Component Properties for Electrical Circuit


Electric Potential Source(1 terminal)(VoltageSource)

Electric Potential Source(1 terminal)

Property
(propName)
Type
(Type)
Flag
(scriptKeyName)

Description

FunctionType Flag
0 or PointArray
1 or Sin
2 or Exp
3 or Constant
4 or Pulse
5 or Step

The flag for function type.
The point array type.
The sin function type.
The expotential function type.
The constant type.
The pulse function type.
The step function type.

XType Flag
1 or Time
6 or Step
9 or UserSub

Axis Type
Time Axis
Step Axis
Use user-subroutine.

Periodic Flag
0 or On
1 or Off

Flag for Periodic Iteration
Periodic Iteration
Non Periodic Iteration

userid Flag

The user subroutine ID.

Time Table

Voltage versus Time Table

Angle Table

Voltage versus Angle Table

Step Table

Voltage versus Step Table

Position Table

The voltage vs displacement point array

UseVoltageManualSetting Flag
0 or Off
1 or On

Use voltage manual setting or not
Not using voltage manual setting
Using voltage manual setting

VoltageAmplitude Double

Pseudo steady state voltage amplitude

VoltagePhase Double Pseudo steady state voltage phase

Three-phase Electric Potential Source(3PhaseVoltageSource)

Three-phase Electric Potential Source

Property
(propName)
Type
(Type)
Flag
(scriptKeyName)

Description

XType Flag
1 or Time
6 or Step

Axis Type
Time Axis
Step Axis

VoltageSpecifyType Flag
0 or UseTerminalPotential
1 or UseLineVoltage

The specified voltage type
Use terminal potential.
Use line voltage.

VoltageValueType Flag
0 or UseAmplitude
1 or UseRMS

Peak Type
Use amplitude.
Use rms.

Amplitude Double

Amplitude Value / RMS Value

Frequency Double

Frequency

PhaseU Double

Phase of U-Phase

CommutatingSequence Flag
0 or UVW
1 or UWV

Commutating Sequence Type
The commutating sequence is U-V-W.
The commutating sequence is U-W-V.

PeriodicStep Double

The mechanical periodic step.

PeriodicAngle Double

The mechanical periodic angle.

Stroke Double The periodic stroke.

Multi Phase Electric Potential Source(MultiPhaseVoltageSource)

The multi phase voltage source

Property
(propName)
Type
(Type)
Flag
(scriptKeyName)

Description

XType Flag
1 or Time
6 or Step

Axis Type
Time Axis
Step Axis

NumPhases Flag

The number of phases

PhaseWindingType Flag
0 or NPhaseWinding
1 or Multi3PhaseWinding

The phase winding type
Use N-phase electric potential source.
Use (N/3)x 3-phase electric potential source.

VoltageValueType Flag
0 or UseAmplitude
1 or UseRMS

Peak Type
Use amplitude.
Use rms.

Amplitude Double

Amplitude Value / RMS Value

Frequency Double

Frequency

ReferencePhase Double

The phase of U-Phase/1-Phase

PhaseDifference Double

The phase difference

CommutatingSequence Flag
0 or UVW
1 or UWV

Commutating Sequence Type
The commutating sequence is U-V-W.
The commutating sequence is U-W-V.

PeriodicStep Double

The mechanical periodic step.

PeriodicAngle Double

The mechanical periodic angle.

Stroke Double The periodic stroke.

Electric Potential Source(2 terminals)(TwoTerminalVoltageSource)

Electric Potential Source (2 terminals)

Property
(propName)
Type
(Type)
Flag
(scriptKeyName)

Description

FunctionType Flag
0 or PointArray
1 or Sin
2 or Exp
3 or Constant
4 or Pulse
5 or Step

The flag for function type.
The point array type.
The sin function type.
The expotential function type.
The constant type.
The pulse function type.
The step function type.

