Settings Specified in the Magnetic Field Analysis Study and Transformer Analysis Study


Study Properties(Control2D)

Control2D properties

Property
(propName)
Type
(Type)
Flag
(scriptKeyName)

Description

FullModelConversion Flag
0 or Off
1 or On

Flag for Conversion to Value in Full Model
The result is not converted as a full model.
The result is converted as a full model.

ConversionFactor Double

Conversion factor excluding periodic boundary

ModelThickness Double

Thickness of the Model

ManualCoilLength Flag
0 or Off
1 or On

Flag of Independent Length of the Coil from Thickness of the Model
The length of FEM coil is independent from the thickness of the model.
The length of FEM coil is equal to the thickness of the model.

CoilLength Double

Length of the FEM Coil

Coupling Flag
0 or Off
1 or On

Flag for Coupled Analysis
Do not run the Coupled Analysis.
Run the coupled analysis.

CoupledRemesh Flag
0 or Off
1 or On

The flag for coupled remesh region
The region is not coupled remesh.
The air region is coupled remesh.

ConversionType Flag
0 or NotUse
1 or Periodic
2 or SeriesParallel

The flag of circuit conversion type
The circuit conversion is not used.
The periodic conversion type
The circuit conversion type for series/parallel

CircuitConversionFactor Double

The conversion factor of circuit

CircuitConnect Flag
0 or Series
1 or Parallel
2 or AntiParallel

The circuit connect information
The series type
The parallel type
The anti parallel type

PowerCalcTolerance Double

The power calculation tolerance

PowerCalcInitialCurrent Double

The power calculation initial current

PowerCalcMaxIteration Flag

The calculation max iteration

Series Double

The number of series

Parallel Double

The number of parallel

ConnectionMode Flag
0 or ModifiedNodal
1 or ClosedLoop

Ths circuit analysis method
The modified nodal analysis type
The closed loop current analysis type

UseWindingFactor Flag
0 or Off
1 or On

The flag of use conversion factors from winding
Set conversion factors manually
Set conversion factors from winding

UseForceCorrection Flag
0 or Off
1 or On

The Force Correction
The force correction is not used.
The force correction is used.

SymmetryPlane1 Coordinate

The symmetry plane 1 for the force correction

CalculationMethod Flag
0 or Direct
2 or Iterative

Flag of Calculation Method Type
Use FEM+BEM calculation method.
Use FEM calculation method.

ApproximateTransientAnalysis Flag
0 or Off
1 or On

The flag for use steady-state approximate transient analysis
Do not use steady-state approximate transient analysis
Use steady-state approximate transient analysis

SpecifySlip Flag
0 or Off
1 or On

The flag for stationary device or induction motor
Set as stationary device.
User can specify slip as induction motor.

SteadyLinear Flag
0 or Nonlinear
1 or Linear

The flag to control non-linear type for pseudo steady state analysis.
Use conventional method of quasi steady state analysis.
Use fast acceleration of quasi-steady state analysis.

Slip Double

Slip value(s <= 1)

OutputSteadyResultAs1stStep Flag
0 or Off
1 or On

The flag for output steady result as 1st step
Do not output steady result as 1st step
Output steady result as 1st step

SetPseudoSteadyStateFreq Flag
0 or Off
1 or On

The flag for setting pseudo-steady state frequency
Do not use frequency for pseudo steady-state
Use frequency for pseudo steady-state

PseudoSteadyStateFrequency Double

pseudo steady-state frequency

SetUseCorrectBHCurve Flag
0 or Off
1 or On

The flag for using correct bh curve for pseudo-steady state
Do not use correct bh curve for pseudo steady-state
Use correct bh curve for pseudo steady-state

TimePeriodicEEC Flag
0 or Off
1 or On

The flag for time periodic explicit error correction
The time periodic explicit error correction is not executed.
The time periodic explicit error correction is executed.

TimePeriodicType Flag
1 or AntiPeriodic
2 or Periodic

The flag of time periodic type
Anti-Periodic
Periodic

ReversePeriodic Flag
0 or Off
1 or On

The flag reverse periodic rotor
The reverse periodic rotor is not used.
The reverse periodic rotor is used.

UseRelaxation Flag
0 or Off
1 or On

The flag use non-linear relaxation
Non-linear relaxation is not used
Use non-linear relaxation.

CorrectionType Flag
0 or frequency
1 or step

The flag for correction type
The correction type is frequency.
The correction type is step.

CorrectionFrequency Double

Frequency of correction

CorrectionInterval Flag

Interval of correction step

MaxCorrections Flag

Max number of correction process

FailureConvergenceError Flag
0 or Off
1 or On

The flag to handle the failure of convergence as an error
Warning.
Error(Solver will terminate).

ShortenCorrectionInterval Flag
0 or Off
1 or On

The flag for shortening interval check
Do usual interval check.
Shorten interval check.

AllStepsTransientCalculation Flag
0 or Off
1 or On

The flag for calculate and output all steps of transient calculation
Do not calculate and output all steps of transient calculation.
Calculate and output all steps of transient calculation.

UseGPU Flag
0 or Off
1 or On

The flag for use GPU
Not use GPU.
Use GPU.

RestartType Flag
0 or NotRestart
1 or FromTR
2 or FromFQ

The restart type
Do not use restart.
Restart from transient analysis
Restart from frequency analysis

RestartSavFile String

The sav file for restart

RestartMsvFile String

The msv file for restart

RestartSvcFile String

The svc file for restart

DirectSolverType Flag
0 or ICCG
1 or Direct
2 or Auto

The flag of linear solver type
ICCG
Direct solver
Auto

IccgAccel Double

Value of Acceleration Coefficient

AutoAccel Flag
0 or Off
1 or On

Flag to Set Acceleration Coefficient Automatically
The acceleration coefficient is set in manual.
The acceleration coefficient is automatically set.

ICCGToleranceType Flag
1 or Automatic
2 or Constant
4 or ScaleIndependent

Flag of ICCG Calculation Type
The ICCG tolerance is scaled using the original matrix right hand side vector. The tolerance is then adjusted automatically at each iteration.
The same ICCG tolerance is used for all NR iterations and is scaled using the original matrix right hand side vector.
The ICCG tolerance is scaled by the residual independently for each matrix solution.

InitialTolerance Double

Value of Initial Convergence Tolerance

MinimumTolerance Double

Value of Minimum Convergence Tolerance.

IccgTolerance Double

Value of Convergence Tolerance

IccgLimit Double

Value of Divergence Limit

IccgMaxIteration Flag

Value of Maximum Iteration

IccgToleranceScaleIndependent Double

The value of convergence tolerance.(Scale independent)

IccgOptimumValue Flag
0 or Off
1 or On

Flag of Convergence Refinement
No Refinement
Optimum Refinement

NonlinearMethod Flag
0 or Newton-Raphson
1 or SuccessiveIteration

Nonlinear Iterative Calculation Type
Newton-Raphson
Successive Iteration

ConvergenceType Flag
0 or Solution
1 or ResidualVector
2 or MagneticFluxDensityAndCircuit
3 or SolutionExcludingCircuit
4 or ResidualVectorExcludingCircuit
5 or MagneticFluxDensity

Convergence determination type
Using Variation of Solution
Using Magnitude of Residual Vector
Using Variation of Magnetic Flux Density and Circuit Variables
Using Variation of Solution (Excluding Circuit Variables)
Using Magnitude of Residual Vector (Excluding Circuit Variables)
Using Variation of Magnetic Flux Density

RelaxationFactor Flag
0 or Off
1 or Type1
2 or Type2
5 or FactorAuto

Flag of Relaxation Factor Type
No Relaxation
Relaxation Type 1
The relaxation type2
The relaxation auto

NonlinearMaxIteration Flag

Number of Nonlinear Iteration

NonlinearTolerance Double

Value of Nonlinear Iterative Convergence Tolerance

NonlinearConvergenceB Flag
0 or Off
1 or On

The maximum amount of change flag of the magnetic flux density
Not set the maximum amount of change in the magnetic flux density
To set the maximum amount of change in the magnetic flux density

NonlinearConvergenceV Flag
0 or Off
1 or On

The maximum amount of change flag of the voltage
Not set the maximum amount of change in the voltage
To set the maximum amount of change in the voltage

NonlinearConvergenceI Flag
0 or Off
1 or On

The maximum amount of change flag of the current
Not set the maximum amount of change in the current
To set the maximum amount of change in the current

NonlinearConvergenceToleranceB Double

The maximum amount of change in the magnetic flux density

NonlinearConvergenceToleranceV Double

The maximum amount of change in the voltage

NonlinearConvergenceToleranceI Double

The maximum amount of change in the current

NonlinearStrictConvergence Flag
0 or Off
0 or Off
1 or On
1 or On

Flag of Strict Judgment of Nonlinear Iterative Calculation
Normal judgment for convergence of nonlinear
Normal judgment for convergence of nonlinear
Strict judgment for convergence of nonlinear
Strict judgment for convergence of nonlinear

NonlinearSpeedup Flag
0 or Off
1 or On

Flag of Using Nonlinear Speeding-up Function
Do not use speeding up nonlinear calculation.
Use speeding up nonlinear calculation.

BHCorrection Flag
0 or Off
1 or On

Flag for applying a correction to the BH curve for frequency response analysis.
Do not apply BH curve correction.
Use BH curve correction.

MagneticFluxDensity Flag
0 or Off
1 or On

The flag for output magnetic flux density result
Not output the magnetic flux density.
Output the magnetic flux density.

Magnetization Flag
0 or Off
1 or On

The flag for output magnetization
Not output the magnetization.
Output the magnetization.

PermeanceFactor Flag
0 or Off
1 or On

The flag for output permeance factor
Not output the permeance factor.
Output the permeance factor.

