossFunction
1 or PointArrayThe flag for heat generation speed specify type
The heat generation speed function type.
The heat generation speed point array type.FunctionExponent Double The function exponent
FunctionHeatGeneration Double The heat generation amount at a certain point
FunctionSpeed Double The speed at a certain point
HeatGenerationVsSpeed Table The heat generation vs speed point array
SpeedSpecifyType Flag
0 or ConstantSpeed
1 or PointArraySpeed
2 or ReferenceConditionThe flag for speed specify type
The constant speed type.
The speed time point array type.
Reference Drive Cycle ConditionSpeed Double The speed
SpeedVsTime Table The speed vs time point array
reference Int Reference component
ReferDriveCycleCondition Int Refer drive cycle condition
- Heat Transfer(HeatTransfer)
The heat transfer
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
HeatTransfer Double The heat transfer
ReferenceTemperature Double The reference temperature
HeatTransferCoefficientType Flag
0 or Constant
1 or PointArrayThe heat transfer coefficient type
The constant type.
The point array type.TempVsHeatTransfer Table The temperature vs thermal conductance point array
- Thermal Resistor(ThermalResistor)
The thermal resistor
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
ThermalResistor Double The thermal resistance
ResistanceType Flag
0 or Constant
1 or PointArray
3 or ThermalResistance
4 or ThermalResistanceCylindrical
5 or CoolingWaterJacket
6 or CoolingSpray
7 or CoolingATF
8 or CoolingForcedConvection
9 or CoolingNaturalConvection
10 or CoilAndCoreContact
11 or GeneralContact
12 or Suppress
13 or User-Defined
14 or ThermalResistanceAdvection
15 or ShaftCooling
16 or CoolingChannelThe flag for thermal resistance type
The constant type.
The point array type.
The thermal conduction type.
The thermal conduction cylindrical type.
The water jacket cooling type.
The spray cooling type.
The ATF cooling type.
The forced convection cooling type.
The natural convection cooling type.
The coil and core contact type.
The general contact type.
Suppress type
User-Defined type
The thermal resistance advection type.
The shaft cooling type
The cooling channel typeTempVsThermalResistance Table The thermal resistor vs temperature point array
ThermalResistorLength Double The thermal resistor length
ThermalResistorArea Double The thermal resistor area
ThermalResistorCylinderHeight Double The thermal resistor cylinder height
ThermalResistorOuterRadius Double The thermal resistor cylinder outer radius
ThermalResistorInnerRadius Double The thermal resistor cylinder inner radius
ThermalConductivity Double The thermal conductivity
ThermalCorrection Double The thermal correction coefficient
CustomInsulationThickness Double The custom insulation thickness
CustomWireDiameter Double The custom wire diameter
CustomFillFactor Double The custom fill factor
CustomTension Double The custom tension
CustomConductorLength Double The custom conductor length
CustomPressure Double The custom pressure
ContactType Flag
0 or RoundWire
1 or RectangularWireThe flag for contact type
The round wire type.
The rectangular wire type.ImpregnationType Flag
0 or Off
1 or OnThe flag for impregnation type
No impregnation.
Use impregnation.FitType Flag
0 or Custom
1 or GoodFit
2 or BadFitThe flag for fit type
Use custom.
Use good fit.
Use bad fit.CustomFit Double The custom fit length
CoolantType Flag
1 or Water
2 or Oil
4 or CustomThe flag for coolant type
Use water.
Use oil.
Use custom.ForcedConvectionCoolantType Flag
0 or Air
1 or Water
2 or Oil
4 or CustomThe flag for coolant type
Use air.
Use water.
Use oil.
Use custom.NaturalConvectionCoolantType Flag
0 or Air
1 or Water
2 or Oil
3 or ATFOil
4 or CustomThe flag for coolant type
Use air.
Use water.
Use oil.
Use ATF oil.
Use custom.AdvectionCoolantType Flag
1 or Water
2 or Oil
3 or ATFOil
4 or CustomThe flag for advection coolant type
Use water.
Use oil.
Use ATF oil.
Use custom.ATFCoolantType Flag
3 or ATFOil
4 or CustomThe flag for ATF coolant type
Use ATF oil.