XType Flag
1 or Time
6 or Step

Axis Type
Time Axis
Step Axis

Periodic Flag
0 or On
1 or Off

Flag for Periodic Iteration
Periodic Iteration
Non Periodic Iteration

Time Table

Voltage versus Time Table

Angle Table

Voltage versus Angle Table

Step Table

Voltage versus Step Table

Position Table

The voltage vs displacement point array

UseVoltageManualSetting Flag
0 or Off
1 or On

Use voltage manual setting or not
Not using voltage manual setting
Using voltage manual setting

VoltageAmplitude Double

Pseudo steady state voltage amplitude

VoltagePhase Double Pseudo steady state voltage phase

Control Voltage Source(2 terminals)(ControlTwoTerminalVoltageSource)

The control two terminal voltage source

Property
(propName)
Type
(Type)
Flag
(scriptKeyName)

Description

UseVoltageManualSetting Flag
0 or Off
1 or On

Use voltage manual setting or not
Not using voltage manual setting
Using voltage manual setting

VoltageAmplitude Double

Pseudo steady state voltage amplitude

VoltagePhase Double Pseudo steady state voltage phase

Control Voltage Source(1 terminal)(ControlVoltageSource)

The control voltage source

Property
(propName)
Type
(Type)
Flag
(scriptKeyName)

Description

UseVoltageManualSetting Flag
0 or Off
1 or On

Use voltage manual setting or not
Not using voltage manual setting
Using voltage manual setting

VoltageAmplitude Double

Pseudo steady state voltage amplitude

VoltagePhase Double Pseudo steady state voltage phase

Power Source(PowerSource)

The power source

Property
(propName)
Type
(Type)
Flag
(scriptKeyName)

Description

FunctionType Flag
0 or PointArray
1 or Constant

The flag for function type.
The point array type.
The constant type.

ConstantPower Double

The constant power

PowerVsTime Table

The power vs time point array

MaxVoltage Double

The max voltage

MaxCurrent Double The max current

Current Source(1 terminal)(CurrentSource)

Current Source(1 terminal)

Property
(propName)
Type
(Type)
Flag
(scriptKeyName)

Description

FunctionType Flag
0 or PointArray
1 or Sin
2 or Exp
3 or Constant
4 or Pulse
5 or Step
8 or Harmonic

The flag for function type.
The point array type.
The sin function type.
The expotential function type.
The constant type.
The pulse function type.
The step function type.
The harmonic type.

XType Flag
1 or Time
6 or Step
9 or UserSub

Axis Type
Time Axis
Step Axis
Use user-subroutine.

Periodic Flag
0 or On
1 or Off

Flag for Periodic Iteration
Periodic Iteration
Non Periodic Iteration

userid Flag

The user subroutine ID.

Time Table

Current versus Time Table

Angle Table

Current versus Angle Table

Step Table

Current versus Step Table

Position Table

The current vs displacement point array

UseCurrentManualSetting Flag
0 or Off
1 or On

Use current manual setting or not
Not using current manual setting
Using current manual setting

CurrentAmplitude Double

Pseudo steady state current amplitude

CurrentPhase Double Pseudo steady state current phase

Three-phase Current Source(3PhaseCurrentSource)

Three-phase Current Source

Property
(propName)
Type
(Type)
Flag
(scriptKeyName)

Description

XType Flag
1 or Time
6 or Step

Axis Type
Time Axis
Step Axis

CurrentValueType Flag
0 or UseAmplitude
1 or UseRMS

Peak Type
Use amplitude.
Use rms.

Amplitude Double

Amplitude Value / RMS Value

Frequency Double

Frequency

PhaseU Double

Phase of U-Phase

CommutatingSequence Flag
0 or UVW
1 or UWV

Commutating Sequence Type
The commutating sequence is U-V-W.
The commutating sequence is U-W-V.

PeriodicStep Double

The mechanical periodic step.

PeriodicAngle Double

The mechanical periodic angle.

Stroke Double The periodic stroke.

Multi Phase Current Source(MultiPhaseCurrentSource)

The multi phase current source

Property
(propName)
Type
(Type)
Flag
(scriptKeyName)

Description

XType Flag
1 or Time
6 or Step

Axis Type
Time Axis
Step Axis

NumPhases Flag

The number of phases

PhaseWindingType Flag
0 or NPhaseWinding
1 or Multi3PhaseWinding

The phase winding type
Use N-phase current source.
Use (N/3)x 3-phase current source.