Permeability Flag
0 or Off
1 or On

The flag for output permeability
Not output the permeability.
Output the permeability.

DifferentialPermeability Flag
0 or Off
1 or On

The flag for output differential permeability
Not output the differential permeability.
Output the differential permeability.

CurrentDensity Flag
0 or Off
1 or On

The flag for output current density result
Not output the current density.
Output the current density.

LossDensity Flag
0 or Off
1 or On

The flag for output loss density
Not output the loss density.
Output the loss density.

Displacement Flag
0 or Off
1 or On

The flag for output nodal displacement result
Not output the nodal displacement.
Output the nodal displacement.

NodalForce Flag
0 or Off
1 or On

The flag for output nodal force result
Not output the nodal force.
Output the nodal force.

SurfaceForceDensity Flag
0 or Off
1 or On

The flag for surface force density
Not output the surface force density.
Output the surface force density.

LorentzForceDensity Flag
0 or Off
1 or On

The flag for output Lorentz force density
Not output the Lorentz force density.
Output the lorentz force density.

VectorPotential Flag
0 or Off
1 or On

The flag for output vector potential
Not output the vector potential.
Output the vector potential.

Energy Flag
0 or Off
1 or On

The flag for output energy result
Not output the energy.
Output the energy.

Stress Flag
0 or Off
1 or On

The flag for output stress result
Not output the stress.
Output the stress.

DemagnetizationRatio Flag
0 or Off
1 or On

The flag for output demagnetization ratio (Compared to reference step)
Not output the Demagnetization ratio (Compared to reference step).
Output the Demagnetization ratio (Compared to reference step).

DemagnetizationRatioDiffUnDemag Flag
0 or Off
1 or On

The flag for output demagnetization ratio (Compared to undemagnetized state)
Not output the Demagnetization ratio (Compared to undemagnetized state).
Output the Demagnetization ratio (Compared to undemagnetized state).

HysteresisLossDensity Flag
0 or Off
1 or On

The flag for output hysteresis loss density
Not output the hysteresis loss density
Output the hysteresis loss density

RestartFile Flag
0 or Off
1 or On

The flag for output restart file
Not output the restart file.
Output the restart file.

RestartFileOutputInterval Flag

The minimum output interval(minute) for restart file

JCGMonitor Flag
0 or Off
1 or On

The flag for output ICCG Iteration Count Monitoring file.
Not output the JCG monitor.
Output the JCG monitor.

SolverReportFile Flag
0 or Off
1 or On

The flag for output solver report file
Not output the solver report file.
Output the solver report file.

InitialMagnetization Flag
0 or Off
1 or On

The flag for initial magnetization
Not output the initial magnetization.
Output the initial magnetization.

CoerciveForceNormal Flag
0 or Off
1 or On

The flag to control output of normalized Coercive Force
Do not output the normalized coercive force.
Output the normalized coercive force.

MagnetizationRatio Flag
0 or Off
1 or On

The flag to control output of magnetization ratio
Do not output the magnetization ratio.
Output the magnetization ratio.

Temperature Flag
0 or Off
1 or On

The flag for output temperature
Not output the temperature.
Output the temperature.

IronLossDensity Flag
0 or Off
1 or On

The flag for output iron loss density
Not output the ironloss density.
Output the ironloss density.

ElectricField Flag
0 or Off
1 or On

The flag for output electric field result
Not output the electric field.
Output the electric field.

MagneticFluxDensityLamination Flag
0 or Off
1 or On

The flag to output lamination magnetic flux density
Not output the lamination magnetic flux density
Output the lamination magnetic flux density

MagneticFieldStrengthLamination Flag
0 or Off
1 or On

The flag to output lamination magnetic field strength
Not output the lamination magnetic field strength
Output the lamination magnetic field strength

EddyCurrentDensityLamination Flag
0 or Off
1 or On

The flag to output lamination eddy current density
Not output the lamination eddy current density
Output the lamination eddy current density

CurrentLossDensityLamination Flag
0 or Off
1 or On

The flag to output lamination current loss density
Not output the lamination current loss density
Output the lamination current loss density

HysteresisLossDensityLamination Flag
0 or Off
1 or On

The flag to output lamination hysteresis loss density
Not output the lamination hysteresis loss density
Output the lamination hysteresis loss density

CriticalCurrentDensity Flag
0 or Off
1 or On

The flag to output critical current density
Not output the critical current density
Output the critical current density

IronRefMagneticFluxDensity Flag
0 or Off
1 or On

The flag for output reference magnetic flux density result (Iron)
Not output the reference magnetic flux density (Iron)
Output the reference magnetic flux density (Iron)

IronIronLossDensity Flag
0 or Off
1 or On

The flag for output iron loss density (Iron)
Not output the iron loss density (Iron)
Output the iron loss density (Iron)

IronHysteresisLossDensity Flag
0 or Off
1 or On

The flag for output hysteresis loss density (Iron)
Not output the hysteresis loss density (Iron)
Output the hysteresis loss density (Iron)

IronExcessEddyCurrentDensity Flag
0 or Off
1 or On

The flag for output excess eddy current loss density (Iron)
Not output the excess eddy current loss density (Iron)
Output the excess eddy current loss density (Iron)

IronClassicalEddyCurrentDensity Flag
0 or Off
1 or On

The flag for output classical eddy current loss density (Iron)
Not output the classical eddy current loss density (Iron)
Output the classical eddy current loss density (Iron)

IronJouleLossDensity Flag
0 or Off
1 or On

The flag for output Joule loss density (Iron)
Not output the Joule loss density (Iron)
Output the Joule loss density (Iron)

IronStress Flag
0 or Off
1 or On

The flag for output stress result (Iron)
Not output the stress (Iron)
Output the stress (Iron)

IronMagneticFluxDensityLamination Flag
0 or Off
1 or On

The flag to output lamination magnetic flux density (Iron)
Not output the lamination magnetic flux density (Iron)
Output the lamination magnetic flux density (Iron)

IronMagneticFieldStrengthLamination Flag
0 or Off
1 or On

The flag to output lamination magnetic field strength (Iron)
Not output the lamination magnetic field strength (Iron)
Output the lamination magnetic field strength (Iron)

IronEddyCurrentDensityLamination Flag
0 or Off
1 or On

The flag to output lamination eddy current density (Iron)
Not output the lamination eddy current density (Iron)
Output the lamination eddy current density (Iron)

IronCurrentLossDensityLamination Flag
0 or Off
1 or On

The flag to output lamination current loss density (Iron)
Not output the lamination current loss density (Iron)
Output the lamination current loss density (Iron)

IronHysteresisLossDensityLamination Flag
0 or Off
1 or On

The flag to output lamination hysteresis loss density (Iron)
Not output the lamination hysteresis loss density (Iron)
Output the lamination hysteresis loss density (Iron)

OutputTimingMode Flag
0 or Off
1 or FromStep
1 or On
2 or SpecifyInterval

A flag to control timing of output to plot file
Always output from 1st step.
Output from step specified in OutputStartStep.
Output from step specified in OutputStartStep.
Output from step specified Interval.

OutputStartStep Flag

The first step to use for the output

MinimizeResults Flag
0 or Off
1 or On

Flag to control minimization of output results
Do not minimize output of distributed results for output control
Minimize output of distributed results for output control

OutputIntervalTable Table

output control interval table

OutputTimingSameStep Flag
0 or Off
1 or On

Flag to use same step by table and field results
Output another step by table and field results
Output same step by table and field results

OutputResultsTimingMode Flag
0 or Off
1 or FromStep
1 or On
2 or SpecifyInterval
3 or NoOutput

Flag to control step output to result file
Output all steps
Output from step specified by OutputResultStartStep
Output from step specified by OutputResultStartStep
Output from step specified Interval
No Output

OutputResultsStartStep Flag

The first step to use for the output

OutputResultsIntervalTable Table

output control interval table

Hsusr1 Flag
0 or Off
1 or On

Flag of User Subroutine "hsusr1"
Do Not Use User Subroutine "hsusr1"
Use User Subroutine "hsusr1"

Hsusr3 Flag
0 or Off
1 or On

Flag of User Subroutine "hsusr3"
Do Not Use User Subroutine "hsusr3"
Use User Subroutine "hsusr3"

Hsusr4 Flag
0 or Off
1 or On

Flag of User Subroutine "hsusr4"
Do Not Use User Subroutine "hsusr4"
Use User Subroutine "hsusr4"

Usrfle Flag
0 or Off
1 or On

Flag of User Subroutine "usrfle"
Do Not Use User Subroutine "usrfle"
Use User Subroutine "usrfle"

Usrstp Flag
0 or Off
1 or On

Flag of User Subroutine "usrstp"
Do Not Use User Subroutine "usrstp"
Use User Subroutine "usrstp"

Usrlos Flag
0 or Off
1 or On

Flag of User Subroutine "usrlos"
Do Not Use User Subroutine "usrlos"
Use User Subroutine "usrlos"

Usrhys Flag
0 or Off
1 or On

Flag of User Subroutine "usrhys"
Do Not Use User Subroutine "usrhys"
Use User Subroutine "usrhys"

Usrfm2 Flag
0 or Off
1 or On

Flag of User Subroutine "usrfm2"
Do Not Use User Subroutine "usrfm2"
Use User Subroutine "usrfm2"

Usrfma Flag
0 or Off
1 or On
2 or usrfm3

The flag of user subroutine "usrfma"
Not use user subroutine "usrfma"
Use user subroutine "usrfma"
Use user subroutine "usrfm3"

Usrstr Flag
0 or Off
1 or On

The flag of user subroutine "usrstr"
Not use user subroutine "usrstr"
Use user subroutine "usrstr"

UsrArraySize Flag

The size of users subroutine point array

UsrsubName String

User Subroutine Name

Snapshot Flag
0 or Off
1 or On

The flag for Snapshot
Not use Snapshot
Use Snapshot

Retry Flag

Number of retries

Divisions Flag

Number of steps divided

Monitor Flag
0 or Off
1 or On

The flag to output monitoring file during analysis execution
Do not output the monitoring file during analysis execution
Output a monitoring file during analysis execution

CsvOutputPath String

The output path for the csv files

CsvResultTypes String

The list of result types to output the csv files

CsvOutputResponseData Flag

CSV file output response value

CsvOutputInductanceData Flag

CSV file output efficiency map inductance values

CsvOutputProbe Flag

CSV file output probe value

CsvOutputSection Flag

CSV file output section graph value

CsvOutputCalculation Flag

CSV file output calculation value

CsvOutputObjectiveData Flag

CSV file output objective value

CsvComponentType Flag
0 or RealImaginary
1 or AmplitudePhase
2 or RMS

Flag of component output type
Output real and imaginary
Output amplitude and phase
Output rms

CsvDivisionType Flag
0 or Off
1 or On

Flag of divide CSV file output by specified number of cases
Do not divide
Divide CSV output

CsvDivisionCase Flag

Specified number of cases

OutputControlType Flag
0 or SpecifyOutputResultItems
1 or OutputTableOnly
2 or DeleteResultFiles

The output control type
Specify Result Items to be Output.
Output only table results.
Delete result files.

