Control2D properties
| Property (propName) | Type (Type) | Flag (scriptKeyName) | Description |
|---|---|---|---|
| FullModelConversion | Flag | 0 or Off 1 or On | Flag for Conversion to Value in Full Model |
| ConversionFactor | Double | Conversion factor excluding periodic boundary | |
| ModelThickness | Double | Thickness of the Model | |
| ManualCoilLength | Flag | 0 or Off 1 or On | Flag of Independent Length of the Coil from Thickness of the Model |
| CoilLength | Double | Length of the FEM Coil | |
| Coupling | Flag | 0 or Off 1 or On | Flag for Coupled Analysis |
| CoupledRemesh | Flag | 0 or Off 1 or On | The flag for coupled remesh region |
| ConversionType | Flag | 0 or NotUse 1 or Periodic 2 or SeriesParallel | The flag of circuit conversion type |
| CircuitConversionFactor | Double | The conversion factor of circuit | |
| CircuitConnect | Flag | 0 or Series 1 or Parallel 2 or AntiParallel | The circuit connect information |
| PowerCalcTolerance | Double | The power calculation tolerance | |
| PowerCalcInitialCurrent | Double | The power calculation initial current | |
| PowerCalcMaxIteration | Flag | The calculation max iteration | |
| Series | Double | The number of series | |
| Parallel | Double | The number of parallel | |
| ConnectionMode | Flag | 0 or ModifiedNodal 1 or ClosedLoop | Ths circuit analysis method |
| UseWindingFactor | Flag | 0 or Off 1 or On | The flag of use conversion factors from winding |
| UseForceCorrection | Flag | 0 or Off 1 or On | The Force Correction |
| SymmetryPlane1 | Coordinate | The symmetry plane 1 for the force correction | |
| CalculationMethod | Flag | 0 or Direct 2 or Iterative | Flag of Calculation Method Type |
| ApproximateTransientAnalysis | Flag | 0 or Off 1 or On | The flag for use steady-state approximate transient analysis |
| SpecifySlip | Flag | 0 or Off 1 or On | The flag for stationary device or induction motor |
| SteadyLinear | Flag | 0 or Nonlinear 1 or Linear | The flag to control non-linear type for pseudo steady state analysis. |
| Slip | Double | Slip value(s <= 1) | |
| OutputSteadyResultAs1stStep | Flag | 0 or Off 1 or On | The flag for output steady result as 1st step |
| SetPseudoSteadyStateFreq | Flag | 0 or Off 1 or On | The flag for setting pseudo-steady state frequency |
| PseudoSteadyStateFrequency | Double | pseudo steady-state frequency | |
| SetUseCorrectBHCurve | Flag | 0 or Off 1 or On | The flag for using correct bh curve for pseudo-steady state |
| TimePeriodicEEC | Flag | 0 or Off 1 or On | The flag for time periodic explicit error correction |
| TimePeriodicType | Flag | 1 or AntiPeriodic 2 or Periodic | The flag of time periodic type |
| ReversePeriodic | Flag | 0 or Off 1 or On | The flag reverse periodic rotor |
| UseRelaxation | Flag | 0 or Off 1 or On | The flag use non-linear relaxation |
| CorrectionType | Flag | 0 or frequency 1 or step | The flag for correction type |
| CorrectionFrequency | Double | Frequency of correction | |
| CorrectionInterval | Flag | Interval of correction step | |
| MaxCorrections | Flag | Max number of correction process | |
| FailureConvergenceError | Flag | 0 or Off 1 or On | The flag to handle the failure of convergence as an error |
| ShortenCorrectionInterval | Flag | 0 or Off 1 or On | The flag for shortening interval check |
| AllStepsTransientCalculation | Flag | 0 or Off 1 or On | The flag for calculate and output all steps of transient calculation |
| UseGPU | Flag | 0 or Off 1 or On | The flag for use GPU |
| RestartType | Flag | 0 or NotRestart 1 or FromTR 2 or FromFQ | The restart type |
| RestartSavFile | String | The sav file for restart | |
| RestartMsvFile | String | The msv file for restart | |
| RestartSvcFile | String | The svc file for restart | |
| DirectSolverType | Flag | 0 or ICCG 1 or Direct 2 or Auto | The flag of linear solver type |
| IccgAccel | Double | Value of Acceleration Coefficient | |
| AutoAccel | Flag | 0 or Off 1 or On | Flag to Set Acceleration Coefficient Automatically |
| ICCGToleranceType | Flag | 1 or Automatic 2 or Constant 4 or ScaleIndependent | Flag of ICCG Calculation Type |
| InitialTolerance | Double | Value of Initial Convergence Tolerance | |
| MinimumTolerance | Double | Value of Minimum Convergence Tolerance. | |
| IccgTolerance | Double | Value of Convergence Tolerance | |
| IccgLimit | Double | Value of Divergence Limit | |
| IccgMaxIteration | Flag | Value of Maximum Iteration | |
| IccgToleranceScaleIndependent | Double | The value of convergence tolerance.(Scale independent) | |
| IccgOptimumValue | Flag | 0 or Off 1 or On | Flag of Convergence Refinement |
| NonlinearMethod | Flag | 0 or Newton-Raphson 1 or SuccessiveIteration | Nonlinear Iterative Calculation Type |
| ConvergenceType | Flag | 0 or Solution 1 or ResidualVector 2 or MagneticFluxDensityAndCircuit 3 or SolutionExcludingCircuit 4 or ResidualVectorExcludingCircuit 5 or MagneticFluxDensity | Convergence determination type |
| RelaxationFactor | Flag | 0 or Off 1 or Type1 2 or Type2 5 or FactorAuto | Flag of Relaxation Factor Type |
| NonlinearMaxIteration | Flag | Number of Nonlinear Iteration | |
| NonlinearTolerance | Double | Value of Nonlinear Iterative Convergence Tolerance | |
| NonlinearConvergenceB | Flag | 0 or Off 1 or On | The maximum amount of change flag of the magnetic flux density |
| NonlinearConvergenceV | Flag | 0 or Off 1 or On | The maximum amount of change flag of the voltage |
| NonlinearConvergenceI | Flag | 0 or Off 1 or On | The maximum amount of change flag of the current |
| NonlinearConvergenceToleranceB | Double | The maximum amount of change in the magnetic flux density | |
| NonlinearConvergenceToleranceV | Double | The maximum amount of change in the voltage | |
| NonlinearConvergenceToleranceI | Double | The maximum amount of change in the current | |
| NonlinearStrictConvergence | Flag | 0 or Off 0 or Off 1 or On 1 or On | Flag of Strict Judgment of Nonlinear Iterative Calculation |
| NonlinearSpeedup | Flag | 0 or Off 1 or On | Flag of Using Nonlinear Speeding-up Function |
| BHCorrection | Flag | 0 or Off 1 or On | Flag for applying a correction to the BH curve for frequency response analysis. |
| MagneticFluxDensity | Flag | 0 or Off 1 or On | The flag for output magnetic flux density result |
| Magnetization | Flag | 0 or Off 1 or On | The flag for output magnetization |
| PermeanceFactor | Flag | 0 or Off 1 or On | The flag for output permeance factor |
| Permeability | Flag | 0 or Off 1 or On | The flag for output permeability |
| DifferentialPermeability | Flag | 0 or Off 1 or On | The flag for output differential permeability |
| CurrentDensity | Flag | 0 or Off 1 or On | The flag for output current density result |
| LossDensity | Flag | 0 or Off 1 or On | The flag for output loss density |
| Displacement | Flag | 0 or Off 1 or On | The flag for output nodal displacement result |
| NodalForce | Flag | 0 or Off 1 or On | The flag for output nodal force result |
| SurfaceForceDensity | Flag | 0 or Off 1 or On | The flag for surface force density |
| LorentzForceDensity | Flag | 0 or Off 1 or On | The flag for output Lorentz force density |
| VectorPotential | Flag | 0 or Off 1 or On | The flag for output vector potential |
| Energy | Flag | 0 or Off 1 or On | The flag for output energy result |
| Stress | Flag | 0 or Off 1 or On | The flag for output stress result |
| DemagnetizationRatio | Flag | 0 or Off 1 or On | The flag for output demagnetization ratio (Compared to reference step) |