CurrentValueType Flag
0 or UseAmplitude
1 or UseRMS

Peak Type
Use amplitude.
Use rms.

Amplitude Double

Amplitude Value / RMS Value

Frequency Double

Frequency

ReferencePhase Double

The phase of U-Phase/1-Phase

PhaseDifference Double

The phase difference

CommutatingSequence Flag
0 or UVW
1 or UWV

Commutating Sequence Type
The commutating sequence is U-V-W.
The commutating sequence is U-W-V.

PeriodicStep Double

The mechanical periodic step.

PeriodicAngle Double

The mechanical periodic angle.

Stroke Double The periodic stroke.

Current Source(2 terminals)(TwoTerminalCurrentSource)

Current Source(2 terminals)

Property
(propName)
Type
(Type)
Flag
(scriptKeyName)

Description

FunctionType Flag
0 or PointArray
1 or Sin
2 or Exp
3 or Constant
4 or Pulse
5 or Step
8 or Harmonic

The flag for function type.
The point array type.
The sin function type.
The expotential function type.
The constant type.
The pulse function type.
The step function type.
The harmonic type.

XType Flag
1 or Time
6 or Step

Axis Type
Time Axis
Step Axis

Periodic Flag
0 or On
1 or Off

Flag for Periodic Iteration
Periodic Iteration
Non Periodic Iteration

Time Table

Current versus Time Table

Angle Table

Current versus Angle Table

Step Table

Current versus Step Table

Position Table

The current vs displacement point array

UseCurrentManualSetting Flag
0 or Off
1 or On

Use current manual setting or not
Not using current manual setting
Using current manual setting

CurrentAmplitude Double

Pseudo steady state current amplitude

CurrentPhase Double Pseudo steady state current phase

Control Current Source(2 terminals)(ControlTwoTerminalCurrentSource)

The control two terminal current source

Property
(propName)
Type
(Type)
Flag
(scriptKeyName)

Description

UseCurrentManualSetting Flag
0 or Off
1 or On

Use current manual setting or not
Not using current manual setting
Using current manual setting

CurrentAmplitude Double

Pseudo steady state current amplitude

CurrentPhase Double Pseudo steady state current phase

Control Current Source(1 terminal)(ControlCurrentSource)

The control current source

Property
(propName)
Type
(Type)
Flag
(scriptKeyName)

Description

UseCurrentManualSetting Flag
0 or Off
1 or On

Use current manual setting or not
Not using current manual setting
Using current manual setting

CurrentAmplitude Double

Pseudo steady state current amplitude

CurrentPhase Double Pseudo steady state current phase

Diode(Diode)

Diode

Property
(propName)
Type
(Type)
Flag
(scriptKeyName)

Description

InitialVoltage Double

Initial voltage

MaxResistance Double

Maximum Resistance

MinResistance Double

Minimum Resistance

k Double

Coefficient k for Logarithm Function

SaturationCurrent Double

Saturation Current

Type Flag
0 or PointArray
1 or Function

The flag for type.
The type is point array.
The type is function.

voltage Table Current vs Voltage Table

User Subroutine(UserSubroutine)

The user subroutine

Property
(propName)
Type
(Type)
Flag
(scriptKeyName)

Description

UserParameter Flag The user parameter

Switch(Switch)

Switch

Property
(propName)
Type
(Type)
Flag
(scriptKeyName)

Description

InitialState Flag
0 or Off
1 or On

Initial state
The initial state is off.
The initial state is on.

XType Flag
1 or Time
6 or Step
11 or Current
12 or Voltage
13 or Hysteresis

Axis Type
Time Axis
Step Axis
The switch is current dependent.
The switch is voltage dependent.
The hysteresis band.

reference Int

Reference component

terminal1 Int

Reference Probe 1

terminal2 Int

Reference Probe 2

TimingType Flag
1 or PointArray
2 or Parameter

The flag for timing type.
The timing type is point array.
The timing type is parameter.

Period Double

One Period

t1 Double

First Switching Time in One Period

t2 Double

Second Switching Time in One Period

InitialOpenState Flag
0 or Off
1 or On

The initial open state
The initial open state is off.
The initial open state is on.

