- HSCommonNonDMP(HSCommonNonDMP)
HSCommonNonDMP properties
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
UseMultiCPU Flag
0 or NonParallel
0 or Off
1 or SMP
1 or OnFlag for the use of multi cpu
Do not use multi cpu
Do not use multi cpu
Use SMP
Use SMPMultiCPU Flag Degree of parallelism for SMP
- Study Properties(HeatStressControl)
HeatStressControl properties
Property
(propName)Type
(Type)Flag
(scriptKeyName)Description
IccgAccel Double The value of acceleration coefficient
IccgTolerance Double The value of convergence tolerance
IccgMaxIteration Flag The value of max iteration
NonlinearMaxIteration Flag The number of nonlinear iteration
NonlinearTolerance Double The value of nonlinear iterative convergence tolerance
Coupling Flag
0 or Off
1 or OnThe flag for coupling analysis
The coupling analysis is not executed.
The coupling analysis is executed.UsrsubName String The user subroutine name
UsrArraySize Flag The size of users subroutine point array
Temperature Flag
0 or Off
1 or OnThe flag for output temperature
Not output the temperature.
Output the temperature.HeatFlux Flag
0 or Off
1 or OnThe flag for output heat flux
Not output the heat flux.
Output the heat flux.HeatGenerationDensity Flag
0 or Off
1 or OnThe flag for output heat source density
Not output the heat source density.
Output the heat source density.HeatTransferCoefficient Flag
0 or Off
1 or OnThe flag for output heat transfer coefficient
Not output the heat transfer coefficient.
Output the heat transfer coefficient.Stress Flag
0 or Off
1 or OnThe flag for output stress
Not output the stress.
Output the stress.Strain Flag
0 or Off
1 or OnThe flag for output strain
Not output the strain.
Output the strain.Force Flag
0 or Off
1 or OnThe flag for output force
Not output the force.
Output the force.SolverReportFile Flag
0 or Off
1 or OnThe flag for output solver report file
Not output the solver report file.
Output the solver report file.PartialModelConversion Flag
0 or Off
1 or OnThe flag to treat as full model.
The input value is not converted as a partial model.
The input value is converted as a partial model.ConversionFactor Double Conversion factor excluding periodic boundary
OutputTimingSameStep Flag
0 or Off
1 or OnFlag to use same step by table and field results
Output another step by table and field results
Output same step by table and field resultsTimeSteppingScheme Flag
0 or ImplicitMethod
1 or FullyImplicitMethodThe flag for implicit method type
Use implicit method.
Use fully implicit methodThermalStressConvergenceTolerance Double The nonlinear convergence tolerance
ThermalStressLoadControl Flag
0 or Manual
1 or AutoThe load control.
The manual control.
The automatic control.ThermalStressMaxIterations Flag The maximum number of non linear iterations
ThermalStressLoadIncrements Flag The value of non linear load increments
ThermalStressTargetIterations Flag The target iterations
ThermalStressUseModifiedNewtonRaphson Flag
0 or Off
1 or OnThe flag of modified Newton-Raphson
Not using modified Newton-Raphson.
Use modified Newton-RaphsonThermalStressModifiedNewtonRaphsonMaxIterations Flag The maximum number of Newton-Raphson iterations
ThermalStressModifiedNewtonRaphsonConvergenceTolerance Double The Newton-Raphson convergence tolerance
ThermalStressContactMethod Flag
0 or Penalty
1 or AugmentedLagrangianThe contact method.
The penalty contact method.
The augmented lagrangian method.ThermalStressNormalAugmentation Flag
0 or Off
1 or OnThe flag to augment normal contact force.
The normal contact force is not augmented.
The normal contact force is augmented.ThermalStressTangentialAugmentation Flag
0 or Off
1 or OnThe flag to augment tangential contact force.
The tangential contact force is not augmented.
The tangential contact force is augmented.ThermalStressContactTolerance Double The contact convergence tolerance
ThermalStressContactMaxIteration Flag The maximum number of contact iterations
ThermalStressApplyAutoLoad Flag
0 or Off
1 or OnThe flag to apply auto load
Do not apply auto load
Apply auto loadThermalStressUseIterativePenaltyFactorAdjustment Flag
0 or OFF
1 or ONThe flag to use iterative penalty factor adjustment.
Don't use iterative penalty factor adjustment.
Use iterative penalty factor adjustment.ThermalStressAutoLoadInitFactor Double The initial factor of auto load-increment
ThermalStressAutoLoadRatio Double The common ratio of auto load-increment
ThermalStressContactForce Flag
0 or Off
1 or OnThe flag for output of contact force results
The contact force result won't be put into a result file
The contact force result will be put into a result fileThermalStressContactPressure Flag
0 or Off
1 or OnThe flag for output contact pressure result
Not output the contact pressure.
Output the contact pressure.ThermalStressPlasticStrain Flag
0 or Off
1 or OnThe flag for output of plastic strain results
The plastic strain result won't be put into a result file
The plastic strain result will be put into a result fileCsvOutputPath String The output path for the csv files
CsvResultTypes String The list of result types to output the csv files
CsvOutputResponseData Flag CSV file output response value
CsvOutputInductanceData Flag CSV file output efficiency map inductance values
CsvOutputProbe Flag CSV file output probe value
CsvOutputSection Flag CSV file output section graph value
CsvOutputCalculation Flag CSV file output calculation value
CsvOutputObjectiveData Flag CSV file output objective value
CsvComponentType Flag
0 or RealImaginary
1 or AmplitudePhase
2 or RMSFlag of component output type
Output real and imaginary
Output amplitude and phase
Output rmsCsvDivisionType Flag
0 or Off
1 or OnFlag of divide CSV file output by specified number of cases
Do not divide
Divide CSV outputCsvDivisionCase Flag Specified number of cases
OutputControlType Flag
0 or SpecifyOutputResultItems
1 or OutputTableOnly
2 or DeleteResultFilesThe output control type
Specify Result Items to be Output.
Output only table results.
Delete result files.LogOutputLevel Flag
0 or Debug
1 or Information
2 or Warning
3 or ErrorThe log output level
Debug
Information
Warning
Error