| DemagnetizationRatioDiffUnDemag | Flag | 0 or Off 1 or On | The flag for output demagnetization ratio (Compared to undemagnetized state) |
| HysteresisLossDensity | Flag | 0 or Off 1 or On | The flag for output hysteresis loss density |
| RestartFile | Flag | 0 or Off 1 or On | The flag for output restart file |
| RestartFileOutputInterval | Flag | The minimum output interval(minute) for restart file | |
| JCGMonitor | Flag | 0 or Off 1 or On | The flag for output ICCG Iteration Count Monitoring file. |
| SolverReportFile | Flag | 0 or Off 1 or On | The flag for output solver report file |
| InitialMagnetization | Flag | 0 or Off 1 or On | The flag for initial magnetization |
| CoerciveForceNormal | Flag | 0 or Off 1 or On | The flag to control output of normalized Coercive Force |
| MagnetizationRatio | Flag | 0 or Off 1 or On | The flag to control output of magnetization ratio |
| Temperature | Flag | 0 or Off 1 or On | The flag for output temperature |
| IronLossDensity | Flag | 0 or Off 1 or On | The flag for output iron loss density |
| ElectricField | Flag | 0 or Off 1 or On | The flag for output electric field result |
| MagneticFluxDensityLamination | Flag | 0 or Off 1 or On | The flag to output lamination magnetic flux density |
| MagneticFieldStrengthLamination | Flag | 0 or Off 1 or On | The flag to output lamination magnetic field strength |
| EddyCurrentDensityLamination | Flag | 0 or Off 1 or On | The flag to output lamination eddy current density |
| CurrentLossDensityLamination | Flag | 0 or Off 1 or On | The flag to output lamination current loss density |
| HysteresisLossDensityLamination | Flag | 0 or Off 1 or On | The flag to output lamination hysteresis loss density |
| CriticalCurrentDensity | Flag | 0 or Off 1 or On | The flag to output critical current density |
| IronRefMagneticFluxDensity | Flag | 0 or Off 1 or On | The flag for output reference magnetic flux density result (Iron) |
| IronIronLossDensity | Flag | 0 or Off 1 or On | The flag for output iron loss density (Iron) |
| IronHysteresisLossDensity | Flag | 0 or Off 1 or On | The flag for output hysteresis loss density (Iron) |
| IronExcessEddyCurrentDensity | Flag | 0 or Off 1 or On | The flag for output excess eddy current loss density (Iron) |
| IronClassicalEddyCurrentDensity | Flag | 0 or Off 1 or On | The flag for output classical eddy current loss density (Iron) |
| IronJouleLossDensity | Flag | 0 or Off 1 or On | The flag for output Joule loss density (Iron) |
| IronStress | Flag | 0 or Off 1 or On | The flag for output stress result (Iron) |
| IronMagneticFluxDensityLamination | Flag | 0 or Off 1 or On | The flag to output lamination magnetic flux density (Iron) |
| IronMagneticFieldStrengthLamination | Flag | 0 or Off 1 or On | The flag to output lamination magnetic field strength (Iron) |
| IronEddyCurrentDensityLamination | Flag | 0 or Off 1 or On | The flag to output lamination eddy current density (Iron) |
| IronCurrentLossDensityLamination | Flag | 0 or Off 1 or On | The flag to output lamination current loss density (Iron) |
| IronHysteresisLossDensityLamination | Flag | 0 or Off 1 or On | The flag to output lamination hysteresis loss density (Iron) |
| OutputTimingMode | Flag | 0 or Off 1 or FromStep 1 or On 2 or SpecifyInterval | A flag to control timing of output to plot file |
| OutputStartStep | Flag | The first step to use for the output | |
| MinimizeResults | Flag | 0 or Off 1 or On | Flag to control minimization of output results |
| OutputIntervalTable | Table | output control interval table | |
| OutputTimingSameStep | Flag | 0 or Off 1 or On | Flag to use same step by table and field results |
| OutputResultsTimingMode | Flag | 0 or Off 1 or FromStep 1 or On 2 or SpecifyInterval 3 or NoOutput | Flag to control step output to result file |
| OutputResultsStartStep | Flag | The first step to use for the output | |
| OutputResultsIntervalTable | Table | output control interval table | |
| Hsusr1 | Flag | 0 or Off 1 or On | Flag of User Subroutine "hsusr1" |
| Hsusr3 | Flag | 0 or Off 1 or On | Flag of User Subroutine "hsusr3" |
| Hsusr4 | Flag | 0 or Off 1 or On | Flag of User Subroutine "hsusr4" |
| Usrfle | Flag | 0 or Off 1 or On | Flag of User Subroutine "usrfle" |
| Usrstp | Flag | 0 or Off 1 or On | Flag of User Subroutine "usrstp" |
| Usrlos | Flag | 0 or Off 1 or On | Flag of User Subroutine "usrlos" |
| Usrhys | Flag | 0 or Off 1 or On | Flag of User Subroutine "usrhys" |
| Usrfm2 | Flag | 0 or Off 1 or On | Flag of User Subroutine "usrfm2" |
| Usrfma | Flag | 0 or Off 1 or On 2 or usrfm3 | The flag of user subroutine "usrfma" |
| Usrstr | Flag | 0 or Off 1 or On | The flag of user subroutine "usrstr" |
| UsrArraySize | Flag | The size of users subroutine point array | |
| UsrsubName | String | User Subroutine Name | |
| Snapshot | Flag | 0 or Off 1 or On | The flag for Snapshot |
| Retry | Flag | Number of retries | |
| Divisions | Flag | Number of steps divided | |
| Monitor | Flag | 0 or Off 1 or On | The flag to output monitoring file during analysis execution |
| CsvOutputPath | String | The output path for the csv files | |
| CsvResultTypes | String | The list of result types to output the csv files | |
| CsvOutputResponseData | Flag | CSV file output response value | |
| CsvOutputInductanceData | Flag | CSV file output efficiency map inductance values | |
| CsvOutputProbe | Flag | CSV file output probe value | |
| CsvOutputSection | Flag | CSV file output section graph value | |
| CsvOutputCalculation | Flag | CSV file output calculation value | |
| CsvOutputObjectiveData | Flag | CSV file output objective value | |
| CsvComponentType | Flag | 0 or RealImaginary 1 or AmplitudePhase 2 or RMS | Flag of component output type |
| CsvDivisionType | Flag | 0 or Off 1 or On | Flag of divide CSV file output by specified number of cases |
| CsvDivisionCase | Flag | Specified number of cases | |
| OutputControlType | Flag | 0 or SpecifyOutputResultItems 1 or OutputTableOnly 2 or DeleteResultFiles | The output control type |
| LogOutputLevel | Flag | 0 or Debug 1 or Information 2 or Warning 3 or Error | The log output level Debug Information Warning Error |
| Property (propName) | Type (Type) | Flag (scriptKeyName) | Description |
|---|---|---|---|
| SteadyStateStopCheckMethod | Flag | 0 or Maximum 1 or Instantaneous 2 or Average 3 or Frequency | The stop method used for the steady state |
| SteadyStatePeriodic | Double | The Periodic used to determine steady state | |
| SteadyStateFrequency | Double | The frequency used to determine steady state | |
| HarmonicOrder | Flag | Harmonic Order | |
| SteadyStateThreshold | Double | The threshold used for the steady state | |
| SteadyStatePhaseThreshold | Double | The phase threshold used for the steady state | |
| UsePhaseStationary | Flag | 0 or Off 1 or On | Use phase stationary |
| SteadyStateReferenceResultSource | Flag | 1 or Torque 2 or Force 3 or FEMCoil 4 or FEMConductor 5 or CurrentCondition 6 or FluxCondition 7 or MotionDisplacement 8 or MotionSpeed 9 or Loss 10 or Voltage 11 or Current 12 or ControlSignal 13 or Temperature | The type of result used for the steady state |
| SteadyStateVoltageProbe | Int | Voltage probe for steady state | |
| SteadyStateCircuitCurrent | Int | Circuit component for current for steady state | |
| SteadyStateControleProbe | Int | Control probe for steady state | |
| SteadyStateTemperatureProbe | Int | Temperature probe for steady state | |