LogOutputLevel Flag
0 or Debug
1 or Information
2 or Warning
3 or Error
The log output level
Debug
Information
Warning
Error

SteadyState(SteadyState)

Property
(propName)
Type
(Type)
Flag
(scriptKeyName)

Description

SteadyStateStopCheckMethod Flag
0 or Maximum
1 or Instantaneous
2 or Average
3 or Frequency

The stop method used for the steady state
Maximum value
Instantaneous Value
Average Value
Frequency Component

SteadyStatePeriodic Double

The Periodic used to determine steady state

SteadyStateFrequency Double

The frequency used to determine steady state

HarmonicOrder Flag

Harmonic Order

SteadyStateThreshold Double

The threshold used for the steady state

SteadyStatePhaseThreshold Double

The phase threshold used for the steady state

UsePhaseStationary Flag
0 or Off
1 or On

Use phase stationary
Do not use phase stationary
Use phase stationary

SteadyStateReferenceResultSource Flag
1 or Torque
2 or Force
3 or FEMCoil
4 or FEMConductor
5 or CurrentCondition
6 or FluxCondition
7 or MotionDisplacement
8 or MotionSpeed
9 or Loss
10 or Voltage
11 or Current
12 or ControlSignal
13 or Temperature

The type of result used for the steady state
Torque results
Force results
FEM Coil (Flux)
FEM Conductor (Flux)
Current Condition (Flux)
Flux Condition (Flux)
Motion (displacement)
Motion (speed)
Loss value
Voltage probe
Current probe
Control signal probe
Temperature probe

SteadyStateVoltageProbe Int

Voltage probe for steady state

SteadyStateCircuitCurrent Int

Circuit component for current for steady state

SteadyStateControleProbe Int

Control probe for steady state

SteadyStateTemperatureProbe Int

Temperature probe for steady state

SteadyStateResultComponent Flag
0 or Absolute
1 or First
2 or Second
3 or Third

The component of the result used for the steady state
Absolute value of the result
The first (X) component
The second (Y) component
The third (Z) component

SteadyStateLinkedTorque Int

Linked torque condition for steady state

SteadyStateLinkedForce Int

Linked force condition for steady state

SteadyStateLinkedCoil Int

Linked FEM Coil for steady state

SteadyStateLinkedConductor Int

Linked FEM Conductor for steady state

SteadyStateLinkedCurrent Int

Linked current condition for steady state

SteadyStateLinkedFlux Int

Linked flux condition for steady state

SteadyStateLinkedDisplacement Int

Linked motion displacement for steady state

SteadyStateLinkedSpeed Int Linked motion speed for steady state

Study Properties(Control)

Control properties

Property
(propName)
Type
(Type)
Flag
(scriptKeyName)

Description

FullModelConversion Flag
0 or Off
1 or On

Flag for Conversion to Value in Full Model
The result is not converted as a full model.
The result is converted as a full model.

ConversionFactor Double

Conversion factor excluding periodic boundary

Coupling Flag
0 or Off
1 or On

Flag for Coupled Analysis
Do not run the Coupled Analysis.
Run the coupled analysis.

CoupledRemesh Flag
0 or Off
1 or On

The flag for coupled remesh region
The region is not coupled remesh.
The air region is coupled remesh.

ConversionType Flag
0 or NotUse
1 or Periodic
2 or SeriesParallel

The flag of circuit conversion type
The circuit conversion is not used.
The periodic conversion type
The circuit conversion type for series/parallel

CircuitConversionFactor Double

The conversion factor of circuit

CircuitConnect Flag
0 or Series
1 or Parallel
2 or AntiParallel

The circuit connect information
The series type
The parallel type
The anti parallel type

PowerCalcTolerance Double

The power calculation tolerance

PowerCalcInitialCurrent Double

The power calculation initial current

PowerCalcMaxIteration Flag

The calculation max iteration

Series Double

The number of series

Parallel Double

The number of parallel

ConnectionMode Flag
0 or ModifiedNodal
1 or ClosedLoop

Ths circuit analysis method
The modified nodal analysis type
The closed loop current analysis type

UseWindingFactor Flag
0 or Off
1 or On

The flag of use conversion factors from winding
Set conversion factors manually
Set conversion factors from winding

UseForceCorrection Flag
0 or Off
1 or On

The Force Correction
The force correction is not used.
The force correction is used.

SymmetryPlane1 Coordinate

The symmetry plane 1 for the force correction

SymmetryPlane2 Coordinate

The symmetry plane 2 for the force correction

ApproximateTransientAnalysis Flag
0 or Off
1 or On

The flag for use steady-state approximate transient analysis
Do not use steady-state approximate transient analysis
Use steady-state approximate transient analysis

SpecifySlip Flag
0 or Off
1 or On

The flag for stationary device or induction motor
Set as stationary device.
User can specify slip as induction motor.

SteadyLinear Flag
0 or Nonlinear
1 or Linear

The flag to control non-linear type for pseudo steady state analysis.
Use conventional method of quasi steady state analysis.
Use fast acceleration of quasi-steady state analysis.

Slip Double

Slip value(s <= 1)

OutputSteadyResultAs1stStep Flag
0 or Off
1 or On

The flag for output steady result as 1st step
Do not output steady result as 1st step
Output steady result as 1st step

SetPseudoSteadyStateFreq Flag
0 or Off
1 or On

The flag for setting pseudo-steady state frequency
Do not use frequency for pseudo steady-state
Use frequency for pseudo steady-state

PseudoSteadyStateFrequency Double

pseudo steady-state frequency

SetUseCorrectBHCurve Flag
0 or Off
1 or On

The flag for using correct bh curve for pseudo-steady state
Do not use correct bh curve for pseudo steady-state
Use correct bh curve for pseudo steady-state

TimePeriodicEEC Flag
0 or Off
1 or On

The flag for time periodic explicit error correction
The time periodic explicit error correction is not executed.
The time periodic explicit error correction is executed.

TimePeriodicType Flag
1 or AntiPeriodic
2 or Periodic

The flag of time periodic type
Anti-Periodic
Periodic

ReversePeriodic Flag
0 or Off
1 or On

The flag reverse periodic rotor
The reverse periodic rotor is not used.
The reverse periodic rotor is used.

UseRelaxation Flag
0 or Off
1 or On

The flag use non-linear relaxation
Non-linear relaxation is not used
Use non-linear relaxation.

CorrectionType Flag
0 or frequency
1 or step

The flag for correction type
The correction type is frequency.
The correction type is step.

CorrectionFrequency Double

Frequency of correction

CorrectionInterval Flag

Interval of correction step

MaxCorrections Flag

Max number of correction process

FailureConvergenceError Flag
0 or Off
1 or On

The flag to handle the failure of convergence as an error
Warning.
Error(Solver will terminate).

CalculateDisplacementCurrentInAir Flag
0 or Off
1 or On

The flag to control calculation of displacement currents in air regions
Do not calculate displacement currents in air regions.
Calculate displacement currents in air regions.

ShortenCorrectionInterval Flag
0 or Off
1 or On

The flag for shortening interval check
Do usual interval check.
Shorten interval check.

AllStepsTransientCalculation Flag
0 or Off
1 or On

The flag for calculate and output all steps of transient calculation
Do not calculate and output all steps of transient calculation.
Calculate and output all steps of transient calculation.

UseGPU Flag
0 or Off
1 or On

The flag for use GPU
Not use GPU.
Use GPU.

RestartType Flag
0 or NotRestart
1 or FromTR
2 or FromFQ

The restart type
Do not use restart.
Restart from transient analysis
Restart from frequency analysis

RestartSavFile String

The sav file for restart

RestartMsvFile String

The msv file for restart

RestartSvcFile String

The svc file for restart

DirectSolverType Flag
0 or ICCG
1 or Direct

The flag of linear solver type
ICCG
Direct solver

IccgAccel Double

Value of Acceleration Coefficient

AutoAccel Flag
0 or Off
1 or On

Flag to Set Acceleration Coefficient Automatically
The acceleration coefficient is set in manual.
The acceleration coefficient is automatically set.

ICCGToleranceType Flag
1 or Automatic
2 or Constant
4 or ScaleIndependent

Flag of ICCG Calculation Type
The ICCG tolerance is scaled using the original matrix right hand side vector. The tolerance is then adjusted automatically at each iteration.
The same ICCG tolerance is used for all NR iterations and is scaled using the original matrix right hand side vector.
The ICCG tolerance is scaled by the residual independently for each matrix solution.

