Properties Used for the Job Settings

The power simulation license (PSL) is paid license for multi-case calculations such as parametric analysis, optimizations, JMAG-RT, etc.
See the following page for details.
JMAG-Designer Help [Home > Licenses > JMAG Power Simulation Licenses]

Job(Job)

Description

Property
(propName)
Type
(Type)
Flag
(scriptKeyName)

Description

Queued Flag
0
1

Status flag of jobs
Wait
Submit queue

RestartStep Double

Number of steps for restarting a calculation(restart)

OutputStep Double

The first step to use for the output

RestartStage Double

Number of stages for restarting a calculation(restart)

Title String

Job title

FilePath String

Path to the JCF file used in a coupled analysis

Sub String

Path to the JCF file used in a coupled analysis

MapMin Double

The lower limit in the Z-axis direction for the loss generation region

MapMax Double

The upper limit in the Z-axis direction for the loss generation region

MapSectionPosition Double

The position of the section

MapSectionAngle Double

The angle in the circumferential direction centering the Y-axis with reference to the XY- plane

UseAvloss Flag
0 or Off
1 or ON

Running the average loss
Do not run
Run

Avloss Flag
0 or Off
1 or ON

Running the average loss
Do not run
Run

Mapping Flag
0 or Off
1 or ON

Use different mesh between each analysis
Do not use
Use

UseRange Flag
0 or Off
1 or ON

Specify the range to average loss
Do not specify
Specify

RangeType Flag
0 or step
1 or time

Specify the range for the averaging losses by type
step
time

Step Double

Final step for loss averaging range

Time Double

Final time for loss averaging range

SaveMesh Flag
0 or Off
1 or ON

Generate mesh only once (magnetic field analysis)
Do not generate
Generate

UseRotationAverage Flag
0 or Off
1 or ON

Use rotation average
Do not use
Use

MachineName String

Name of the machine to use for a calculation that is run remotely

CpuGroup String

Name of the CPU group to use for a calculation that is run remotely

KeepRemote Flag
0 or Off
1 or On
2 or Both

Keep the results on the management server when running calculations remotely
Deletes results
Keeps results
Keeps results on server and copies to local

ResubmitMachineName String

Name of the machine to use when resubmitting remote jobs

ResubmitCpuGroup String

Name of the CPU group to use when resubmitting remote jobs

SendSSHSettings Flag
0 or Off
1 or On

Send SSH settings to remote machine
Do not send SSH settings
Send SSH settings

LicenseLimits String

Set maximum number of license used

PBSQueue String

PBS queue parameter

PBSResource String

PBS resource parameter

LSFQueue String

LSF queue parameter

LSFOptions String

LSF options parameter

SlurmOptions String

Slurm options parameter

NumNodes Int

Number of nodes

CoresPerNode Int

Cores per node

UseJobSystem Flag
0 or Off
1 or On

Use the JMAG Job System
Do not use the job system
Use the job system

ResubmitJobs Flag
0 or Off
1 or On

Resubmit jobs on the remote machine
Do not resubmit jobs
Resubmit jobs

LicenseControl Flag
0 or Off
1 or On

Use the Job System's license control
Do not use license control
Use license control

HostsFile String

Host file (*.txt) path

UseStartTime Flag
0 or Off
1 or ON

Start time for applying
Do not set the start time
Set the start time

StartTime Double

The start time for the selected magnetic field analysis

UseEndTime Flag
0 or Off
1 or ON

End time for applying
Do not set the end time
Set the end time

EndTime Double

The end time for the selected magnetic field analysis

UseNumDivisions Flag
0 or Off
1 or ON

Divisions
Do not set the number of divisions
Set the number of divisions

NumDivisions Int

Number of divisions for an area from [Start time to apply] to [End time to apply]

SkipEndTime Flag
0 or Off
1 or ON

Skip End Time
Do not skip end time
Skip end time

AbaqusModule String

Abaqus modules

CouplingPort String

Coupling port

LengthUnit String
m
mm
in

Unit of length used in an input file for an external program
m
mm
in

LossDensityUnit String
W/m^3
W/mm^3
W/in^3

Unit of iron loss density used in an input file for an external program
W/m^3
W/mm^3
W/in^3