| SteadyStateResultComponent | Flag | 0 or Absolute 1 or First 2 or Second 3 or Third | The component of the result used for the steady state |
| SteadyStateLinkedTorque | Int | Linked torque condition for steady state | |
| SteadyStateLinkedForce | Int | Linked force condition for steady state | |
| SteadyStateLinkedCoil | Int | Linked FEM Coil for steady state | |
| SteadyStateLinkedConductor | Int | Linked FEM Conductor for steady state | |
| SteadyStateLinkedCurrent | Int | Linked current condition for steady state | |
| SteadyStateLinkedFlux | Int | Linked flux condition for steady state | |
| SteadyStateLinkedDisplacement | Int | Linked motion displacement for steady state | |
| SteadyStateLinkedSpeed | Int | Linked motion speed for steady state |
Control properties
| Property (propName) | Type (Type) | Flag (scriptKeyName) | Description |
|---|---|---|---|
| FullModelConversion | Flag | 0 or Off 1 or On | Flag for Conversion to Value in Full Model |
| ConversionFactor | Double | Conversion factor excluding periodic boundary | |
| Coupling | Flag | 0 or Off 1 or On | Flag for Coupled Analysis |
| CoupledRemesh | Flag | 0 or Off 1 or On | The flag for coupled remesh region |
| ConversionType | Flag | 0 or NotUse 1 or Periodic 2 or SeriesParallel | The flag of circuit conversion type |
| CircuitConversionFactor | Double | The conversion factor of circuit | |
| CircuitConnect | Flag | 0 or Series 1 or Parallel 2 or AntiParallel | The circuit connect information |
| PowerCalcTolerance | Double | The power calculation tolerance | |
| PowerCalcInitialCurrent | Double | The power calculation initial current | |
| PowerCalcMaxIteration | Flag | The calculation max iteration | |
| Series | Double | The number of series | |
| Parallel | Double | The number of parallel | |
| ConnectionMode | Flag | 0 or ModifiedNodal 1 or ClosedLoop | Ths circuit analysis method |
| UseWindingFactor | Flag | 0 or Off 1 or On | The flag of use conversion factors from winding |
| UseForceCorrection | Flag | 0 or Off 1 or On | The Force Correction |
| SymmetryPlane1 | Coordinate | The symmetry plane 1 for the force correction | |
| SymmetryPlane2 | Coordinate | The symmetry plane 2 for the force correction | |
| ApproximateTransientAnalysis | Flag | 0 or Off 1 or On | The flag for use steady-state approximate transient analysis |
| SpecifySlip | Flag | 0 or Off 1 or On | The flag for stationary device or induction motor |
| SteadyLinear | Flag | 0 or Nonlinear 1 or Linear | The flag to control non-linear type for pseudo steady state analysis. |
| Slip | Double | Slip value(s <= 1) | |
| OutputSteadyResultAs1stStep | Flag | 0 or Off 1 or On | The flag for output steady result as 1st step |
| SetPseudoSteadyStateFreq | Flag | 0 or Off 1 or On | The flag for setting pseudo-steady state frequency |
| PseudoSteadyStateFrequency | Double | pseudo steady-state frequency | |
| SetUseCorrectBHCurve | Flag | 0 or Off 1 or On | The flag for using correct bh curve for pseudo-steady state |
| TimePeriodicEEC | Flag | 0 or Off 1 or On | The flag for time periodic explicit error correction |
| TimePeriodicType | Flag | 1 or AntiPeriodic 2 or Periodic | The flag of time periodic type |
| ReversePeriodic | Flag | 0 or Off 1 or On | The flag reverse periodic rotor |
| UseRelaxation | Flag | 0 or Off 1 or On | The flag use non-linear relaxation |
| CorrectionType | Flag | 0 or frequency 1 or step | The flag for correction type |
| CorrectionFrequency | Double | Frequency of correction | |
| CorrectionInterval | Flag | Interval of correction step | |
| MaxCorrections | Flag | Max number of correction process | |
| FailureConvergenceError | Flag | 0 or Off 1 or On | The flag to handle the failure of convergence as an error |
| CalculateDisplacementCurrentInAir | Flag | 0 or Off 1 or On | The flag to control calculation of displacement currents in air regions |
| ShortenCorrectionInterval | Flag | 0 or Off 1 or On | The flag for shortening interval check |
| AllStepsTransientCalculation | Flag | 0 or Off 1 or On | The flag for calculate and output all steps of transient calculation |
| UseGPU | Flag | 0 or Off 1 or On | The flag for use GPU |
| RestartType | Flag | 0 or NotRestart 1 or FromTR 2 or FromFQ | The restart type |
| RestartSavFile | String | The sav file for restart | |
| RestartMsvFile | String | The msv file for restart | |
| RestartSvcFile | String | The svc file for restart | |
| DirectSolverType | Flag | 0 or ICCG 1 or Direct | The flag of linear solver type |
| IccgAccel | Double | Value of Acceleration Coefficient | |
| AutoAccel | Flag | 0 or Off 1 or On | Flag to Set Acceleration Coefficient Automatically |
| ICCGToleranceType | Flag | 1 or Automatic 2 or Constant 4 or ScaleIndependent | Flag of ICCG Calculation Type |
| InitialTolerance | Double | Value of Initial Convergence Tolerance | |
| MinimumTolerance | Double | Value of Minimum Convergence Tolerance. | |
| IccgTolerance | Double | Value of Convergence Tolerance | |
| IccgLimit | Double | Value of Divergence Limit | |
| IccgMaxIteration | Flag | Value of Maximum Iteration | |
| IccgToleranceScaleIndependent | Double | The value of convergence tolerance.(Scale independent) | |
| IccgOptimumValue | Flag | 0 or Off 1 or On | Flag of Convergence Refinement |
| APhiMethod | Flag | 0 or Off 1 or Method1 1 or On 2 or Method2 | Flag of Using A-Phi Method for Calculation |
| NonlinearMethod | Flag | 0 or Newton-Raphson 1 or SuccessiveIteration | Nonlinear Iterative Calculation Type |
| ConvergenceType | Flag | 0 or Solution 1 or ResidualVector 2 or MagneticFluxDensityAndCircuit 3 or SolutionExcludingCircuit 4 or ResidualVectorExcludingCircuit 5 or MagneticFluxDensity | Convergence determination type |
| RelaxationFactor | Flag | 0 or Off 1 or Type1 2 or Type2 5 or FactorAuto | Flag of Relaxation Factor Type |
| NonlinearMaxIteration | Flag | Number of Nonlinear Iteration | |
| NonlinearTolerance | Double | Value of Nonlinear Iterative Convergence Tolerance | |
| NonlinearConvergenceB | Flag | 0 or Off 1 or On | The maximum amount of change flag of the magnetic flux density |
| NonlinearConvergenceV | Flag | 0 or Off 1 or On | The maximum amount of change flag of the voltage |
| NonlinearConvergenceI | Flag | 0 or Off 1 or On | The maximum amount of change flag of the current |
| NonlinearConvergenceToleranceB | Double | The maximum amount of change in the magnetic flux density | |
| NonlinearConvergenceToleranceV | Double | The maximum amount of change in the voltage | |
| NonlinearConvergenceToleranceI | Double | The maximum amount of change in the current | |
| NonlinearStrictConvergence | Flag | 0 or Off 0 or Off 1 or On 1 or On | Flag of Strict Judgment of Nonlinear Iterative Calculation |
| NonlinearSpeedup | Flag | 0 or Off 1 or On | Flag of Using Nonlinear Speeding-up Function |
| BHCorrection | Flag | 0 or Off 1 or On | Flag for applying a correction to the BH curve for frequency response analysis. |
| MagneticFluxDensity | Flag | 0 or Off 1 or On | The flag for output magnetic flux density result |
| Magnetization | Flag | 0 or Off 1 or On | The flag for output magnetization |
| PermeanceFactor | Flag | 0 or Off 1 or On | The flag for output permeance factor |
| Permeability | Flag | 0 or Off 1 or On | The flag for output permeability |
| DifferentialPermeability | Flag | 0 or Off 1 or On | The flag for output differential permeability |