InitialTolerance Double

Value of Initial Convergence Tolerance

MinimumTolerance Double

Value of Minimum Convergence Tolerance.

IccgTolerance Double

Value of Convergence Tolerance

IccgLimit Double

Value of Divergence Limit

IccgMaxIteration Flag

Value of Maximum Iteration

IccgToleranceScaleIndependent Double

The value of convergence tolerance.(Scale independent)

IccgOptimumValue Flag
0 or Off
1 or On

Flag of Convergence Refinement
No Refinement
Optimum Refinement

APhiMethod Flag
0 or Off
1 or Method1
1 or On
2 or Method2

Flag of Using A-Phi Method for Calculation
Do Not Use A-Phi Method
Use A-Phi method1
Use A-Phi method1
Use A-Phi method2 (recommended)

NonlinearMethod Flag
0 or Newton-Raphson
1 or SuccessiveIteration

Nonlinear Iterative Calculation Type
Newton-Raphson
Successive Iteration

ConvergenceType Flag
0 or Solution
1 or ResidualVector
2 or MagneticFluxDensityAndCircuit
3 or SolutionExcludingCircuit
4 or ResidualVectorExcludingCircuit
5 or MagneticFluxDensity

Convergence determination type
Using Variation of Solution
Using Magnitude of Residual Vector
Using Variation of Magnetic Flux Density and Circuit Variables
Using Variation of Solution (Excluding Circuit Variables)
Using Magnitude of Residual Vector (Excluding Circuit Variables)
Using Variation of Magnetic Flux Density

RelaxationFactor Flag
0 or Off
1 or Type1
2 or Type2
5 or FactorAuto

Flag of Relaxation Factor Type
No Relaxation
Relaxation Type 1
The relaxation type2
The relaxation auto

NonlinearMaxIteration Flag

Number of Nonlinear Iteration

NonlinearTolerance Double

Value of Nonlinear Iterative Convergence Tolerance

NonlinearConvergenceB Flag
0 or Off
1 or On

The maximum amount of change flag of the magnetic flux density
Not set the maximum amount of change in the magnetic flux density
To set the maximum amount of change in the magnetic flux density

NonlinearConvergenceV Flag
0 or Off
1 or On

The maximum amount of change flag of the voltage
Not set the maximum amount of change in the voltage
To set the maximum amount of change in the voltage

NonlinearConvergenceI Flag
0 or Off
1 or On

The maximum amount of change flag of the current
Not set the maximum amount of change in the current
To set the maximum amount of change in the current

NonlinearConvergenceToleranceB Double

The maximum amount of change in the magnetic flux density

NonlinearConvergenceToleranceV Double

The maximum amount of change in the voltage

NonlinearConvergenceToleranceI Double

The maximum amount of change in the current

NonlinearStrictConvergence Flag
0 or Off
0 or Off
1 or On
1 or On

Flag of Strict Judgment of Nonlinear Iterative Calculation
Normal judgment for convergence of nonlinear
Normal judgment for convergence of nonlinear
Strict judgment for convergence of nonlinear
Strict judgment for convergence of nonlinear

NonlinearSpeedup Flag
0 or Off
1 or On

Flag of Using Nonlinear Speeding-up Function
Do not use speeding up nonlinear calculation.
Use speeding up nonlinear calculation.

BHCorrection Flag
0 or Off
1 or On

Flag for applying a correction to the BH curve for frequency response analysis.
Do not apply BH curve correction.
Use BH curve correction.

MagneticFluxDensity Flag
0 or Off
1 or On

The flag for output magnetic flux density result
Not output the magnetic flux density.
Output the magnetic flux density.

Magnetization Flag
0 or Off
1 or On

The flag for output magnetization
Not output the magnetization.
Output the magnetization.

PermeanceFactor Flag
0 or Off
1 or On

The flag for output permeance factor
Not output the permeance factor.
Output the permeance factor.

Permeability Flag
0 or Off
1 or On

The flag for output permeability
Not output the permeability.
Output the permeability.

DifferentialPermeability Flag
0 or Off
1 or On

The flag for output differential permeability
Not output the differential permeability.
Output the differential permeability.

CurrentDensity Flag
0 or Off
1 or On

The flag for output current density result
Not output the current density.
Output the current density.

LossDensity Flag
0 or Off
1 or On

The flag for output loss density
Not output the loss density.
Output the loss density.

Displacement Flag
0 or Off
1 or On

The flag for output nodal displacement result
Not output the nodal displacement.
Output the nodal displacement.

NodalForce Flag
0 or Off
1 or On

The flag for output nodal force result
Not output the nodal force.
Output the nodal force.

SurfaceForceDensity Flag
0 or Off
1 or On

The flag for surface force density
Not output the surface force density.
Output the surface force density.

LorentzForceDensity Flag
0 or Off
1 or On

The flag for output Lorentz force density
Not output the Lorentz force density.
Output the lorentz force density.

VectorPotential Flag
0 or Off
1 or On

The flag for output vector potential
Not output the vector potential.
Output the vector potential.

Energy Flag
0 or Off
1 or On

The flag for output energy result
Not output the energy.
Output the energy.

Stress Flag
0 or Off
1 or On

The flag for output stress result
Not output the stress.
Output the stress.

DemagnetizationRatio Flag
0 or Off
1 or On

The flag for output demagnetization ratio (Compared to reference step)
Not output the Demagnetization ratio (Compared to reference step).
Output the Demagnetization ratio (Compared to reference step).

DemagnetizationRatioDiffUnDemag Flag
0 or Off
1 or On

The flag for output demagnetization ratio (Compared to undemagnetized state)
Not output the Demagnetization ratio (Compared to undemagnetized state).
Output the Demagnetization ratio (Compared to undemagnetized state).

HysteresisLossDensity Flag
0 or Off
1 or On

The flag for output hysteresis loss density
Not output the hysteresis loss density
Output the hysteresis loss density

RestartFile Flag
0 or Off
1 or On

The flag for output restart file
Not output the restart file.
Output the restart file.

RestartFileOutputInterval Flag

The minimum output interval(minute) for restart file

JCGMonitor Flag
0 or Off
1 or On

The flag for output ICCG Iteration Count Monitoring file.
Not output the JCG monitor.
Output the JCG monitor.

SolverReportFile Flag
0 or Off
1 or On

The flag for output solver report file
Not output the solver report file.
Output the solver report file.

InitialMagnetization Flag
0 or Off
1 or On

The flag for initial magnetization
Not output the initial magnetization.
Output the initial magnetization.

CoerciveForceNormal Flag
0 or Off
1 or On

The flag to control output of normalized Coercive Force
Do not output the normalized coercive force.
Output the normalized coercive force.

MagnetizationRatio Flag
0 or Off
1 or On

The flag to control output of magnetization ratio
Do not output the magnetization ratio.
Output the magnetization ratio.

Temperature Flag
0 or Off
1 or On

The flag for output temperature
Not output the temperature.
Output the temperature.

IronLossDensity Flag
0 or Off
1 or On

The flag for output iron loss density
Not output the ironloss density.
Output the ironloss density.

ElectricField Flag
0 or Off
1 or On

The flag for output electric field result
Not output the electric field.
Output the electric field.

MagneticFluxDensityLamination Flag
0 or Off
1 or On

The flag to output lamination magnetic flux density
Not output the lamination magnetic flux density
Output the lamination magnetic flux density

MagneticFieldStrengthLamination Flag
0 or Off
1 or On

The flag to output lamination magnetic field strength
Not output the lamination magnetic field strength
Output the lamination magnetic field strength

EddyCurrentDensityLamination Flag
0 or Off
1 or On

The flag to output lamination eddy current density
Not output the lamination eddy current density
Output the lamination eddy current density

CurrentLossDensityLamination Flag
0 or Off
1 or On

The flag to output lamination current loss density
Not output the lamination current loss density
Output the lamination current loss density

HysteresisLossDensityLamination Flag
0 or Off
1 or On

The flag to output lamination hysteresis loss density
Not output the lamination hysteresis loss density
Output the lamination hysteresis loss density

CriticalCurrentDensity Flag
0 or Off
1 or On

The flag to output critical current density
Not output the critical current density
Output the critical current density

IronRefMagneticFluxDensity Flag
0 or Off
1 or On

The flag for output reference magnetic flux density result (Iron)
Not output the reference magnetic flux density (Iron)
Output the reference magnetic flux density (Iron)

IronIronLossDensity Flag
0 or Off
1 or On

The flag for output iron loss density (Iron)
Not output the iron loss density (Iron)
Output the iron loss density (Iron)

IronHysteresisLossDensity Flag
0 or Off
1 or On

The flag for output hysteresis loss density (Iron)
Not output the hysteresis loss density (Iron)
Output the hysteresis loss density (Iron)

IronExcessEddyCurrentDensity Flag
0 or Off
1 or On

The flag for output excess eddy current loss density (Iron)
Not output the excess eddy current loss density (Iron)
Output the excess eddy current loss density (Iron)

IronClassicalEddyCurrentDensity Flag
0 or Off
1 or On

The flag for output classical eddy current loss density (Iron)
Not output the classical eddy current loss density (Iron)
Output the classical eddy current loss density (Iron)

IronJouleLossDensity Flag
0 or Off
1 or On

The flag for output Joule loss density (Iron)
Not output the Joule loss density (Iron)
Output the Joule loss density (Iron)

IronStress Flag
0 or Off
1 or On

The flag for output stress result (Iron)
Not output the stress (Iron)
Output the stress (Iron)

IronMagneticFluxDensityLamination Flag
0 or Off
1 or On

The flag to output lamination magnetic flux density (Iron)
Not output the lamination magnetic flux density (Iron)
Output the lamination magnetic flux density (Iron)

IronMagneticFieldStrengthLamination Flag
0 or Off
1 or On

The flag to output lamination magnetic field strength (Iron)
Not output the lamination magnetic field strength (Iron)
Output the lamination magnetic field strength (Iron)

IronEddyCurrentDensityLamination Flag
0 or Off
1 or On

The flag to output lamination eddy current density (Iron)
Not output the lamination eddy current density (Iron)
Output the lamination eddy current density (Iron)

IronCurrentLossDensityLamination Flag
0 or Off
1 or On

The flag to output lamination current loss density (Iron)
Not output the lamination current loss density (Iron)
Output the lamination current loss density (Iron)

IronHysteresisLossDensityLamination Flag
0 or Off
1 or On

The flag to output lamination hysteresis loss density (Iron)
Not output the lamination hysteresis loss density (Iron)
Output the lamination hysteresis loss density (Iron)

OutputTimingMode Flag
0 or Off
1 or FromStep
1 or On
2 or SpecifyInterval

A flag to control timing of output to plot file
Always output from 1st step.
Output from step specified in OutputStartStep.
Output from step specified in OutputStartStep.
Output from step specified Interval.