Time Table

Time Table

Angle Table

Angle Table

Step Table

Step Table

Position Table

The value vs displacement point array

Current Table

The value vs current point array

Voltage Table

The value vs voltage point array

Periodic Flag
0 or On
1 or Off

Flag for Periodic Iteration
Periodic Iteration
Non Periodic Iteration

BandType Flag
0 or BaseWidth
1 or MaxMin

The hysteresis band type
Setting current base and current width.
Setting current max and current min.

CurrentBase Double

The hysteresis band current base

CurrentWidth Double

The hysteresis band current width

CurrentMax Double

The hysteresis band current max

CurrentMin Double The hysteresis band current min

Control Switch(ControlSwitch)

The control switch

Property
(propName)
Type
(Type)
Flag
(scriptKeyName)

Description

InitialState Flag
0 or Off
1 or On
Initial state
The initial state is off.
The initial state is on.

FEA(FEAControlBlock)

The FEA control block

Property
(propName)
Type
(Type)
Flag
(scriptKeyName)

Description

FEAReferenceStudy String The reference study for FEA block

FEM Coil(Coil)

FEM Coil

Property
(propName)
Type
(Type)
Flag
(scriptKeyName)

Description

Turn Double

Number of Turns of the Coil

Resistance Double

Resistance of the Coil

LeakageInductance Double

The leakage inductance of the coil

Temperature Double

The temperature

TempVsRes Table

The resistor vs temperature point array

TimeVsTemp Table

The temperature vs time point array

TemperatureDependentType Flag
0 or PointArray
1 or TemperatureDependentCorrection

Resistance Setting Type
The point array type.
The temperture dependent correction type.

BaseTemperatureResistance Double

The base temperature resistance

BaseTemperature Double

The base temperature

TemperatureCoefficient Double

The temperature factor

AverageTemperatureName String

The Average Temperature Name

XType Flag
9 or Temperature
10 or Constant

Axis Type
The temperature axis.
The constant axis

TemperatureType Flag
0 or Constant
1 or PointSequence
2 or Coupling
The temperature type
The constant type
The point sequence type
The coupling type

Reference FEM Coil(ReferenceCoil)

The reference coil

Property
(propName)
Type
(Type)
Flag
(scriptKeyName)

Description

Reference Int

The reference id

Periodic Flag
-1 or Reverse
1 or Normal
The periodic type
The reverse orientation
The basic orientation

Three Terminal Coil(ThreeTerminalCoil)

The three terminal coil

Property
(propName)
Type
(Type)
Flag
(scriptKeyName)

Description

Turn Double

Number of Turns of the Coil

Resistance Double

Resistance of the Coil

LeakageInductance Double

The leakage inductance of the coil

TempVsRes Table

The resistor vs temperature point array

TemperatureDependentType Flag
0 or PointArray
1 or TemperatureDependentCorrection

Resistance Setting Type
The point array type.
The temperture dependent correction type.

BaseTemperatureResistance Double

The base temperature resistance

BaseTemperature Double

The base temperature

TemperatureCoefficient Double

The temperature factor

XType Flag
9 or Temperature
10 or Constant
Axis Type
The temperature axis.
The constant axis

Coupling Control(CouplingControl)

The coupling control

Property
(propName)
Type
(Type)
Flag
(scriptKeyName)

Description

NumberOfThermalCircuitCalcPerMag Flag

The number of thermal circuit calculation per magnetic field analysis

UseAverageSteps Flag
0 or Off
1 or On

Use average steps for loss or not
Not using average steps for loss
Using average steps for loss

AverageSteps Flag

The average steps for loss

RunThermalMode Flag
0 or SyncThermal
1 or AfterThermal

Method of thermal circuit analysis
Thermal circuit analysis in synchronization with magnetic field analysis
Thermal circuit analysis after magnetic field analysis

RunIronLoss Flag
0 or Off
1 or On

Iron loss analysis in synchronization with magnetic field analysis
Do not perform iron loss analysis
Perform iron loss analysis

PostProcessingSteps Flag

Number of steps after post-processing

FrequencyPerOneMagAnalysis Flag

The frequency for control analysis per one magnetic analysis

UnitForWhenToStartMag Flag
0 or TimeBeforeMagneticFieldAnalysis
1 or StepsBeforeMagneticFieldAnalysis
2 or SteadyStateMagneticFieldAnalysis