| CurrentDensity | Flag | 0 or Off 1 or On | The flag for output current density result |
| LossDensity | Flag | 0 or Off 1 or On | The flag for output loss density |
| Displacement | Flag | 0 or Off 1 or On | The flag for output nodal displacement result |
| NodalForce | Flag | 0 or Off 1 or On | The flag for output nodal force result |
| SurfaceForceDensity | Flag | 0 or Off 1 or On | The flag for surface force density |
| LorentzForceDensity | Flag | 0 or Off 1 or On | The flag for output Lorentz force density |
| VectorPotential | Flag | 0 or Off 1 or On | The flag for output vector potential |
| Energy | Flag | 0 or Off 1 or On | The flag for output energy result |
| Stress | Flag | 0 or Off 1 or On | The flag for output stress result |
| DemagnetizationRatio | Flag | 0 or Off 1 or On | The flag for output demagnetization ratio (Compared to reference step) |
| DemagnetizationRatioDiffUnDemag | Flag | 0 or Off 1 or On | The flag for output demagnetization ratio (Compared to undemagnetized state) |
| HysteresisLossDensity | Flag | 0 or Off 1 or On | The flag for output hysteresis loss density |
| RestartFile | Flag | 0 or Off 1 or On | The flag for output restart file |
| RestartFileOutputInterval | Flag | The minimum output interval(minute) for restart file | |
| JCGMonitor | Flag | 0 or Off 1 or On | The flag for output ICCG Iteration Count Monitoring file. |
| SolverReportFile | Flag | 0 or Off 1 or On | The flag for output solver report file |
| InitialMagnetization | Flag | 0 or Off 1 or On | The flag for initial magnetization |
| CoerciveForceNormal | Flag | 0 or Off 1 or On | The flag to control output of normalized Coercive Force |
| MagnetizationRatio | Flag | 0 or Off 1 or On | The flag to control output of magnetization ratio |
| Temperature | Flag | 0 or Off 1 or On | The flag for output temperature |
| IronLossDensity | Flag | 0 or Off 1 or On | The flag for output iron loss density |
| ElectricField | Flag | 0 or Off 1 or On | The flag for output electric field result |
| MagneticFluxDensityLamination | Flag | 0 or Off 1 or On | The flag to output lamination magnetic flux density |
| MagneticFieldStrengthLamination | Flag | 0 or Off 1 or On | The flag to output lamination magnetic field strength |
| EddyCurrentDensityLamination | Flag | 0 or Off 1 or On | The flag to output lamination eddy current density |
| CurrentLossDensityLamination | Flag | 0 or Off 1 or On | The flag to output lamination current loss density |
| HysteresisLossDensityLamination | Flag | 0 or Off 1 or On | The flag to output lamination hysteresis loss density |
| CriticalCurrentDensity | Flag | 0 or Off 1 or On | The flag to output critical current density |
| IronRefMagneticFluxDensity | Flag | 0 or Off 1 or On | The flag for output reference magnetic flux density result (Iron) |
| IronIronLossDensity | Flag | 0 or Off 1 or On | The flag for output iron loss density (Iron) |
| IronHysteresisLossDensity | Flag | 0 or Off 1 or On | The flag for output hysteresis loss density (Iron) |
| IronExcessEddyCurrentDensity | Flag | 0 or Off 1 or On | The flag for output excess eddy current loss density (Iron) |
| IronClassicalEddyCurrentDensity | Flag | 0 or Off 1 or On | The flag for output classical eddy current loss density (Iron) |
| IronJouleLossDensity | Flag | 0 or Off 1 or On | The flag for output Joule loss density (Iron) |
| IronStress | Flag | 0 or Off 1 or On | The flag for output stress result (Iron) |
| IronMagneticFluxDensityLamination | Flag | 0 or Off 1 or On | The flag to output lamination magnetic flux density (Iron) |
| IronMagneticFieldStrengthLamination | Flag | 0 or Off 1 or On | The flag to output lamination magnetic field strength (Iron) |
| IronEddyCurrentDensityLamination | Flag | 0 or Off 1 or On | The flag to output lamination eddy current density (Iron) |
| IronCurrentLossDensityLamination | Flag | 0 or Off 1 or On | The flag to output lamination current loss density (Iron) |
| IronHysteresisLossDensityLamination | Flag | 0 or Off 1 or On | The flag to output lamination hysteresis loss density (Iron) |
| OutputTimingMode | Flag | 0 or Off 1 or FromStep 1 or On 2 or SpecifyInterval | A flag to control timing of output to plot file |
| OutputStartStep | Flag | The first step to use for the output | |
| MinimizeResults | Flag | 0 or Off 1 or On | Flag to control minimization of output results |
| OutputIntervalTable | Table | output control interval table | |
| OutputTimingSameStep | Flag | 0 or Off 1 or On | Flag to use same step by table and field results |
| OutputResultsTimingMode | Flag | 0 or Off 1 or FromStep 1 or On 2 or SpecifyInterval 3 or NoOutput | Flag to control step output to result file |
| OutputResultsStartStep | Flag | The first step to use for the output | |
| OutputResultsIntervalTable | Table | output control interval table | |
| Hsusr1 | Flag | 0 or Off 1 or On | Flag of User Subroutine "hsusr1" |
| Hsusr3 | Flag | 0 or Off 1 or On | Flag of User Subroutine "hsusr3" |
| Hsusr4 | Flag | 0 or Off 1 or On | Flag of User Subroutine "hsusr4" |
| Usrfle | Flag | 0 or Off 1 or On | Flag of User Subroutine "usrfle" |
| Usrstp | Flag | 0 or Off 1 or On | Flag of User Subroutine "usrstp" |
| Usrlos | Flag | 0 or Off 1 or On | Flag of User Subroutine "usrlos" |
| Usrhys | Flag | 0 or Off 1 or On | Flag of User Subroutine "usrhys" |
| Usrfm2 | Flag | 0 or Off 1 or On | Flag of User Subroutine "usrfm2" |
| Usrfma | Flag | 0 or Off 1 or On 2 or usrfm3 | The flag of user subroutine "usrfma" |
| Usrstr | Flag | 0 or Off 1 or On | The flag of user subroutine "usrstr" |
| UsrArraySize | Flag | The size of users subroutine point array | |
| UsrsubName | String | User Subroutine Name | |
| Snapshot | Flag | 0 or Off 1 or On | The flag for Snapshot |
| Retry | Flag | Number of retries | |
| Divisions | Flag | Number of steps divided | |
| Monitor | Flag | 0 or Off 1 or On | The flag to output monitoring file during analysis execution |
| CsvOutputPath | String | The output path for the csv files | |
| CsvResultTypes | String | The list of result types to output the csv files | |
| CsvOutputResponseData | Flag | CSV file output response value | |
| CsvOutputInductanceData | Flag | CSV file output efficiency map inductance values | |
| CsvOutputProbe | Flag | CSV file output probe value | |
| CsvOutputSection | Flag | CSV file output section graph value | |
| CsvOutputCalculation | Flag | CSV file output calculation value | |
| CsvOutputObjectiveData | Flag | CSV file output objective value | |
| CsvComponentType | Flag | 0 or RealImaginary 1 or AmplitudePhase 2 or RMS | Flag of component output type |
| CsvDivisionType | Flag | 0 or Off 1 or On | Flag of divide CSV file output by specified number of cases |
| CsvDivisionCase | Flag | Specified number of cases | |
| OutputControlType | Flag | 0 or SpecifyOutputResultItems 1 or OutputTableOnly 2 or DeleteResultFiles | The output control type |
| LogOutputLevel | Flag | 0 or Debug 1 or Information 2 or Warning 3 or Error | The log output level Debug Information Warning Error |
TransformerMagControl properties
| Property (propName) | Type (Type) | Flag (scriptKeyName) | Description |
|---|---|---|---|
| FullModelConversion | Flag | 0 or Off 1 or On | Flag for Conversion to Value in Full Model |
| ConversionFactor | Double | Conversion factor excluding periodic boundary | |
| Coupling | Flag | 0 or Off 1 or On | Flag for Coupled Analysis |
| CoupledRemesh | Flag | 0 or Off 1 or On | The flag for coupled remesh region |
