MBD

Sort condition
Newest first
Oldest first
Large number of views
  1. [RTML-061] PMSM/IPM Constant rating 100(kW) 3-phase, Open-End Winding

    Type: PMSM | Max Power: 100(kW) | Stator(Outside Diameter): 250(mm) | Height: 259(mm) | Voltage/Current: DC350(V)/400(A) | Rotor: IPM

  2. [JAC295] Inverter Changeover Control for an Open-end Winding Motor

    This case study runs a circuit simulation of an open-end winding motor drive system that switches from using a single inverter to dual inverters during operation in order to mitig…

  3. [W-MB-181] Validation of JMAG-RT Spatial Harmonic Model Accuracy: Comparison of Differential Equation Models, Integral Method Models, and FEA

    JMAG-RT generates models that can simulate nonlinear motor characteristics for use in control circuit designs done with software-in-the-loop (SIL), hardware-in-the-loop (HIL), and…

  4. Enabling Full EDU Optimization and Losses Analysis Under Different PWM Strategies and DC Voltages Employing Combined JMAG-MATLAB Simulation Environments

    Nicola Rossi, Rimac Technology

  5. Applied Cases of EV Motor Controller Tuning by MILS using JMAG-RT

    Nobuo Morimura, SUBARU CORPORATION

  6. Model-Based Calibration Enables Optimal Torque Control of Synchronous Motors in a Short Time

    Atsushi Katagiri, MathWorks Japan

  7. SIMBA, Reinventing Motor Drive Simulation

    Ryoko Imamura, Powersys

  8. [JAC292] Evaluating Energy Consumption During Drive Cycle Using Loss Maps with Temperature Dependency for IPM Motors

    In this example, loss maps with temperature dependency for an IPM motor are used to compare and evaluate the energy consumption and efficiency during a WLTC drive cycle while usin…

  9. [RTML-060] IM Constant rating 100(kW)

    Type: IM | Max Power: 100(kW) | Stator(Outside Diameter): 200(mm) | Height: 65(mm) | Voltage/Current: DC500(V)/600(A) | Rotor/Mover: Cage

  10. [RTML-059] IM Constant rating 100(kW)

    Type: IM | Max Power: 100(kW) | Stator(Outside Diameter): 125(mm) | Height: 259(mm) | Voltage/Current: DC600(V)/400(A) | Rotor/Mover: Cage

  11. [RTML-058] IM Constant rating 10(kW)

    Type: IM | Max Power: 10(kW) | Stator(Outside Diameter): 92.5(mm) | Height: 37(mm) | Voltage/Current: DC440(V)/200(A) | Rotor/Mover: Cage

  12. [RTML-057] IM Constant rating 1(kW)

    Type: IM | Max Power: 1(kW) | Stator(Outside Diameter): 57.5(mm) | Height: 20(mm) | Voltage/Current: DC100(V)/28.3(A) | Rotor/Mover: Cage

  13. [RTML-056] WFSM_08

    Type: WFSM | Max Power: 75(kW) | Stator(Outside Diameter): 400(mm) | Height: 65(mm) | Voltage/Current: DC500(V)/283(A), DC600(V)/50(A) | Rotor/Mover: WF | Number of Phases: 3

  14. [RTML-055] WFSM_07

    Type: WFSM | Max Power: 75(kW) | Stator(Outside Diameter): 212(mm) | Height: 200(mm) | Voltage/Current: DC600(V)/250(A), DC600(V)/45(A) | Rotor/Mover: WF | Number of Phases: 3

  15. [RTML-054] WFSM_06

    Type: WFSM | Max Power: 75(kW) | Stator(Outside Diameter): 212(mm) | Height: 200(mm) | Voltage/Current: DC600(V)/250(A), DC200(V)/20(A) | Rotor/Mover: WF | Number of Phases: 3

  16. [RTML-053] WFSM_05

    Type: WFSM | Max Power: 10(kW) | Stator(Outside Diameter): 185(mm) | Height: 50(mm) | Voltage/Current: DC240(V)/84.8(A), DC300(V)/35(A) | Rotor/Mover: WF | Number of Phases: 3

Search Filter

  • All Categories

Remember me
Sign In
Create an account (Free) About authentication ID for JMAG website