Unit for when to start magnetic field analysis
Execute magnetic field analysis after specified time
Execute magnetic field analysis after specified steps
Execute magnetic field analysis after reaching steady state

StepToStartMag Flag

Start magnetic field analysis after step

TimeToStartMag Double

Start magnetic field analysis after time

SignalProbeReference Int

Signal Probe reference id

SteadyStateFrequency Double

Steady state frequency

SteadyStateTolerance Double

Steady state tolerance

StopMagAnalysisFlag Flag
0 or UseStepControl
1 or UseSpecifiedTime

Stop magnetic analysis flag
Use step control
Use user specified time

PeriodToRunAnalysis Double

Period to run analysis

SteadyStateStopCheckMethod Flag
0 or Maximum
1 or MovingAverage
The stop method used for the steady state
Maximum value
Moving average

Brush / Commutator(BrushCommutator)

Brush Motor Component

Property
(propName)
Type
(Type)
Flag
(scriptKeyName)

Description

BrushDivideMultiplier Flag

The number of divider

Brushes Flag

The number of brushes

Segments Flag

Commutator Segments

BrushWidth Double

Brush Width

SlitWidth Double

Slit Width

InitialAngle Double

Initial Angle

ContactResistance Double

Contact Resistance between Brush and Commutator

UseArcVoltage Flag
0 or Off
1 or On

Flag to Allow Arc Voltage
Arc voltage is not used.
Arc voltage is used.

ArcVoltage Double

Arc Voltage

SparkoverVoltage Double

Sparkover Voltage

EachBrush Flag
0 or Off
1 or On

The flag to set detail
The all brush is set.
The each brush is set.

UseResistanceTable Flag
0 or Off
1 or On

The flag to allow resistance table
The resistance table is not used.
The resistance table is used.

ContactAngleRatioVsAreaRatio Table

The area ratio vs contact angle ratio point array

BrushWidth1 Double

The brush1 width

ContactResistance1 Double

The contact resistance between brush1 and commutator

UseBrushTable1 Flag
0 or Off
1 or On

The flag to allow resistance table
The brush table1 is not used.
The brush table1 is used.

ContactAngleRatioVsAreaRatio1 Table

The area ratio vs contact angle ratio point array1

BrushPosition1 Double

The Brush1 Position

BrushWidth2 Double

The brush2 width

ContactResistance2 Double

The contact resistance between brush2 and commutator

UseBrushTable2 Flag
0 or Off
1 or On

The flag to allow resistance table
The brush table2 is not used.
The brush table2 is used.

ContactAngleRatioVsAreaRatio2 Table

The area ratio vs contact angle ratio point array2

BrushPosition2 Double

The Brush2 Position

BrushWidth3 Double

The brush3 width

ContactResistance3 Double

The contact resistance between brush3 and commutator

UseBrushTable3 Flag
0 or Off
1 or On

The flag to allow resistance table
The brush table3 is not used.
The brush table3 is used.

ContactAngleRatioVsAreaRatio3 Table

The area ratio vs contact angle ratio point array3

BrushPosition3 Double

The Brush3 Position

BrushWidth4 Double

The brush4 width

ContactResistance4 Double

The contact resistance between brush4 and commutator

UseBrushTable4 Flag
0 or Off
1 or On

The flag to allow resistance table
The brush table4 is not used.
The brush table4 is used.

ContactAngleRatioVsAreaRatio4 Table

The area ratio vs contact angle ratio point array4

BrushPosition4 Double

The Brush4 Position

BrushWidth5 Double

The brush5 width

ContactResistance5 Double

The contact resistance between brush5 and commutator

UseBrushTable5 Flag
0 or Off
1 or On

The flag to allow resistance table
The brush table5 is not used.
The brush table5 is used.

ContactAngleRatioVsAreaRatio5 Table

The area ratio vs contact angle ratio point array5

BrushPosition5 Double

The Brush5 Position

BrushWidth6 Double

The brush6 width

ContactResistance6 Double

The contact resistance between brush6 and commutator

UseBrushTable6 Flag
0 or Off
1 or On

The flag to allow resistance table
The brush table6 is not used.
The brush table6 is used.