| ConversionType | Flag | 0 or NotUse 1 or Periodic 2 or SeriesParallel | The flag of circuit conversion type |
| CircuitConversionFactor | Double | The conversion factor of circuit | |
| CircuitConnect | Flag | 0 or Series 1 or Parallel 2 or AntiParallel | The circuit connect information |
| PowerCalcTolerance | Double | The power calculation tolerance | |
| PowerCalcInitialCurrent | Double | The power calculation initial current | |
| PowerCalcMaxIteration | Flag | The calculation max iteration | |
| Series | Double | The number of series | |
| Parallel | Double | The number of parallel | |
| ConnectionMode | Flag | 0 or ModifiedNodal 1 or ClosedLoop | Ths circuit analysis method |
| UseWindingFactor | Flag | 0 or Off 1 or On | The flag of use conversion factors from winding |
| UseForceCorrection | Flag | 0 or Off 1 or On | The Force Correction |
| SymmetryPlane1 | Coordinate | The symmetry plane 1 for the force correction | |
| SymmetryPlane2 | Coordinate | The symmetry plane 2 for the force correction | |
| ApproximateTransientAnalysis | Flag | 0 or Off 1 or On | The flag for use steady-state approximate transient analysis |
| SpecifySlip | Flag | 0 or Off 1 or On | The flag for stationary device or induction motor |
| SteadyLinear | Flag | 0 or Nonlinear 1 or Linear | The flag to control non-linear type for pseudo steady state analysis. |
| Slip | Double | Slip value(s <= 1) | |
| OutputSteadyResultAs1stStep | Flag | 0 or Off 1 or On | The flag for output steady result as 1st step |
| SetPseudoSteadyStateFreq | Flag | 0 or Off 1 or On | The flag for setting pseudo-steady state frequency |
| PseudoSteadyStateFrequency | Double | pseudo steady-state frequency | |
| SetUseCorrectBHCurve | Flag | 0 or Off 1 or On | The flag for using correct bh curve for pseudo-steady state |
| TimePeriodicEEC | Flag | 0 or Off 1 or On | The flag for time periodic explicit error correction |
| TimePeriodicType | Flag | 1 or AntiPeriodic 2 or Periodic | The flag of time periodic type |
| ReversePeriodic | Flag | 0 or Off 1 or On | The flag reverse periodic rotor |
| UseRelaxation | Flag | 0 or Off 1 or On | The flag use non-linear relaxation |
| CorrectionType | Flag | 0 or frequency 1 or step | The flag for correction type |
| CorrectionFrequency | Double | Frequency of correction | |
| CorrectionInterval | Flag | Interval of correction step | |
| MaxCorrections | Flag | Max number of correction process | |
| FailureConvergenceError | Flag | 0 or Off 1 or On | The flag to handle the failure of convergence as an error |
| CalculateDisplacementCurrentInAir | Flag | 0 or Off 1 or On | The flag to control calculation of displacement currents in air regions |
| ShortenCorrectionInterval | Flag | 0 or Off 1 or On | The flag for shortening interval check |
| AllStepsTransientCalculation | Flag | 0 or Off 1 or On | The flag for calculate and output all steps of transient calculation |
| UseGPU | Flag | 0 or Off 1 or On | The flag for use GPU |
| RestartType | Flag | 0 or NotRestart 1 or FromTR 2 or FromFQ | The restart type |
| RestartSavFile | String | The sav file for restart | |
| RestartMsvFile | String | The msv file for restart | |
| RestartSvcFile | String | The svc file for restart | |
| DirectSolverType | Flag | 0 or ICCG 1 or Direct | The flag of linear solver type |
| IccgAccel | Double | Value of Acceleration Coefficient | |
| AutoAccel | Flag | 0 or Off 1 or On | Flag to Set Acceleration Coefficient Automatically |
| ICCGToleranceType | Flag | 1 or Automatic 2 or Constant 4 or ScaleIndependent | Flag of ICCG Calculation Type |
| InitialTolerance | Double | Value of Initial Convergence Tolerance | |
| MinimumTolerance | Double | Value of Minimum Convergence Tolerance. | |
| IccgTolerance | Double | Value of Convergence Tolerance | |
| IccgLimit | Double | Value of Divergence Limit | |
| IccgMaxIteration | Flag | Value of Maximum Iteration | |
| IccgToleranceScaleIndependent | Double | The value of convergence tolerance.(Scale independent) | |
| IccgOptimumValue | Flag | 0 or Off 1 or On | Flag of Convergence Refinement |
| APhiMethod | Flag | 0 or Off 1 or Method1 1 or On 2 or Method2 | Flag of Using A-Phi Method for Calculation |
| NonlinearMethod | Flag | 0 or Newton-Raphson 1 or SuccessiveIteration | Nonlinear Iterative Calculation Type |
| ConvergenceType | Flag | 0 or Solution 1 or ResidualVector 2 or MagneticFluxDensityAndCircuit 3 or SolutionExcludingCircuit 4 or ResidualVectorExcludingCircuit 5 or MagneticFluxDensity | Convergence determination type |
| RelaxationFactor | Flag | 0 or Off 1 or Type1 2 or Type2 5 or FactorAuto | Flag of Relaxation Factor Type |
| NonlinearMaxIteration | Flag | Number of Nonlinear Iteration | |
| NonlinearTolerance | Double | Value of Nonlinear Iterative Convergence Tolerance | |
| NonlinearConvergenceB | Flag | 0 or Off 1 or On | The maximum amount of change flag of the magnetic flux density |
| NonlinearConvergenceV | Flag | 0 or Off 1 or On | The maximum amount of change flag of the voltage |
| NonlinearConvergenceI | Flag | 0 or Off 1 or On | The maximum amount of change flag of the current |
| NonlinearConvergenceToleranceB | Double | The maximum amount of change in the magnetic flux density | |
| NonlinearConvergenceToleranceV | Double | The maximum amount of change in the voltage | |
| NonlinearConvergenceToleranceI | Double | The maximum amount of change in the current | |
| NonlinearStrictConvergence | Flag | 0 or Off 0 or Off 1 or On 1 or On | Flag of Strict Judgment of Nonlinear Iterative Calculation |
| NonlinearSpeedup | Flag | 0 or Off 1 or On | Flag of Using Nonlinear Speeding-up Function |
| BHCorrection | Flag | 0 or Off 1 or On | Flag for applying a correction to the BH curve for frequency response analysis. |
| MagneticFluxDensity | Flag | 0 or Off 1 or On | The flag for output magnetic flux density result |
| Magnetization | Flag | 0 or Off 1 or On | The flag for output magnetization |
| PermeanceFactor | Flag | 0 or Off 1 or On | The flag for output permeance factor |
| Permeability | Flag | 0 or Off 1 or On | The flag for output permeability |
| DifferentialPermeability | Flag | 0 or Off 1 or On | The flag for output differential permeability |
| CurrentDensity | Flag | 0 or Off 1 or On | The flag for output current density result |
| LossDensity | Flag | 0 or Off 1 or On | The flag for output loss density |
| Displacement | Flag | 0 or Off 1 or On | The flag for output nodal displacement result |
| NodalForce | Flag | 0 or Off 1 or On | The flag for output nodal force result |
| SurfaceForceDensity | Flag | 0 or Off 1 or On | The flag for surface force density |
| LorentzForceDensity | Flag | 0 or Off 1 or On | The flag for output Lorentz force density |
| VectorPotential | Flag | 0 or Off 1 or On | The flag for output vector potential |
| Energy | Flag | 0 or Off 1 or On | The flag for output energy result |
| Stress | Flag | 0 or Off 1 or On | The flag for output stress result |
| DemagnetizationRatio | Flag | 0 or Off 1 or On | The flag for output demagnetization ratio (Compared to reference step) |
| DemagnetizationRatioDiffUnDemag | Flag | 0 or Off 1 or On | The flag for output demagnetization ratio (Compared to undemagnetized state) |
| HysteresisLossDensity | Flag | 0 or Off 1 or On | The flag for output hysteresis loss density |
| RestartFile | Flag | 0 or Off 1 or On | The flag for output restart file |
| RestartFileOutputInterval | Flag | The minimum output interval(minute) for restart file | |