Use custom.ChannelConvectionCoolantType Flag
0 or Air
1 or Water
2 or Oil
3 or ATFOil
4 or CustomThe flag for coolant type
Use air.
Use water.
Use oil.
Use ATF oil.
Use custom.Characteristic Length Double The characteristic length
InputFlowType Flag
0 or FlowVelocity
1 or VolumeFlowRate
2 or ReferenceFlowCircuitThe flag for input flow type
Use flow velocity.
Use volume flow rate.
Reference flow circuit.FlowVelocity Double The flow velocity
VolumeFlowRate Double The volume flow rate
NozzleDiameter Double The nozzle diameter
CoolingJacketType Flag
0 or Spiral
1 or Axial
2 or NoneThe flag for cooling jacket type
Use spiral.
Use axial.
None.CoolingJacketTubeWidth Double The rectangular tube width
CoolingJacketTubeHeight Double The rectangular tube height
NumCoolingJacketTubes Double The number of rectangular tubes
CoolingJacketRadius Double The cooling jacket radius
RectangularTubeLength Double The cooling jacket tube length
CoolingJacketArea Double The cooling jacket area
ForcedConvectionType Flag
0 or Circumferential
1 or AxisDirection
2 or MotorGap
3 or MotorGapAxialThe flag for forced convection type
Use circumferential.
Use axis direction.
Use motor gap (radial).
Use motor gap (axial).GapWidth Double The gap width
RotorRadius Double The rotor radius
NaturalConvectionType Flag
0 or HorizontalCylinder
1 or VerticalCylinder
2 or VerticalFlatPlate
3 or HorizontalPlateUpper
4 or HorizontalPlateLowerThe flag for natural convection type
Use horizontal cylinder.
Use vertical cylinder.
Use vertical flat plate.
Use horizontal plate upper.
Use horizontal plate lower.CoolingMaterialTable Table The cooling material table
CoolantTemperatureType Flag
0 or Constant
1 or TerminalAverageValueThe flag for coolant temperature type
Use constant.
Refer to Terminal Average Value.CoolantTemperatureConstantValue Double The coolant temperature constant value
PreviewCoolantTemperature Double The coolant temperature (preview)
PreviewTerminalTemperature1 Double The terminal temperature 1 (preview)
PreviewTerminalTemperature2 Double The terminal temperature 2 (preview)
ThermalUserDefinedScript String The python script for thermal resistance
ShaftLength Double The shaft length
ShaftCoolantType Flag
1 or Water
2 or Oil
3 or ATFOil
4 or CustomThe flag for shaft coolant type
Use water.
Use oil.
Use ATF oil.
Use custom.RotationSpeedType Flag
0 or Constant
1 or PointArray
2 or DriveCycleReferenceThe flag for rotation speed type
The constant type.
The point array type.
Reference ConditionRotationSpeed Double Rotation Speed
RotationSpeedVsTime Table The rotation speed vs time point array
GapFlowType Flag
0 or GapFlowVelocity
1 or GapRotationSpeedThe flag for gap flow type
Use flow velocity.
Use rotation speed.SprayType Flag
0 or GeneralSpray
1 or SpecifyNozzlePositionThe flag for spray type
Use general spray.
Specify nozzle position.NozzlePosition Flag
0 or SprayHousing
1 or SprayEndCap
2 or SprayShaftThe flag for nozzle position
Spray from housing.
Spray from end cap.
Spray from shaft.SprayAngle Double The spray angle
ShaftInnerRadius Double The shaft inner radius
ShaftOuterRadius Double The shaft outer radius
CoilInnerRadius Double The coil inner radius
CoilOuterRadius Double The coil outer radius
HousingInnerRadius Double The housing inner radius
CoilEndHeight Double The coil end height
EndCapDistance Double The end cap distance
AreaCorrectionType Flag
0 or AreaCorrectionFactor
1 or CoilEndAreaThe flag for area correction type
Use area correction factor.
Use coil end surface area.AreaCorrectionFactor Double The area correction factor
CoilEndArea Double The coil end area
ChannelType Flag
0 or CircleChannel
1 or RectangleChannelThe channel type
Circle type.