OutputStartStep Flag

The first step to use for the output

MinimizeResults Flag
0 or Off
1 or On

Flag to control minimization of output results
Do not minimize output of distributed results for output control
Minimize output of distributed results for output control

OutputIntervalTable Table

output control interval table

OutputTimingSameStep Flag
0 or Off
1 or On

Flag to use same step by table and field results
Output another step by table and field results
Output same step by table and field results

OutputResultsTimingMode Flag
0 or Off
1 or FromStep
1 or On
2 or SpecifyInterval
3 or NoOutput

Flag to control step output to result file
Output all steps
Output from step specified by OutputResultStartStep
Output from step specified by OutputResultStartStep
Output from step specified Interval
No Output

OutputResultsStartStep Flag

The first step to use for the output

OutputResultsIntervalTable Table

output control interval table

Hsusr1 Flag
0 or Off
1 or On

Flag of User Subroutine "hsusr1"
Do Not Use User Subroutine "hsusr1"
Use User Subroutine "hsusr1"

Hsusr3 Flag
0 or Off
1 or On

Flag of User Subroutine "hsusr3"
Do Not Use User Subroutine "hsusr3"
Use User Subroutine "hsusr3"

Hsusr4 Flag
0 or Off
1 or On

Flag of User Subroutine "hsusr4"
Do Not Use User Subroutine "hsusr4"
Use User Subroutine "hsusr4"

Usrfle Flag
0 or Off
1 or On

Flag of User Subroutine "usrfle"
Do Not Use User Subroutine "usrfle"
Use User Subroutine "usrfle"

Usrstp Flag
0 or Off
1 or On

Flag of User Subroutine "usrstp"
Do Not Use User Subroutine "usrstp"
Use User Subroutine "usrstp"

Usrlos Flag
0 or Off
1 or On

Flag of User Subroutine "usrlos"
Do Not Use User Subroutine "usrlos"
Use User Subroutine "usrlos"

Usrhys Flag
0 or Off
1 or On

Flag of User Subroutine "usrhys"
Do Not Use User Subroutine "usrhys"
Use User Subroutine "usrhys"

Usrfm2 Flag
0 or Off
1 or On

Flag of User Subroutine "usrfm2"
Do Not Use User Subroutine "usrfm2"
Use User Subroutine "usrfm2"

Usrfma Flag
0 or Off
1 or On
2 or usrfm3

The flag of user subroutine "usrfma"
Not use user subroutine "usrfma"
Use user subroutine "usrfma"
Use user subroutine "usrfm3"

Usrstr Flag
0 or Off
1 or On

The flag of user subroutine "usrstr"
Not use user subroutine "usrstr"
Use user subroutine "usrstr"

UsrArraySize Flag

The size of users subroutine point array

UsrsubName String

User Subroutine Name

Snapshot Flag
0 or Off
1 or On

The flag for Snapshot
Not use Snapshot
Use Snapshot

Retry Flag

Number of retries

Divisions Flag

Number of steps divided

Monitor Flag
0 or Off
1 or On

The flag to output monitoring file during analysis execution
Do not output the monitoring file during analysis execution
Output a monitoring file during analysis execution

CsvOutputPath String

The output path for the csv files

CsvResultTypes String

The list of result types to output the csv files

CsvOutputResponseData Flag

CSV file output response value

CsvOutputInductanceData Flag

CSV file output efficiency map inductance values

CsvOutputProbe Flag

CSV file output probe value

CsvOutputSection Flag

CSV file output section graph value

CsvOutputCalculation Flag

CSV file output calculation value

CsvOutputObjectiveData Flag

CSV file output objective value

CsvComponentType Flag
0 or RealImaginary
1 or AmplitudePhase
2 or RMS

Flag of component output type
Output real and imaginary
Output amplitude and phase
Output rms

CsvDivisionType Flag
0 or Off
1 or On

Flag of divide CSV file output by specified number of cases
Do not divide
Divide CSV output

CsvDivisionCase Flag

Specified number of cases

OutputControlType Flag
0 or SpecifyOutputResultItems
1 or OutputTableOnly
2 or DeleteResultFiles

The output control type
Specify Result Items to be Output.
Output only table results.
Delete result files.

LogOutputLevel Flag
0 or Debug
1 or Information
2 or Warning
3 or Error
The log output level
Debug
Information
Warning
Error

Study Properties(TransformerMagControl)

TransformerMagControl properties

Property
(propName)
Type
(Type)
Flag
(scriptKeyName)

Description

FullModelConversion Flag
0 or Off
1 or On

Flag for Conversion to Value in Full Model
The result is not converted as a full model.
The result is converted as a full model.

ConversionFactor Double

Conversion factor excluding periodic boundary

Coupling Flag
0 or Off
1 or On

Flag for Coupled Analysis
Do not run the Coupled Analysis.
Run the coupled analysis.

CoupledRemesh Flag
0 or Off
1 or On

The flag for coupled remesh region
The region is not coupled remesh.
The air region is coupled remesh.

ConversionType Flag
0 or NotUse
1 or Periodic
2 or SeriesParallel

The flag of circuit conversion type
The circuit conversion is not used.
The periodic conversion type
The circuit conversion type for series/parallel

CircuitConversionFactor Double

The conversion factor of circuit

CircuitConnect Flag
0 or Series
1 or Parallel
2 or AntiParallel

The circuit connect information
The series type
The parallel type
The anti parallel type

PowerCalcTolerance Double

The power calculation tolerance

PowerCalcInitialCurrent Double

The power calculation initial current

PowerCalcMaxIteration Flag

The calculation max iteration

Series Double

The number of series

Parallel Double

The number of parallel

ConnectionMode Flag
0 or ModifiedNodal
1 or ClosedLoop

Ths circuit analysis method
The modified nodal analysis type
The closed loop current analysis type

UseWindingFactor Flag
0 or Off
1 or On

The flag of use conversion factors from winding
Set conversion factors manually
Set conversion factors from winding

UseForceCorrection Flag
0 or Off
1 or On

The Force Correction
The force correction is not used.
The force correction is used.

SymmetryPlane1 Coordinate

The symmetry plane 1 for the force correction

SymmetryPlane2 Coordinate

The symmetry plane 2 for the force correction

ApproximateTransientAnalysis Flag
0 or Off
1 or On

The flag for use steady-state approximate transient analysis
Do not use steady-state approximate transient analysis
Use steady-state approximate transient analysis

SpecifySlip Flag
0 or Off
1 or On

The flag for stationary device or induction motor
Set as stationary device.
User can specify slip as induction motor.

SteadyLinear Flag
0 or Nonlinear
1 or Linear

The flag to control non-linear type for pseudo steady state analysis.
Use conventional method of quasi steady state analysis.
Use fast acceleration of quasi-steady state analysis.

Slip Double

Slip value(s <= 1)

OutputSteadyResultAs1stStep Flag
0 or Off
1 or On

The flag for output steady result as 1st step
Do not output steady result as 1st step
Output steady result as 1st step

SetPseudoSteadyStateFreq Flag
0 or Off
1 or On

The flag for setting pseudo-steady state frequency
Do not use frequency for pseudo steady-state
Use frequency for pseudo steady-state

PseudoSteadyStateFrequency Double

pseudo steady-state frequency

SetUseCorrectBHCurve Flag
0 or Off
1 or On

The flag for using correct bh curve for pseudo-steady state
Do not use correct bh curve for pseudo steady-state
Use correct bh curve for pseudo steady-state

TimePeriodicEEC Flag
0 or Off
1 or On

The flag for time periodic explicit error correction
The time periodic explicit error correction is not executed.
The time periodic explicit error correction is executed.

TimePeriodicType Flag
1 or AntiPeriodic
2 or Periodic

The flag of time periodic type
Anti-Periodic
Periodic

ReversePeriodic Flag
0 or Off
1 or On

The flag reverse periodic rotor
The reverse periodic rotor is not used.
The reverse periodic rotor is used.

UseRelaxation Flag
0 or Off
1 or On

The flag use non-linear relaxation
Non-linear relaxation is not used
Use non-linear relaxation.

CorrectionType Flag
0 or frequency
1 or step

The flag for correction type
The correction type is frequency.
The correction type is step.

CorrectionFrequency Double

Frequency of correction

CorrectionInterval Flag

Interval of correction step

MaxCorrections Flag

Max number of correction process

FailureConvergenceError Flag
0 or Off
1 or On

The flag to handle the failure of convergence as an error
Warning.
Error(Solver will terminate).

CalculateDisplacementCurrentInAir Flag
0 or Off
1 or On

The flag to control calculation of displacement currents in air regions
Do not calculate displacement currents in air regions.
Calculate displacement currents in air regions.