| JCGMonitor | Flag | 0 or Off 1 or On | The flag for output ICCG Iteration Count Monitoring file. |
| SolverReportFile | Flag | 0 or Off 1 or On | The flag for output solver report file |
| InitialMagnetization | Flag | 0 or Off 1 or On | The flag for initial magnetization |
| CoerciveForceNormal | Flag | 0 or Off 1 or On | The flag to control output of normalized Coercive Force |
| MagnetizationRatio | Flag | 0 or Off 1 or On | The flag to control output of magnetization ratio |
| Temperature | Flag | 0 or Off 1 or On | The flag for output temperature |
| IronLossDensity | Flag | 0 or Off 1 or On | The flag for output iron loss density |
| ElectricField | Flag | 0 or Off 1 or On | The flag for output electric field result |
| MagneticFluxDensityLamination | Flag | 0 or Off 1 or On | The flag to output lamination magnetic flux density |
| MagneticFieldStrengthLamination | Flag | 0 or Off 1 or On | The flag to output lamination magnetic field strength |
| EddyCurrentDensityLamination | Flag | 0 or Off 1 or On | The flag to output lamination eddy current density |
| CurrentLossDensityLamination | Flag | 0 or Off 1 or On | The flag to output lamination current loss density |
| HysteresisLossDensityLamination | Flag | 0 or Off 1 or On | The flag to output lamination hysteresis loss density |
| CriticalCurrentDensity | Flag | 0 or Off 1 or On | The flag to output critical current density |
| IronRefMagneticFluxDensity | Flag | 0 or Off 1 or On | The flag for output reference magnetic flux density result (Iron) |
| IronIronLossDensity | Flag | 0 or Off 1 or On | The flag for output iron loss density (Iron) |
| IronHysteresisLossDensity | Flag | 0 or Off 1 or On | The flag for output hysteresis loss density (Iron) |
| IronExcessEddyCurrentDensity | Flag | 0 or Off 1 or On | The flag for output excess eddy current loss density (Iron) |
| IronClassicalEddyCurrentDensity | Flag | 0 or Off 1 or On | The flag for output classical eddy current loss density (Iron) |
| IronJouleLossDensity | Flag | 0 or Off 1 or On | The flag for output Joule loss density (Iron) |
| IronStress | Flag | 0 or Off 1 or On | The flag for output stress result (Iron) |
| IronMagneticFluxDensityLamination | Flag | 0 or Off 1 or On | The flag to output lamination magnetic flux density (Iron) |
| IronMagneticFieldStrengthLamination | Flag | 0 or Off 1 or On | The flag to output lamination magnetic field strength (Iron) |
| IronEddyCurrentDensityLamination | Flag | 0 or Off 1 or On | The flag to output lamination eddy current density (Iron) |
| IronCurrentLossDensityLamination | Flag | 0 or Off 1 or On | The flag to output lamination current loss density (Iron) |
| IronHysteresisLossDensityLamination | Flag | 0 or Off 1 or On | The flag to output lamination hysteresis loss density (Iron) |
| OutputTimingMode | Flag | 0 or Off 1 or FromStep 1 or On 2 or SpecifyInterval | A flag to control timing of output to plot file |
| OutputStartStep | Flag | The first step to use for the output | |
| MinimizeResults | Flag | 0 or Off 1 or On | Flag to control minimization of output results |
| OutputIntervalTable | Table | output control interval table | |
| OutputTimingSameStep | Flag | 0 or Off 1 or On | Flag to use same step by table and field results |
| OutputResultsTimingMode | Flag | 0 or Off 1 or FromStep 1 or On 2 or SpecifyInterval 3 or NoOutput | Flag to control step output to result file |
| OutputResultsStartStep | Flag | The first step to use for the output | |
| OutputResultsIntervalTable | Table | output control interval table | |
| Hsusr1 | Flag | 0 or Off 1 or On | Flag of User Subroutine "hsusr1" |
| Hsusr3 | Flag | 0 or Off 1 or On | Flag of User Subroutine "hsusr3" |
| Hsusr4 | Flag | 0 or Off 1 or On | Flag of User Subroutine "hsusr4" |
| Usrfle | Flag | 0 or Off 1 or On | Flag of User Subroutine "usrfle" |
| Usrstp | Flag | 0 or Off 1 or On | Flag of User Subroutine "usrstp" |
| Usrlos | Flag | 0 or Off 1 or On | Flag of User Subroutine "usrlos" |
| Usrhys | Flag | 0 or Off 1 or On | Flag of User Subroutine "usrhys" |
| Usrfm2 | Flag | 0 or Off 1 or On | Flag of User Subroutine "usrfm2" |
| Usrfma | Flag | 0 or Off 1 or On 2 or usrfm3 | The flag of user subroutine "usrfma" |
| Usrstr | Flag | 0 or Off 1 or On | The flag of user subroutine "usrstr" |
| UsrArraySize | Flag | The size of users subroutine point array | |
| UsrsubName | String | User Subroutine Name | |
| Snapshot | Flag | 0 or Off 1 or On | The flag for Snapshot |
| Retry | Flag | Number of retries | |
| Divisions | Flag | Number of steps divided | |
| Monitor | Flag | 0 or Off 1 or On | The flag to output monitoring file during analysis execution |
| CsvOutputPath | String | The output path for the csv files | |
| CsvResultTypes | String | The list of result types to output the csv files | |
| CsvOutputResponseData | Flag | CSV file output response value | |
| CsvOutputInductanceData | Flag | CSV file output efficiency map inductance values | |
| CsvOutputProbe | Flag | CSV file output probe value | |
| CsvOutputSection | Flag | CSV file output section graph value | |
| CsvOutputCalculation | Flag | CSV file output calculation value | |
| CsvOutputObjectiveData | Flag | CSV file output objective value | |
| CsvComponentType | Flag | 0 or RealImaginary 1 or AmplitudePhase 2 or RMS | Flag of component output type |
| CsvDivisionType | Flag | 0 or Off 1 or On | Flag of divide CSV file output by specified number of cases |
| CsvDivisionCase | Flag | Specified number of cases | |
| OutputControlType | Flag | 0 or SpecifyOutputResultItems 2 or DeleteResultFiles | The output control type |
| LogOutputLevel | Flag | 0 or Debug 1 or Information 2 or Warning 3 or Error | The log output level Debug Information Warning Error |
TransformerControl properties
| Property (propName) | Type (Type) | Flag (scriptKeyName) | Description |
|---|---|---|---|
| FlgMode3dSt | Flag | 0 or Off 1 or On | Flag run as 3D ST mode |
| AnalysisType | Flag | 0 or Stack 1 or Cylindrical | Analysis type |
| FlgUse3dCorrection | Flag | 0 or Off 1 or On | Flag use 3D correction |
| FlgUseCoreThicknessCorrection | Flag | 0 or Off 1 or On | Use correction of model thickness |
| CoreThickness | Double | Model Thickness | |
| FlgUseFqAnalysis | Flag | 0 or Off 1 or On | Flag use FQ analysis FQ analysis does not be used. FQ Analysis is used. |
Common properties
| Property (propName) | Type (Type) | Flag (scriptKeyName) | Description |
|---|---|---|---|
| UseMultiCPU | Flag | 0 or NonParallel 0 or Off 1 or SMP 1 or On 2 or MPP 2 or DMP | Flag for the use of multi cpu |
| MultiCPU | Flag | Degree of parallelism for SMP | |
| MppCPU | Flag | MPP process parallelism | |
| MppThread | Flag | MPP thread parallelism | |
| IronLossMode | Flag | 0 or Off 1 or On | The mode of calculation of iron loss conditions |
| ParallelComputing | Flag | 0 or Off 1 or On | The flag of use parallel computing for iron loss conditions Not use parallel computing for loss conditions Use parallel computing for loss conditions |
| Property (propName) | Type (Type) | Flag (scriptKeyName) | Description |
|---|---|---|---|
| Step | Flag | The number of analysis steps | |
| TimeStep | Double | The value of time step | |
| StepType | Flag | 0 or Simple 1 or Uniform 2 or Time | The step type: simple = 0, uniform = 1, time = 2 |
| StepDivision | Flag | The division of steps | |
| EndPoint | Double | The value of end point | |
| Nonlinear | Table | The nonlinear vs time point array | |