Rectangle type.CircularDiameter Double The circular diameter
NumberChannel Double The number of channel
ChannelLength Double The channel length
RotationFlag Flag
0 or NoConsideringRotation
1 or ConsideringRotationThe flag of considering rotation
Do not considering rotation.
Considering rotation.CircumferentiallyDistributedFlag Flag
0 or NoCircumferentiallyDistributed
1 or CircumferentiallyDistributedThe flag of circumferentially distributed
Do not circumferentially distributed.
Circumferentially distributed.RotationDiameter Double The rotation diameter
HasFins Flag
0 or Off
1 or OnThe flag for fins
The surface does not have fins.
The surface has fins.FinInterval Double The fin interval
FinLength Double The fin length
FinHeight Double The fin height
FinNumber Flag The fin number
ReferThermalProbe Flag
0 or Off
1 or OnReference thermal probe
Not refer to thermal probe.
Refer to thermal probe.ReferenceThermalProbe Int The referenced thermal probe id
ReferenceFlowRateProbe Int The referenced flow rate probe id
PreviewVolumeFlowRate Double The volume flow rate (preview)
PreviewFlowVelocity Double The flow velocity (preview)
UseAxialFlow Flag
0 or Off
1 or OnThe flag for use axial flow
Considering axial flow.
Does not consider axial flow.AxialInputFlowType Flag
0 or FlowVelocity
1 or VolumeFlowRate
2 or ReferenceFlowCircuitThe flag for axial input flow type
Use flow velocity.
Use volume flow rate.
Reference flow circuit.AxialFlowVelocity Double The axial flow velocity
AxialVolumeFlowRate Double The axial volume flow rate
AxialLength Double The axial length
AxialReferenceFlowRateProbe Int The axial referenced flow rate probe id
ReferDriveCycleCondition Int Refer drive cycle condition
- Cooling Jacket(CoolingJacket)
The cooling jacket
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
InputFlowType Flag
0 or FlowVelocity
1 or VolumeFlowRate
2 or ReferenceFlowCircuitThe flag for input flow type
Use flow velocity.
Use volume flow rate.
Reference flow circuit.FlowVelocity Double The flow velocity
VolumeFlowRate Double The volume flow rate
CoolingJacketType Flag
0 or Spiral
1 or Axial
2 or NoneThe flag for cooling jacket type
Use spiral.
Use axial.
None.CoolingJacketTubeWidth Double The rectangular tube width
CoolingJacketTubeHeight Double The rectangular tube height
NumCoolingJacketTubes Double The number of rectangular tubes
CoolingJacketRadius Double The cooling jacket radius
RectangularTubeLength Double The cooling jacket tube length
CoolingJacketArea Double The cooling jacket area
ThermalCorrection Double The thermal correction coefficient
ReferenceFlowRateProbe Int The referenced flow rate probe id
PreviewVolumeFlowRate Double The volume flow rate (preview)
PreviewFlowVelocity Double The flow velocity (preview)
AdvectionThermalCorrection Double The advection thermal correction coefficient
CoolantType Flag
1 or Water
2 or Oil
4 or CustomThe flag for coolant type
Use water.
Use oil.
Use custom.CoolingMaterialTable Table The cooling material table
CoolantTemperatureType Flag
0 or Constant
1 or TerminalAverageValueThe flag for coolant temperature type
Use constant.
Refer to Terminal Average Value.CoolantTemperatureConstantValue Double The coolant temperature constant value
ResolutionOfTemperatureDistribution Flag The resolution of temperature distribution
- Heat Capacity(HeatCapacity)
The heat capacity
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
HeatCapacity Double The heat capacity
CapacityType Flag
0 or Constant
1 or PointArray
3 or HeatCapacityThe flag for heat capacity type
The constant type.
The point array type.
The heat capacity type.TempVsHeatCapacity Table The heat capacity vs temperature point array
ThermalCapacitanceDensity Double The thermal capacitance density
ThermalCapacitanceSpecificHeat Double The thermal capacitance specific heat
ThermalCapacitanceVolume Double The thermal capacitance volume
ThermalCorrection Double The thermal correction coefficient