Study Properties for Thermal Stress Analysis


HSCommonNonDMP(HSCommonNonDMP)

HSCommonNonDMP properties

Property
(propName)
Type
(Type)
Flag
(scriptKeyName)

Description

UseMultiCPU Flag
0 or NonParallel
0 or Off
1 or SMP
1 or On

Flag for the use of multi cpu
Do not use multi cpu
Do not use multi cpu
Use SMP
Use SMP

MultiCPU Flag Degree of parallelism for SMP

Study Properties(HeatStressControl)

HeatStressControl properties

Property
(propName)
Type
(Type)
Flag
(scriptKeyName)

Description

IccgAccel Double

The value of acceleration coefficient

IccgTolerance Double

The value of convergence tolerance

IccgMaxIteration Flag

The value of max iteration

NonlinearMaxIteration Flag

The number of nonlinear iteration

NonlinearTolerance Double

The value of nonlinear iterative convergence tolerance

Coupling Flag
0 or Off
1 or On

The flag for coupling analysis
The coupling analysis is not executed.
The coupling analysis is executed.

UsrsubName String

The user subroutine name

UsrArraySize Flag

The size of users subroutine point array

Temperature Flag
0 or Off
1 or On

The flag for output temperature
Not output the temperature.
Output the temperature.

HeatFlux Flag
0 or Off
1 or On

The flag for output heat flux
Not output the heat flux.
Output the heat flux.

HeatGenerationDensity Flag
0 or Off
1 or On

The flag for output heat source density
Not output the heat source density.
Output the heat source density.

HeatTransferCoefficient Flag
0 or Off
1 or On

The flag for output heat transfer coefficient
Not output the heat transfer coefficient.
Output the heat transfer coefficient.

Stress Flag
0 or Off
1 or On

The flag for output stress
Not output the stress.
Output the stress.

Strain Flag
0 or Off
1 or On

The flag for output strain
Not output the strain.
Output the strain.

Force Flag
0 or Off
1 or On

The flag for output force
Not output the force.
Output the force.

SolverReportFile Flag
0 or Off
1 or On

The flag for output solver report file
Not output the solver report file.
Output the solver report file.

PartialModelConversion Flag
0 or Off
1 or On

The flag to treat as full model.
The input value is not converted as a partial model.
The input value is converted as a partial model.

ConversionFactor Double

Conversion factor excluding periodic boundary

OutputTimingSameStep Flag
0 or Off
1 or On

Flag to use same step by table and field results
Output another step by table and field results
Output same step by table and field results

TimeSteppingScheme Flag
0 or ImplicitMethod
1 or FullyImplicitMethod

The flag for implicit method type
Use implicit method.
Use fully implicit method

ThermalStressConvergenceTolerance Double

The nonlinear convergence tolerance

ThermalStressLoadControl Flag
0 or Manual
1 or Auto

The load control.
The manual control.
The automatic control.

ThermalStressMaxIterations Flag

The maximum number of non linear iterations

ThermalStressLoadIncrements Flag

The value of non linear load increments

ThermalStressTargetIterations Flag

The target iterations

ThermalStressUseModifiedNewtonRaphson Flag
0 or Off
1 or On

The flag of modified Newton-Raphson
Not using modified Newton-Raphson.
Use modified Newton-Raphson

ThermalStressModifiedNewtonRaphsonMaxIterations Flag

The maximum number of Newton-Raphson iterations

ThermalStressModifiedNewtonRaphsonConvergenceTolerance Double

The Newton-Raphson convergence tolerance

ThermalStressContactMethod Flag
0 or Penalty
1 or AugmentedLagrangian

The contact method.
The penalty contact method.
The augmented lagrangian method.

ThermalStressNormalAugmentation Flag
0 or Off
1 or On

The flag to augment normal contact force.
The normal contact force is not augmented.
The normal contact force is augmented.

ThermalStressTangentialAugmentation Flag
0 or Off
1 or On

The flag to augment tangential contact force.
The tangential contact force is not augmented.
The tangential contact force is augmented.

ThermalStressContactTolerance Double

The contact convergence tolerance

ThermalStressContactMaxIteration Flag

The maximum number of contact iterations

ThermalStressApplyAutoLoad Flag
0 or Off
1 or On

The flag to apply auto load
Do not apply auto load
Apply auto load

ThermalStressUseIterativePenaltyFactorAdjustment Flag
0 or OFF
1 or ON

The flag to use iterative penalty factor adjustment.
Don't use iterative penalty factor adjustment.
Use iterative penalty factor adjustment.

ThermalStressAutoLoadInitFactor Double

The initial factor of auto load-increment

ThermalStressAutoLoadRatio Double

The common ratio of auto load-increment

ThermalStressContactForce Flag
0 or Off
1 or On

The flag for output of contact force results
The contact force result won't be put into a result file
The contact force result will be put into a result file

ThermalStressContactPressure Flag
0 or Off
1 or On

The flag for output contact pressure result
Not output the contact pressure.
Output the contact pressure.

ThermalStressPlasticStrain Flag
0 or Off
1 or On

The flag for output of plastic strain results
The plastic strain result won't be put into a result file
The plastic strain result will be put into a result file

CsvOutputPath String

The output path for the csv files

CsvResultTypes String

The list of result types to output the csv files

CsvOutputResponseData Flag

CSV file output response value

CsvOutputInductanceData Flag

CSV file output efficiency map inductance values

CsvOutputProbe Flag

CSV file output probe value

CsvOutputSection Flag

CSV file output section graph value

CsvOutputCalculation Flag

CSV file output calculation value

CsvOutputObjectiveData Flag

CSV file output objective value

CsvComponentType Flag
0 or RealImaginary
1 or AmplitudePhase
2 or RMS

Flag of component output type
Output real and imaginary
Output amplitude and phase
Output rms

CsvDivisionType Flag
0 or Off
1 or On

Flag of divide CSV file output by specified number of cases
Do not divide
Divide CSV output

CsvDivisionCase Flag

Specified number of cases

OutputControlType Flag
0 or SpecifyOutputResultItems
1 or OutputTableOnly
2 or DeleteResultFiles

The output control type
Specify Result Items to be Output.
Output only table results.
Delete result files.

LogOutputLevel Flag
0 or Debug
1 or Information
2 or Warning
3 or Error
The log output level
Debug
Information
Warning
Error