| MaximumTime | Double | Value of Maximum Progress | |
| Angle | Double | The value of movement angle | |
| Distance | Double | Value of Movement Distance | |
| Division | Table | Time vs Division Table | |
| FirstEndTime | Double | The end time of the first period | |
| FirstDivision | Flag | The number of divisions of the first period | |
| SecondEndTime | Double | The end time of the second period | |
| SecondDivision | Flag | The number of divisions of the second period | |
| StopOnSteadyState | Flag | 0 or Off 1 or On | Stop the analysis when steady state is reached. Do not stop Stop analysis on steady state |
| Property (propName) | Type (Type) | Flag (scriptKeyName) | Description |
|---|---|---|---|
| Step | Flag | The number of analysis steps | |
| StepType | Flag | 0 or Simple 1 or Uniform 2 or Frequency 3 or Section 4 or Time | The step type: simple = 0 , uniform = 1 , frequency = 2 , section = 3 , time = 4 |
| FrequencyStep | Double | The value of frequency step | |
| Initialfrequency | Double | The initial frequency | |
| StartPoint | Double | The value of start point | |
| EndPoint | Double | The value of end point | |
| StepDivision | Flag | The division of steps | |
| Nonlinear | Table | The nonlinear vs frequency point array | |
| Division | Table | The frequency vs division point array | |
| TimeVsFrequency | Table | The frequency vs time point array |
ControlCircuit properties
| Property (propName) | Type (Type) | Flag (scriptKeyName) | Description |
|---|---|---|---|
| FullModelConversion | Flag | 0 or Off 1 or On | Flag for Conversion to Value in Full Model |
| ConversionFactor | Double | Conversion factor excluding periodic boundary | |
| ModelThickness | Double | Thickness of the Model | |
| ManualCoilLength | Flag | 0 or Off 1 or On | Flag of Independent Length of the Coil from Thickness of the Model |
| CoilLength | Double | Length of the FEM Coil | |
| Coupling | Flag | 0 or Off 1 or On | Flag for Coupled Analysis |
| CoupledRemesh | Flag | 0 or Off 1 or On | The flag for coupled remesh region |
| ConversionType | Flag | 0 or NotUse 2 or SeriesParallel | The flag of circuit conversion type |
| CircuitConversionFactor | Double | The conversion factor of circuit | |
| CircuitConnect | Flag | 0 or Series 1 or Parallel 2 or AntiParallel | The circuit connect information |
| PowerCalcTolerance | Double | The power calculation tolerance | |
| PowerCalcInitialCurrent | Double | The power calculation initial current | |
| PowerCalcMaxIteration | Flag | The calculation max iteration | |
| Series | Double | The number of series | |
| Parallel | Double | The number of parallel | |
| ConnectionMode | Flag | 0 or ModifiedNodal 1 or ClosedLoop | Ths circuit analysis method |
| UseWindingFactor | Flag | 0 or Off 1 or On | The flag of use conversion factors from winding |
| UseForceCorrection | Flag | 0 or Off 1 or On | The Force Correction |
| SymmetryPlane1 | Coordinate | The symmetry plane 1 for the force correction | |
| CalculationMethod | Flag | 0 or Direct 2 or Iterative | Flag of Calculation Method Type |
| ApproximateTransientAnalysis | Flag | 0 or Off 1 or On | The flag for use steady-state approximate transient analysis |
| SpecifySlip | Flag | 0 or Off 1 or On | The flag for stationary device or induction motor |
| SteadyLinear | Flag | 0 or Nonlinear 1 or Linear | The flag to control non-linear type for pseudo steady state analysis. |
| Slip | Double | Slip value(s <= 1) | |
| OutputSteadyResultAs1stStep | Flag | 0 or Off 1 or On | The flag for output steady result as 1st step |
| SetPseudoSteadyStateFreq | Flag | 0 or Off 1 or On | The flag for setting pseudo-steady state frequency |
| PseudoSteadyStateFrequency | Double | pseudo steady-state frequency | |
| SetUseCorrectBHCurve | Flag | 0 or Off 1 or On | The flag for using correct bh curve for pseudo-steady state |
| TimePeriodicEEC | Flag | 0 or Off 1 or On | The flag for time periodic explicit error correction |
| TimePeriodicType | Flag | 1 or AntiPeriodic 2 or Periodic | The flag of time periodic type |
| ReversePeriodic | Flag | 0 or Off 1 or On | The flag reverse periodic rotor |
| UseRelaxation | Flag | 0 or Off 1 or On | The flag use non-linear relaxation |
| CorrectionType | Flag | 0 or frequency 1 or step | The flag for correction type |
| CorrectionFrequency | Double | Frequency of correction | |
| CorrectionInterval | Flag | Interval of correction step | |
| MaxCorrections | Flag | Max number of correction process | |
| FailureConvergenceError | Flag | 0 or Off 1 or On | The flag to handle the failure of convergence as an error |
| ShortenCorrectionInterval | Flag | 0 or Off 1 or On | The flag for shortening interval check |
| AllStepsTransientCalculation | Flag | 0 or Off 1 or On | The flag for calculate and output all steps of transient calculation |
| UseGPU | Flag | 0 or Off 1 or On | The flag for use GPU |
| RestartType | Flag | 0 or NotRestart 1 or FromTR | The restart type |
| RestartSavFile | String | The sav file for restart | |
| RestartMsvFile | String | The msv file for restart | |
| RestartSvcFile | String | The svc file for restart | |
| DirectSolverType | Flag | 0 or ICCG 1 or Direct 2 or Auto | The flag of linear solver type |
| IccgAccel | Double | Value of Acceleration Coefficient | |
| AutoAccel | Flag | 0 or Off 1 or On | Flag to Set Acceleration Coefficient Automatically |
| ICCGToleranceType | Flag | 1 or Automatic 2 or Constant 4 or ScaleIndependent | Flag of ICCG Calculation Type |
| InitialTolerance | Double | Value of Initial Convergence Tolerance | |
| MinimumTolerance | Double | Value of Minimum Convergence Tolerance. | |
| IccgTolerance | Double | Value of Convergence Tolerance | |
| IccgLimit | Double | Value of Divergence Limit | |
| IccgMaxIteration | Flag | Value of Maximum Iteration | |
| IccgToleranceScaleIndependent | Double | The value of convergence tolerance.(Scale independent) | |
| IccgOptimumValue | Flag | 0 or Off 1 or On | Flag of Convergence Refinement |
| NonlinearMethod | Flag | 0 or Newton-Raphson 1 or SuccessiveIteration | Nonlinear Iterative Calculation Type |
| ConvergenceType | Flag | 0 or Solution 1 or ResidualVector 2 or MagneticFluxDensityAndCircuit 3 or SolutionExcludingCircuit 4 or ResidualVectorExcludingCircuit 5 or MagneticFluxDensity | Convergence determination type |
| RelaxationFactor | Flag | 0 or Off 1 or Type1 2 or Type2 5 or FactorAuto | Flag of Relaxation Factor Type |
| NonlinearMaxIteration | Flag | Number of Nonlinear Iteration | |
| NonlinearTolerance | Double | Value of Nonlinear Iterative Convergence Tolerance | |
| NonlinearConvergenceB | Flag | 0 or Off 1 or On | The maximum amount of change flag of the magnetic flux density |
| NonlinearConvergenceV | Flag | 0 or Off 1 or On | The maximum amount of change flag of the voltage |
| NonlinearConvergenceI | Flag | 0 or Off 1 or On | The maximum amount of change flag of the current |
| NonlinearConvergenceToleranceB | Double | The maximum amount of change in the magnetic flux density | |
| NonlinearConvergenceToleranceV | Double | The maximum amount of change in the voltage | |
| NonlinearConvergenceToleranceI | Double | The maximum amount of change in the current | |
| NonlinearStrictConvergence | Flag | 0 or Off 0 or Off 1 or On 1 or On | Flag of Strict Judgment of Nonlinear Iterative Calculation |
| NonlinearSpeedup | Flag | 0 or Off 1 or On | Flag of Using Nonlinear Speeding-up Function |