ForceUnit String
N
ldf

Unit of force used in an input file for an external program
N
ldf

ForceDensityUnit String
N/m^3
N/mm^3
lbf/in^3

Unit of force density used in an input file for an external program
N/m^3
N/mm^3
lbf/in^3

MapHeat Flag
0 or Off
1 or On

Mapping heat source
Do not create map
Create map

UseMagResult Flag
0 or Off
1 or On

Use magnetic field analysis results for mapping
Do not use
Use

MagScaleFactor Double

Scale factor applied to magnetic field analysis results

UseLossResult Flag
0 or Off
1 or ON

Use iron loss analysis result for a mapping
Do not use
Use

MapForce Flag
0 or Off
1 or On

Mapping electromagnetic force
Do not create map
Create map

ForceScaleFactor Double

Scale factor applied to electromagnetic force

ForceEnlargementDistance Double

Enlargement distance

MapTemperature Flag
0 or Off
1 or On

Mapping temperature
Do not create map
Create map

MapDisplacement Flag
0 or Off
1 or On

Mapping displacement
Do not create map
Create map

MapAverageTemperature Flag
0 or Off
1 or On

Mapping average temperature
Do not create map
Create map

RegionList String

Element set name to be mapped with physical amount from JMAG

CommandLine String

Abaqus Command Line Option

Position Double

The position of the section

SetRange Flag
0 or Off
1 or On

Specify the range to average loss
Do not specify
Specify

NumOfJobs Int

Num of jobs

CheckConflict Flag
0 or Off
1 or On

Perform the conflict check
Do not perform the conflict checkng
Perform the conflict check

IgnoreGeometryError Flag
0 or Off
1 or On

Ignore the geometry errors when running analysis
Do not ignore
Ignore

Optimization Flag
0 or False
1 or True

Run Optimization
Do not use the optimizer
Run the optimizer

TemperatureUnit String

Temperature unit

LossScaleFactor Double

Loss scale factor

TemperatureScaleFactor Double

Temperature scale factor

DisplacementScaleFactor Double

Displacement scale factor

AbaqusTime Flag
0 or Off
1 or On

Abaqus Time
not abaqus time
abaqus time

MinimumTime Double

Minimum Time

AbaqusExplicit Flag
0 or Off
1 or On

Abaqus Explicit
abaqus implicit
abaqus explicit

ErrCheck Flag
0 or false
1 or true

Error check
Do not use err check
Use err check

MultiLicense Flag
0 or Off
1 or ON

Multi-calculation license
Do not use the multi-calculation license
Use the multi-calculation license

ReservationKey String

License Reservation Key

CouplingType Flag 1 or CSE

Coupling Type

ForceMappingType Flag
0 or MapLorentzFoce
1 or MapNodalForce

Force Mapping Type
Map Lorentz Foce
Map Nodal Force

AbaqusLengthUnit String

Abaqus length unit

AbaqusMassUnit String

Abaqus mass unit

AbaqusTemperatureUnit String

Abaqus temperature unit

CreateMeshOnly Flag
0 or False
1 or True

The flag to create mesh only
Normal job
Create mesh job

PreProcessOnWrite Flag
0 or False
1 or True

The flag to preprocess the model on writing
Do not preprocess the model
Preprocess the model

RunMagAnalysisFirst Flag
0 or Off
1 or ON

Run magnetic field analysis first
Run structural analysis before magnetic field analysis
Run magnetic field analysis first

RunRangeFinderOnly Flag
0 or False
1 or True

Flag to run a Range Finder job
Normal job
Range finder job

DeleteScratch Flag
0 or Off
1 or On

Specifies whether or not to delete the local scratch directory
Do not delete files
Delete files

UseLocalCalculationFolder Flag
0 or Off
1 or On
Specifies whether or not to use local calculation folder
Do not use local calculation folder
Use local calculation folder