ContactAngleRatioVsAreaRatio6 Table

The area ratio vs contact angle ratio point array6

BrushPosition6 Double

The Brush6 Position

BrushWidth7 Double

The brush7 width

ContactResistance7 Double

The contact resistance between brush7 and commutator

UseBrushTable7 Flag
0 or Off
1 or On

The flag to allow resistance table
The brush table7 is not used.
The brush table7 is used.

ContactAngleRatioVsAreaRatio7 Table

The area ratio vs contact angle ratio point array7

BrushPosition7 Double

The Brush7 Position

BrushWidth8 Double

The brush8 width

ContactResistance8 Double

The contact resistance between brush8 and commutator

UseBrushTable8 Flag
0 or Off
1 or On

The flag to allow resistance table
The brush table8 is not used.
The brush table8 is used.

ContactAngleRatioVsAreaRatio8 Table

The area ratio vs contact angle ratio point array8

BrushPosition8 Double

The Brush8 Position

BrushWidth9 Double

The brush9 width

ContactResistance9 Double

The contact resistance between brush9 and commutator

UseBrushTable9 Flag
0 or Off
1 or On

The flag to allow resistance table
The brush table9 is not used.
The brush table9 is used.

ContactAngleRatioVsAreaRatio9 Table

The area ratio vs contact angle ratio point array9

BrushPosition9 Double

The Brush9 Position

BrushWidth10 Double

The brush10 width

ContactResistance10 Double

The contact resistance between brush10 and commutator

UseBrushTable10 Flag
0 or Off
1 or On

The flag to allow resistance table
The brush table10 is not used.
The brush table10 is used.

ContactAngleRatioVsAreaRatio10 Table

The area ratio vs contact angle ratio point array10

BrushPosition10 Double

The Brush10 Position

BrushWidth11 Double

The brush11 width

ContactResistance11 Double

The contact resistance between brush11 and commutator

UseBrushTable11 Flag
0 or Off
1 or On

The flag to allow resistance table
The brush table11 is not used.
The brush table11 is used.

ContactAngleRatioVsAreaRatio11 Table

The area ratio vs contact angle ratio point array11

BrushPosition11 Double

The Brush11 Position

BrushWidth12 Double

The brush12 width

ContactResistance12 Double

The contact resistance between brush12 and commutator

UseBrushTable12 Flag
0 or Off
1 or On

The flag to allow resistance table
The brush table12 is not used.
The brush table12 is used.

ContactAngleRatioVsAreaRatio12 Table

The area ratio vs contact angle ratio point array12

BrushPosition12 Double

The Brush12 Position

BrushWidth13 Double

The brush13 width

ContactResistance13 Double

The contact resistance between brush13 and commutator

UseBrushTable13 Flag
0 or Off
1 or On

The flag to allow resistance table
The brush table13 is not used.
The brush table13 is used.

ContactAngleRatioVsAreaRatio13 Table

The area ratio vs contact angle ratio point array13

BrushPosition13 Double

The Brush13 Position

BrushWidth14 Double

The brush14 width

ContactResistance14 Double

The contact resistance between brush14 and commutator

UseBrushTable14 Flag
0 or Off
1 or On

The flag to allow resistance table
The brush table14 is not used.
The brush table14 is used.

ContactAngleRatioVsAreaRatio14 Table

The area ratio vs contact angle ratio point array14

BrushPosition14 Double

The Brush14 Position

BrushWidth15 Double

The brush15 width

ContactResistance15 Double

The contact resistance between brush15 and commutator

UseBrushTable15 Flag
0 or Off
1 or On

The flag to allow resistance table
The brush table15 is not used.
The brush table15 is used.

ContactAngleRatioVsAreaRatio15 Table

The area ratio vs contact angle ratio point array15

BrushPosition15 Double

The Brush15 Position

BrushWidth16 Double

The brush16 width

ContactResistance16 Double

The contact resistance between brush16 and commutator

UseBrushTable16 Flag
0 or Off
1 or On

The flag to allow resistance table
The brush table16 is not used.
The brush table16 is used.