ShortenCorrectionInterval Flag
0 or Off
1 or On

The flag for shortening interval check
Do usual interval check.
Shorten interval check.

AllStepsTransientCalculation Flag
0 or Off
1 or On

The flag for calculate and output all steps of transient calculation
Do not calculate and output all steps of transient calculation.
Calculate and output all steps of transient calculation.

UseGPU Flag
0 or Off
1 or On

The flag for use GPU
Not use GPU.
Use GPU.

RestartType Flag
0 or NotRestart
1 or FromTR
2 or FromFQ

The restart type
Do not use restart.
Restart from transient analysis
Restart from frequency analysis

RestartSavFile String

The sav file for restart

RestartMsvFile String

The msv file for restart

RestartSvcFile String

The svc file for restart

DirectSolverType Flag
0 or ICCG
1 or Direct

The flag of linear solver type
ICCG
Direct solver

IccgAccel Double

Value of Acceleration Coefficient

AutoAccel Flag
0 or Off
1 or On

Flag to Set Acceleration Coefficient Automatically
The acceleration coefficient is set in manual.
The acceleration coefficient is automatically set.

ICCGToleranceType Flag
1 or Automatic
2 or Constant
4 or ScaleIndependent

Flag of ICCG Calculation Type
The ICCG tolerance is scaled using the original matrix right hand side vector. The tolerance is then adjusted automatically at each iteration.
The same ICCG tolerance is used for all NR iterations and is scaled using the original matrix right hand side vector.
The ICCG tolerance is scaled by the residual independently for each matrix solution.

InitialTolerance Double

Value of Initial Convergence Tolerance

MinimumTolerance Double

Value of Minimum Convergence Tolerance.

IccgTolerance Double

Value of Convergence Tolerance

IccgLimit Double

Value of Divergence Limit

IccgMaxIteration Flag

Value of Maximum Iteration

IccgToleranceScaleIndependent Double

The value of convergence tolerance.(Scale independent)

IccgOptimumValue Flag
0 or Off
1 or On

Flag of Convergence Refinement
No Refinement
Optimum Refinement

APhiMethod Flag
0 or Off
1 or Method1
1 or On
2 or Method2

Flag of Using A-Phi Method for Calculation
Do Not Use A-Phi Method
Use A-Phi method1
Use A-Phi method1
Use A-Phi method2 (recommended)

NonlinearMethod Flag
0 or Newton-Raphson
1 or SuccessiveIteration

Nonlinear Iterative Calculation Type
Newton-Raphson
Successive Iteration

ConvergenceType Flag
0 or Solution
1 or ResidualVector
2 or MagneticFluxDensityAndCircuit
3 or SolutionExcludingCircuit
4 or ResidualVectorExcludingCircuit
5 or MagneticFluxDensity

Convergence determination type
Using Variation of Solution
Using Magnitude of Residual Vector
Using Variation of Magnetic Flux Density and Circuit Variables
Using Variation of Solution (Excluding Circuit Variables)
Using Magnitude of Residual Vector (Excluding Circuit Variables)
Using Variation of Magnetic Flux Density

RelaxationFactor Flag
0 or Off
1 or Type1
2 or Type2
5 or FactorAuto

Flag of Relaxation Factor Type
No Relaxation
Relaxation Type 1
The relaxation type2
The relaxation auto

NonlinearMaxIteration Flag

Number of Nonlinear Iteration

NonlinearTolerance Double

Value of Nonlinear Iterative Convergence Tolerance

NonlinearConvergenceB Flag
0 or Off
1 or On

The maximum amount of change flag of the magnetic flux density
Not set the maximum amount of change in the magnetic flux density
To set the maximum amount of change in the magnetic flux density

NonlinearConvergenceV Flag
0 or Off
1 or On

The maximum amount of change flag of the voltage
Not set the maximum amount of change in the voltage
To set the maximum amount of change in the voltage

NonlinearConvergenceI Flag
0 or Off
1 or On

The maximum amount of change flag of the current
Not set the maximum amount of change in the current
To set the maximum amount of change in the current

NonlinearConvergenceToleranceB Double

The maximum amount of change in the magnetic flux density

NonlinearConvergenceToleranceV Double

The maximum amount of change in the voltage

NonlinearConvergenceToleranceI Double

The maximum amount of change in the current

NonlinearStrictConvergence Flag
0 or Off
0 or Off
1 or On
1 or On

Flag of Strict Judgment of Nonlinear Iterative Calculation
Normal judgment for convergence of nonlinear
Normal judgment for convergence of nonlinear
Strict judgment for convergence of nonlinear
Strict judgment for convergence of nonlinear

NonlinearSpeedup Flag
0 or Off
1 or On

Flag of Using Nonlinear Speeding-up Function
Do not use speeding up nonlinear calculation.
Use speeding up nonlinear calculation.

BHCorrection Flag
0 or Off
1 or On

Flag for applying a correction to the BH curve for frequency response analysis.
Do not apply BH curve correction.
Use BH curve correction.

MagneticFluxDensity Flag
0 or Off
1 or On

The flag for output magnetic flux density result
Not output the magnetic flux density.
Output the magnetic flux density.

Magnetization Flag
0 or Off
1 or On

The flag for output magnetization
Not output the magnetization.
Output the magnetization.

PermeanceFactor Flag
0 or Off
1 or On

The flag for output permeance factor
Not output the permeance factor.
Output the permeance factor.

Permeability Flag
0 or Off
1 or On

The flag for output permeability
Not output the permeability.
Output the permeability.

DifferentialPermeability Flag
0 or Off
1 or On

The flag for output differential permeability
Not output the differential permeability.
Output the differential permeability.

CurrentDensity Flag
0 or Off
1 or On

The flag for output current density result
Not output the current density.
Output the current density.

LossDensity Flag
0 or Off
1 or On

The flag for output loss density
Not output the loss density.
Output the loss density.

Displacement Flag
0 or Off
1 or On

The flag for output nodal displacement result
Not output the nodal displacement.
Output the nodal displacement.

NodalForce Flag
0 or Off
1 or On

The flag for output nodal force result
Not output the nodal force.
Output the nodal force.

SurfaceForceDensity Flag
0 or Off
1 or On

The flag for surface force density
Not output the surface force density.
Output the surface force density.

LorentzForceDensity Flag
0 or Off
1 or On

The flag for output Lorentz force density
Not output the Lorentz force density.
Output the lorentz force density.

VectorPotential Flag
0 or Off
1 or On

The flag for output vector potential
Not output the vector potential.
Output the vector potential.

Energy Flag
0 or Off
1 or On

The flag for output energy result
Not output the energy.
Output the energy.

Stress Flag
0 or Off
1 or On

The flag for output stress result
Not output the stress.
Output the stress.

DemagnetizationRatio Flag
0 or Off
1 or On

The flag for output demagnetization ratio (Compared to reference step)
Not output the Demagnetization ratio (Compared to reference step).
Output the Demagnetization ratio (Compared to reference step).

DemagnetizationRatioDiffUnDemag Flag
0 or Off
1 or On

The flag for output demagnetization ratio (Compared to undemagnetized state)
Not output the Demagnetization ratio (Compared to undemagnetized state).
Output the Demagnetization ratio (Compared to undemagnetized state).

HysteresisLossDensity Flag
0 or Off
1 or On

The flag for output hysteresis loss density
Not output the hysteresis loss density
Output the hysteresis loss density

RestartFile Flag
0 or Off
1 or On

The flag for output restart file
Not output the restart file.
Output the restart file.

RestartFileOutputInterval Flag

The minimum output interval(minute) for restart file

JCGMonitor Flag
0 or Off
1 or On

The flag for output ICCG Iteration Count Monitoring file.
Not output the JCG monitor.
Output the JCG monitor.

SolverReportFile Flag
0 or Off
1 or On

The flag for output solver report file
Not output the solver report file.
Output the solver report file.

InitialMagnetization Flag
0 or Off
1 or On

The flag for initial magnetization
Not output the initial magnetization.
Output the initial magnetization.

CoerciveForceNormal Flag
0 or Off
1 or On

The flag to control output of normalized Coercive Force
Do not output the normalized coercive force.
Output the normalized coercive force.

MagnetizationRatio Flag
0 or Off
1 or On

The flag to control output of magnetization ratio
Do not output the magnetization ratio.
Output the magnetization ratio.

Temperature Flag
0 or Off
1 or On

The flag for output temperature
Not output the temperature.
Output the temperature.

IronLossDensity Flag
0 or Off
1 or On

The flag for output iron loss density
Not output the ironloss density.
Output the ironloss density.

ElectricField Flag
0 or Off
1 or On

The flag for output electric field result
Not output the electric field.
Output the electric field.