| BHCorrection | Flag | 0 or Off 1 or On | Flag for applying a correction to the BH curve for frequency response analysis. |
| MagneticFluxDensity | Flag | 0 or Off 1 or On | The flag for output magnetic flux density result |
| Magnetization | Flag | 0 or Off 1 or On | The flag for output magnetization |
| PermeanceFactor | Flag | 0 or Off 1 or On | The flag for output permeance factor |
| Permeability | Flag | 0 or Off 1 or On | The flag for output permeability |
| DifferentialPermeability | Flag | 0 or Off 1 or On | The flag for output differential permeability |
| CurrentDensity | Flag | 0 or Off 1 or On | The flag for output current density result |
| LossDensity | Flag | 0 or Off 1 or On | The flag for output loss density |
| Displacement | Flag | 0 or Off 1 or On | The flag for output nodal displacement result |
| NodalForce | Flag | 0 or Off 1 or On | The flag for output nodal force result |
| SurfaceForceDensity | Flag | 0 or Off 1 or On | The flag for surface force density |
| LorentzForceDensity | Flag | 0 or Off 1 or On | The flag for output Lorentz force density |
| VectorPotential | Flag | 0 or Off 1 or On | The flag for output vector potential |
| Energy | Flag | 0 or Off 1 or On | The flag for output energy result |
| Stress | Flag | 0 or Off 1 or On | The flag for output stress result |
| DemagnetizationRatio | Flag | 0 or Off 1 or On | The flag for output demagnetization ratio (Compared to reference step) |
| DemagnetizationRatioDiffUnDemag | Flag | 0 or Off 1 or On | The flag for output demagnetization ratio (Compared to undemagnetized state) |
| HysteresisLossDensity | Flag | 0 or Off 1 or On | The flag for output hysteresis loss density |
| RestartFile | Flag | 0 or Off 1 or On | The flag for output restart file |
| RestartFileOutputInterval | Flag | The minimum output interval(minute) for restart file | |
| SolverReportFile | Flag | 0 or Off 1 or On | The flag for output solver report file |
| InitialMagnetization | Flag | 0 or Off 1 or On | The flag for initial magnetization |
| CoerciveForceNormal | Flag | 0 or Off 1 or On | The flag to control output of normalized Coercive Force |
| MagnetizationRatio | Flag | 0 or Off 1 or On | The flag to control output of magnetization ratio |
| Temperature | Flag | 0 or Off 1 or On | The flag for output temperature |
| IronLossDensity | Flag | 0 or Off 1 or On | The flag for output iron loss density |
| ElectricField | Flag | 0 or Off 1 or On | The flag for output electric field result |
| MagneticFluxDensityLamination | Flag | 0 or Off 1 or On | The flag to output lamination magnetic flux density |
| MagneticFieldStrengthLamination | Flag | 0 or Off 1 or On | The flag to output lamination magnetic field strength |
| EddyCurrentDensityLamination | Flag | 0 or Off 1 or On | The flag to output lamination eddy current density |
| CurrentLossDensityLamination | Flag | 0 or Off 1 or On | The flag to output lamination current loss density |
| HysteresisLossDensityLamination | Flag | 0 or Off 1 or On | The flag to output lamination hysteresis loss density |
| CriticalCurrentDensity | Flag | 0 or Off 1 or On | The flag to output critical current density |
| IronRefMagneticFluxDensity | Flag | 0 or Off 1 or On | The flag for output reference magnetic flux density result (Iron) |
| IronIronLossDensity | Flag | 0 or Off 1 or On | The flag for output iron loss density (Iron) |
| IronHysteresisLossDensity | Flag | 0 or Off 1 or On | The flag for output hysteresis loss density (Iron) |
| IronExcessEddyCurrentDensity | Flag | 0 or Off 1 or On | The flag for output excess eddy current loss density (Iron) |
| IronClassicalEddyCurrentDensity | Flag | 0 or Off 1 or On | The flag for output classical eddy current loss density (Iron) |
| IronJouleLossDensity | Flag | 0 or Off 1 or On | The flag for output Joule loss density (Iron) |
| IronStress | Flag | 0 or Off 1 or On | The flag for output stress result (Iron) |
| IronMagneticFluxDensityLamination | Flag | 0 or Off 1 or On | The flag to output lamination magnetic flux density (Iron) |
| IronMagneticFieldStrengthLamination | Flag | 0 or Off 1 or On | The flag to output lamination magnetic field strength (Iron) |
| IronEddyCurrentDensityLamination | Flag | 0 or Off 1 or On | The flag to output lamination eddy current density (Iron) |
| IronCurrentLossDensityLamination | Flag | 0 or Off 1 or On | The flag to output lamination current loss density (Iron) |
| IronHysteresisLossDensityLamination | Flag | 0 or Off 1 or On | The flag to output lamination hysteresis loss density (Iron) |
| OutputTimingMode | Flag | 0 or Off 1 or FromStep 1 or On 2 or SpecifyInterval | A flag to control timing of output to plot file |
| OutputStartStep | Flag | The first step to use for the output | |
| MinimizeResults | Flag | 0 or Off 1 or On | Flag to control minimization of output results |
| OutputIntervalTable | Table | output control interval table | |
| OutputTimingSameStep | Flag | 0 or Off 1 or On | Flag to use same step by table and field results |
| OutputResultsTimingMode | Flag | 0 or Off 1 or FromStep 1 or On 2 or SpecifyInterval 3 or NoOutput | Flag to control step output to result file |
| OutputResultsStartStep | Flag | The first step to use for the output | |
| OutputResultsIntervalTable | Table | output control interval table | |
| Hsusr1 | Flag | 0 or Off 1 or On | Flag of User Subroutine "hsusr1" |
| Hsusr3 | Flag | 0 or Off 1 or On | Flag of User Subroutine "hsusr3" |
| Hsusr4 | Flag | 0 or Off 1 or On | Flag of User Subroutine "hsusr4" |
| Usrfle | Flag | 0 or Off 1 or On | Flag of User Subroutine "usrfle" |
| Usrstp | Flag | 0 or Off 1 or On | Flag of User Subroutine "usrstp" |
| Usrlos | Flag | 0 or Off 1 or On | Flag of User Subroutine "usrlos" |
| Usrhys | Flag | 0 or Off 1 or On | Flag of User Subroutine "usrhys" |
| Usrfm2 | Flag | 0 or Off 1 or On | Flag of User Subroutine "usrfm2" |
| Usrfma | Flag | 0 or Off 1 or On 2 or usrfm3 | The flag of user subroutine "usrfma" |
| Usrstr | Flag | 0 or Off 1 or On | The flag of user subroutine "usrstr" |
| UsrArraySize | Flag | The size of users subroutine point array | |
| UsrsubName | String | User Subroutine Name | |
| Snapshot | Flag | 0 or Off 1 or On | The flag for Snapshot |
| Retry | Flag | Number of retries | |
| Divisions | Flag | Number of steps divided | |
| Monitor | Flag | 0 or Off 1 or On | The flag to output monitoring file during analysis execution |
| CsvOutputPath | String | The output path for the csv files | |
| CsvResultTypes | String | The list of result types to output the csv files | |
| CsvOutputResponseData | Flag | CSV file output response value | |
| CsvOutputInductanceData | Flag | CSV file output efficiency map inductance values | |
| CsvOutputProbe | Flag | CSV file output probe value | |
| CsvOutputSection | Flag | CSV file output section graph value | |
| CsvOutputCalculation | Flag | CSV file output calculation value | |
| CsvOutputObjectiveData | Flag | CSV file output objective value | |
| CsvComponentType | Flag | 0 or RealImaginary 1 or AmplitudePhase 2 or RMS | Flag of component output type |
| CsvDivisionType | Flag | 0 or Off 1 or On | Flag of divide CSV file output by specified number of cases |
| CsvDivisionCase | Flag | Specified number of cases | |
| OutputControlType | Flag | 0 or SpecifyOutputResultItems 2 or DeleteResultFiles | The output control type |
| LogOutputLevel | Flag | 0 or Debug 1 or Information 2 or Warning 3 or Error | The log output level Debug Information Warning Error |