ContactAngleRatioVsAreaRatio16 Table

The area ratio vs contact angle ratio point array16

BrushPosition16 Double The Brush16 Position

Inductor(Inductor)

Inductor

Property
(propName)
Type
(Type)
Flag
(scriptKeyName)

Description

Inductance Double Inductance

Reference FEM Conductor(ReferenceConductor)

The reference conductor

Property
(propName)
Type
(Type)
Flag
(scriptKeyName)

Description

Reference Int

The reference id

Periodic Flag
-1 or Reverse
1 or Normal
The periodic type
The reverse orientation
The basic orientation

Capacitor(Capacitor)

Capacitor

Property
(propName)
Type
(Type)
Flag
(scriptKeyName)

Description

Capacitance Double Capacitance

Resistor(Resistor)

Resistor

Property
(propName)
Type
(Type)
Flag
(scriptKeyName)

Description

Resistance Double

Resistance

XType Flag
1 or Time
6 or Step
9 or Temperature
10 or Constant
11 or Current
12 or Voltage

Axis Type
Time Axis
Step Axis
The temperature axis.
The constant axis.
The resistor is current dependent.
The resistor is voltage dependent.

Periodic Flag
0 or On
1 or Off

Flag for Periodic Iteration
Periodic Iteration
Non Periodic Iteration

Temperature Double

The temperature

InitialResistance Double

The initial resistance

reference Int

Reference component

terminal1 Int

Reference Probe 1

terminal2 Int

Reference Probe 2

TimeVsRes Table

The resistor vs time point array

StepVsRes Table

The resistor vs step point array

AngleVsRes Table

The resistor vs angle point array

DispVsRes Table

The resistor vs displacement point array

TempVsRes Table

The resistor vs temperature point array

TimeVsTemp Table

The temperature vs time point array

CurrentVsRes Table

The current resistor point array

VoltageVsRes Table

The voltage resistor point array

AverageTemperatureName String

The Average Temperature Name

TemperatureDependentType Flag
0 or PointArray
1 or TemperatureDependentCorrection

Resistance Setting Type
The point array type.
The temperature dependent correction type.

BaseTemperatureResistance Double

The base temperature resistance

BaseTemperature Double

The base temperature

TemperatureCoefficient Double

The temperature factor

IncludeResistanceLoss Flag
0 or Off
1 or On

Include resistance loss in circuit loss
Not including resistance loss in circuit loss.
Including resistance loss in circuit loss.

TemperatureType Flag
0 or Constant
1 or PointArray
The flag of temperature setting type
The constant type
The point array type

Three Terminal Resistor(ThreeTerminalResistor)

The three terminal resistor

Property
(propName)
Type
(Type)
Flag
(scriptKeyName)

Description

Resistance Double

Resistance

XType Flag
1 or Time
2 or Angle
6 or Step
8 or Position
9 or Temperature
10 or Constant
11 or Current
12 or Voltage

Axis Type
Time Axis
Angle Axis
Step Axis
The motion direction axis.
The temperature axis.
The constant axis.
The resistor is current dependent.
The resistor is voltage dependent.

Periodic Flag
0 or On
1 or Off

Flag for Periodic Iteration
Periodic Iteration
Non Periodic Iteration

InitialResistance Double

The initial resistance

reference Int

Reference component

terminal1 Int

Reference Probe 1

terminal2 Int

Reference Probe 2

TimeVsRes Table

The resistor vs time point array

StepVsRes Table

The resistor vs step point array

AngleVsRes Table

The resistor vs angle point array

DispVsRes Table

The resistor vs displacement point array

TempVsRes Table

The resistor vs temperature point array

CurrentVsRes Table

The current resistor point array

VoltageVsRes Table

The voltage resistor point array

TemperatureDependentType Flag
0 or PointArray
1 or TemperatureDependentCorrection

Resistance Setting Type
The point array type.
The temperature dependent correction type.

BaseTemperatureResistance Double

The base temperature resistance

BaseTemperature Double

The base temperature

TemperatureCoefficient Double

The temperature factor

IncludeResistanceLoss Flag
0 or Off
1 or On
Include resistance loss in circuit loss
Not including resistance loss in circuit loss.
Including resistance loss in circuit loss.