MagneticFluxDensityLamination Flag
0 or Off
1 or On

The flag to output lamination magnetic flux density
Not output the lamination magnetic flux density
Output the lamination magnetic flux density

MagneticFieldStrengthLamination Flag
0 or Off
1 or On

The flag to output lamination magnetic field strength
Not output the lamination magnetic field strength
Output the lamination magnetic field strength

EddyCurrentDensityLamination Flag
0 or Off
1 or On

The flag to output lamination eddy current density
Not output the lamination eddy current density
Output the lamination eddy current density

CurrentLossDensityLamination Flag
0 or Off
1 or On

The flag to output lamination current loss density
Not output the lamination current loss density
Output the lamination current loss density

HysteresisLossDensityLamination Flag
0 or Off
1 or On

The flag to output lamination hysteresis loss density
Not output the lamination hysteresis loss density
Output the lamination hysteresis loss density

CriticalCurrentDensity Flag
0 or Off
1 or On

The flag to output critical current density
Not output the critical current density
Output the critical current density

IronRefMagneticFluxDensity Flag
0 or Off
1 or On

The flag for output reference magnetic flux density result (Iron)
Not output the reference magnetic flux density (Iron)
Output the reference magnetic flux density (Iron)

IronIronLossDensity Flag
0 or Off
1 or On

The flag for output iron loss density (Iron)
Not output the iron loss density (Iron)
Output the iron loss density (Iron)

IronHysteresisLossDensity Flag
0 or Off
1 or On

The flag for output hysteresis loss density (Iron)
Not output the hysteresis loss density (Iron)
Output the hysteresis loss density (Iron)

IronExcessEddyCurrentDensity Flag
0 or Off
1 or On

The flag for output excess eddy current loss density (Iron)
Not output the excess eddy current loss density (Iron)
Output the excess eddy current loss density (Iron)

IronClassicalEddyCurrentDensity Flag
0 or Off
1 or On

The flag for output classical eddy current loss density (Iron)
Not output the classical eddy current loss density (Iron)
Output the classical eddy current loss density (Iron)

IronJouleLossDensity Flag
0 or Off
1 or On

The flag for output Joule loss density (Iron)
Not output the Joule loss density (Iron)
Output the Joule loss density (Iron)

IronStress Flag
0 or Off
1 or On

The flag for output stress result (Iron)
Not output the stress (Iron)
Output the stress (Iron)

IronMagneticFluxDensityLamination Flag
0 or Off
1 or On

The flag to output lamination magnetic flux density (Iron)
Not output the lamination magnetic flux density (Iron)
Output the lamination magnetic flux density (Iron)

IronMagneticFieldStrengthLamination Flag
0 or Off
1 or On

The flag to output lamination magnetic field strength (Iron)
Not output the lamination magnetic field strength (Iron)
Output the lamination magnetic field strength (Iron)

IronEddyCurrentDensityLamination Flag
0 or Off
1 or On

The flag to output lamination eddy current density (Iron)
Not output the lamination eddy current density (Iron)
Output the lamination eddy current density (Iron)

IronCurrentLossDensityLamination Flag
0 or Off
1 or On

The flag to output lamination current loss density (Iron)
Not output the lamination current loss density (Iron)
Output the lamination current loss density (Iron)

IronHysteresisLossDensityLamination Flag
0 or Off
1 or On

The flag to output lamination hysteresis loss density (Iron)
Not output the lamination hysteresis loss density (Iron)
Output the lamination hysteresis loss density (Iron)

OutputTimingMode Flag
0 or Off
1 or FromStep
1 or On
2 or SpecifyInterval

A flag to control timing of output to plot file
Always output from 1st step.
Output from step specified in OutputStartStep.
Output from step specified in OutputStartStep.
Output from step specified Interval.

OutputStartStep Flag

The first step to use for the output

MinimizeResults Flag
0 or Off
1 or On

Flag to control minimization of output results
Do not minimize output of distributed results for output control
Minimize output of distributed results for output control

OutputIntervalTable Table

output control interval table

OutputTimingSameStep Flag
0 or Off
1 or On

Flag to use same step by table and field results
Output another step by table and field results
Output same step by table and field results

OutputResultsTimingMode Flag
0 or Off
1 or FromStep
1 or On
2 or SpecifyInterval
3 or NoOutput

Flag to control step output to result file
Output all steps
Output from step specified by OutputResultStartStep
Output from step specified by OutputResultStartStep
Output from step specified Interval
No Output

OutputResultsStartStep Flag

The first step to use for the output

OutputResultsIntervalTable Table

output control interval table

Hsusr1 Flag
0 or Off
1 or On

Flag of User Subroutine "hsusr1"
Do Not Use User Subroutine "hsusr1"
Use User Subroutine "hsusr1"

Hsusr3 Flag
0 or Off
1 or On

Flag of User Subroutine "hsusr3"
Do Not Use User Subroutine "hsusr3"
Use User Subroutine "hsusr3"

Hsusr4 Flag
0 or Off
1 or On

Flag of User Subroutine "hsusr4"
Do Not Use User Subroutine "hsusr4"
Use User Subroutine "hsusr4"

Usrfle Flag
0 or Off
1 or On

Flag of User Subroutine "usrfle"
Do Not Use User Subroutine "usrfle"
Use User Subroutine "usrfle"

Usrstp Flag
0 or Off
1 or On

Flag of User Subroutine "usrstp"
Do Not Use User Subroutine "usrstp"
Use User Subroutine "usrstp"

Usrlos Flag
0 or Off
1 or On

Flag of User Subroutine "usrlos"
Do Not Use User Subroutine "usrlos"
Use User Subroutine "usrlos"

Usrhys Flag
0 or Off
1 or On

Flag of User Subroutine "usrhys"
Do Not Use User Subroutine "usrhys"
Use User Subroutine "usrhys"

Usrfm2 Flag
0 or Off
1 or On

Flag of User Subroutine "usrfm2"
Do Not Use User Subroutine "usrfm2"
Use User Subroutine "usrfm2"

Usrfma Flag
0 or Off
1 or On
2 or usrfm3

The flag of user subroutine "usrfma"
Not use user subroutine "usrfma"
Use user subroutine "usrfma"
Use user subroutine "usrfm3"

Usrstr Flag
0 or Off
1 or On

The flag of user subroutine "usrstr"
Not use user subroutine "usrstr"
Use user subroutine "usrstr"

UsrArraySize Flag

The size of users subroutine point array

UsrsubName String

User Subroutine Name

Snapshot Flag
0 or Off
1 or On

The flag for Snapshot
Not use Snapshot
Use Snapshot

Retry Flag

Number of retries

Divisions Flag

Number of steps divided

Monitor Flag
0 or Off
1 or On

The flag to output monitoring file during analysis execution
Do not output the monitoring file during analysis execution
Output a monitoring file during analysis execution

CsvOutputPath String

The output path for the csv files

CsvResultTypes String

The list of result types to output the csv files

CsvOutputResponseData Flag

CSV file output response value

CsvOutputInductanceData Flag

CSV file output efficiency map inductance values

CsvOutputProbe Flag

CSV file output probe value

CsvOutputSection Flag

CSV file output section graph value

CsvOutputCalculation Flag

CSV file output calculation value

CsvOutputObjectiveData Flag

CSV file output objective value

CsvComponentType Flag
0 or RealImaginary
1 or AmplitudePhase
2 or RMS

Flag of component output type
Output real and imaginary
Output amplitude and phase
Output rms

CsvDivisionType Flag
0 or Off
1 or On

Flag of divide CSV file output by specified number of cases
Do not divide
Divide CSV output

CsvDivisionCase Flag

Specified number of cases

OutputControlType Flag
0 or SpecifyOutputResultItems
2 or DeleteResultFiles

The output control type
Specify Result Items to be Output.
Delete result files.

LogOutputLevel Flag
0 or Debug
1 or Information
2 or Warning
3 or Error
The log output level
Debug
Information
Warning
Error

Transformer Controll(TransformerControl)

TransformerControl properties

Property
(propName)
Type
(Type)
Flag
(scriptKeyName)

Description

FlgMode3dSt Flag
0 or Off
1 or On

Flag run as 3D ST mode
3D ST mode is off.
3D ST mode is on.

AnalysisType Flag
0 or Stack
1 or Cylindrical

Analysis type
Analysis type is stack.
Analysis type is cylindrical.

FlgUse3dCorrection Flag
0 or Off
1 or On

Flag use 3D correction
3D correction does not be used.
3D correction is used.

FlgUseCoreThicknessCorrection Flag
0 or Off
1 or On

Use correction of model thickness
Core thickness correction is off.
Core thickness correction is on.

CoreThickness Double

Model Thickness

FlgUseFqAnalysis Flag
0 or Off
1 or On
Flag use FQ analysis
FQ analysis does not be used.
FQ Analysis is used.

Common(Common)

Common properties

Property
(propName)
Type
(Type)
Flag
(scriptKeyName)

Description

UseMultiCPU Flag
0 or NonParallel
0 or Off
1 or SMP
1 or On
2 or MPP
2 or DMP

Flag for the use of multi cpu
Do not use multi cpu
Do not use multi cpu
Use SMP
Use SMP
Use MPP
Use DMP

MultiCPU Flag

Degree of parallelism for SMP

MppCPU Flag

MPP process parallelism

MppThread Flag

MPP thread parallelism

IronLossMode Flag
0 or Off
1 or On

The mode of calculation of iron loss conditions
Iron loss is calculated after magnetic field analysis has finished
Iron loss and magnetic field analysis are calculated concurrently

ParallelComputing Flag
0 or Off
1 or On
The flag of use parallel computing for iron loss conditions
Not use parallel computing for loss conditions
Use parallel computing for loss conditions

Step(TransientStep)

Property
(propName)
Type
(Type)
Flag
(scriptKeyName)

Description

Step Flag

The number of analysis steps

TimeStep Double

The value of time step

StepType Flag
0 or Simple
1 or Uniform
2 or Time

The step type: simple = 0, uniform = 1, time = 2
The interval step
The steps has uniform intervals
The steps is defined by time point array.

StepDivision Flag

The division of steps

EndPoint Double

The value of end point

Nonlinear Table

The nonlinear vs time point array

MaximumTime Double

Value of Maximum Progress

Angle Double

The value of movement angle

Distance Double

Value of Movement Distance

Division Table

Time vs Division Table

FirstEndTime Double

The end time of the first period

FirstDivision Flag

The number of divisions of the first period

SecondEndTime Double

The end time of the second period

SecondDivision Flag

The number of divisions of the second period

StopOnSteadyState Flag
0 or Off
1 or On
Stop the analysis when steady state is reached.
Do not stop
Stop analysis on steady state

Frequency Step(FrequencyStep)

Property
(propName)
Type
(Type)
Flag
(scriptKeyName)

Description

Step Flag

The number of analysis steps

StepType Flag
0 or Simple
1 or Uniform
2 or Frequency
3 or Section
4 or Time

The step type: simple = 0 , uniform = 1 , frequency = 2 , section = 3 , time = 4
Interval Step
The steps has uniform intervals
The steps is defined by frequency point array.
The steps is defined by section point array.
The steps is defined by time vs frequency point array.

FrequencyStep Double

The value of frequency step

Initialfrequency Double

The initial frequency

StartPoint Double

The value of start point

EndPoint Double

The value of end point

StepDivision Flag

The division of steps

Nonlinear Table

The nonlinear vs frequency point array

Division Table

The frequency vs division point array

TimeVsFrequency Table The frequency vs time point array

Study Properties(ControlCircuit)

ControlCircuit properties

Property
(propName)
Type
(Type)
Flag
(scriptKeyName)

Description

FullModelConversion Flag
0 or Off
1 or On

Flag for Conversion to Value in Full Model
The result is not converted as a full model.
The result is converted as a full model.

ConversionFactor Double

Conversion factor excluding periodic boundary

ModelThickness Double

Thickness of the Model

ManualCoilLength Flag
0 or Off
1 or On

Flag of Independent Length of the Coil from Thickness of the Model
The length of FEM coil is independent from the thickness of the model.
The length of FEM coil is equal to the thickness of the model.

CoilLength Double

Length of the FEM Coil

Coupling Flag
0 or Off
1 or On

Flag for Coupled Analysis
Do not run the Coupled Analysis.
Run the coupled analysis.

CoupledRemesh Flag
0 or Off
1 or On

The flag for coupled remesh region
The region is not coupled remesh.
The air region is coupled remesh.

ConversionType Flag
0 or NotUse
2 or SeriesParallel

The flag of circuit conversion type
The circuit conversion is not used.
The circuit conversion type for series/parallel

CircuitConversionFactor Double

The conversion factor of circuit

CircuitConnect Flag
0 or Series
1 or Parallel
2 or AntiParallel

The circuit connect information
The series type
The parallel type
The anti parallel type

PowerCalcTolerance Double

The power calculation tolerance

PowerCalcInitialCurrent Double

The power calculation initial current

PowerCalcMaxIteration Flag

The calculation max iteration

Series Double

The number of series

Parallel Double

The number of parallel

ConnectionMode Flag
0 or ModifiedNodal
1 or ClosedLoop

Ths circuit analysis method
The modified nodal analysis type
The closed loop current analysis type

UseWindingFactor Flag
0 or Off
1 or On

The flag of use conversion factors from winding
Set conversion factors manually
Set conversion factors from winding

UseForceCorrection Flag
0 or Off
1 or On

The Force Correction
The force correction is not used.
The force correction is used.

SymmetryPlane1 Coordinate

The symmetry plane 1 for the force correction

CalculationMethod Flag
0 or Direct
2 or Iterative

Flag of Calculation Method Type
Use FEM+BEM calculation method.
Use FEM calculation method.

ApproximateTransientAnalysis Flag
0 or Off
1 or On

The flag for use steady-state approximate transient analysis
Do not use steady-state approximate transient analysis
Use steady-state approximate transient analysis

SpecifySlip Flag
0 or Off
1 or On

The flag for stationary device or induction motor
Set as stationary device.
User can specify slip as induction motor.

SteadyLinear Flag
0 or Nonlinear
1 or Linear

The flag to control non-linear type for pseudo steady state analysis.
Use conventional method of quasi steady state analysis.
Use fast acceleration of quasi-steady state analysis.

Slip Double

Slip value(s <= 1)

OutputSteadyResultAs1stStep Flag
0 or Off
1 or On

The flag for output steady result as 1st step
Do not output steady result as 1st step
Output steady result as 1st step

SetPseudoSteadyStateFreq Flag
0 or Off
1 or On

The flag for setting pseudo-steady state frequency
Do not use frequency for pseudo steady-state
Use frequency for pseudo steady-state

PseudoSteadyStateFrequency Double

pseudo steady-state frequency

SetUseCorrectBHCurve Flag
0 or Off
1 or On

The flag for using correct bh curve for pseudo-steady state
Do not use correct bh curve for pseudo steady-state
Use correct bh curve for pseudo steady-state

TimePeriodicEEC Flag
0 or Off
1 or On

The flag for time periodic explicit error correction
The time periodic explicit error correction is not executed.
The time periodic explicit error correction is executed.

TimePeriodicType Flag
1 or AntiPeriodic
2 or Periodic

The flag of time periodic type
Anti-Periodic
Periodic

ReversePeriodic Flag
0 or Off
1 or On

The flag reverse periodic rotor
The reverse periodic rotor is not used.
The reverse periodic rotor is used.

UseRelaxation Flag
0 or Off
1 or On

The flag use non-linear relaxation
Non-linear relaxation is not used
Use non-linear relaxation.

CorrectionType Flag
0 or frequency
1 or step

The flag for correction type
The correction type is frequency.
The correction type is step.

CorrectionFrequency Double

Frequency of correction

CorrectionInterval Flag

Interval of correction step

MaxCorrections Flag

Max number of correction process

FailureConvergenceError Flag
0 or Off
1 or On

The flag to handle the failure of convergence as an error
Warning.
Error(Solver will terminate).

ShortenCorrectionInterval Flag
0 or Off
1 or On

The flag for shortening interval check
Do usual interval check.
Shorten interval check.

AllStepsTransientCalculation Flag
0 or Off
1 or On

The flag for calculate and output all steps of transient calculation
Do not calculate and output all steps of transient calculation.
Calculate and output all steps of transient calculation.

UseGPU Flag
0 or Off
1 or On

The flag for use GPU
Not use GPU.
Use GPU.

RestartType Flag
0 or NotRestart
1 or FromTR

The restart type
Do not use restart.
Restart

RestartSavFile String

The sav file for restart

RestartMsvFile String

The msv file for restart

RestartSvcFile String

The svc file for restart

DirectSolverType Flag
0 or ICCG
1 or Direct
2 or Auto

The flag of linear solver type
ICCG
Direct solver
Auto

IccgAccel Double

Value of Acceleration Coefficient

AutoAccel Flag
0 or Off
1 or On

Flag to Set Acceleration Coefficient Automatically
The acceleration coefficient is set in manual.
The acceleration coefficient is automatically set.

ICCGToleranceType Flag
1 or Automatic
2 or Constant
4 or ScaleIndependent

Flag of ICCG Calculation Type
The ICCG tolerance is scaled using the original matrix right hand side vector. The tolerance is then adjusted automatically at each iteration.
The same ICCG tolerance is used for all NR iterations and is scaled using the original matrix right hand side vector.
The ICCG tolerance is scaled by the residual independently for each matrix solution.

InitialTolerance Double

Value of Initial Convergence Tolerance

MinimumTolerance Double

Value of Minimum Convergence Tolerance.

IccgTolerance Double

Value of Convergence Tolerance

IccgLimit Double

Value of Divergence Limit

IccgMaxIteration Flag

Value of Maximum Iteration

IccgToleranceScaleIndependent Double

The value of convergence tolerance.(Scale independent)

IccgOptimumValue Flag
0 or Off
1 or On

Flag of Convergence Refinement
No Refinement
Optimum Refinement

NonlinearMethod Flag
0 or Newton-Raphson
1 or SuccessiveIteration

Nonlinear Iterative Calculation Type
Newton-Raphson
Successive Iteration

ConvergenceType Flag
0 or Solution
1 or ResidualVector
2 or MagneticFluxDensityAndCircuit
3 or SolutionExcludingCircuit
4 or ResidualVectorExcludingCircuit
5 or MagneticFluxDensity

Convergence determination type
Using Variation of Solution
Using Magnitude of Residual Vector
Using Variation of Magnetic Flux Density and Circuit Variables
Using Variation of Solution (Excluding Circuit Variables)
Using Magnitude of Residual Vector (Excluding Circuit Variables)
Using Variation of Magnetic Flux Density

RelaxationFactor Flag
0 or Off
1 or Type1
2 or Type2
5 or FactorAuto

Flag of Relaxation Factor Type
No Relaxation
Relaxation Type 1
The relaxation type2
The relaxation auto

NonlinearMaxIteration Flag

Number of Nonlinear Iteration

NonlinearTolerance Double

Value of Nonlinear Iterative Convergence Tolerance

NonlinearConvergenceB Flag
0 or Off
1 or On

The maximum amount of change flag of the magnetic flux density
Not set the maximum amount of change in the magnetic flux density
To set the maximum amount of change in the magnetic flux density

NonlinearConvergenceV Flag
0 or Off
1 or On

The maximum amount of change flag of the voltage
Not set the maximum amount of change in the voltage
To set the maximum amount of change in the voltage

NonlinearConvergenceI Flag
0 or Off
1 or On

The maximum amount of change flag of the current
Not set the maximum amount of change in the current
To set the maximum amount of change in the current

NonlinearConvergenceToleranceB Double

The maximum amount of change in the magnetic flux density

NonlinearConvergenceToleranceV Double

The maximum amount of change in the voltage

NonlinearConvergenceToleranceI Double

The maximum amount of change in the current

NonlinearStrictConvergence Flag
0 or Off
0 or Off
1 or On
1 or On

Flag of Strict Judgment of Nonlinear Iterative Calculation
Normal judgment for convergence of nonlinear
Normal judgment for convergence of nonlinear
Strict judgment for convergence of nonlinear
Strict judgment for convergence of nonlinear

NonlinearSpeedup Flag
0 or Off
1 or On

Flag of Using Nonlinear Speeding-up Function
Do not use speeding up nonlinear calculation.
Use speeding up nonlinear calculation.

BHCorrection Flag
0 or Off
1 or On

Flag for applying a correction to the BH curve for frequency response analysis.
Do not apply BH curve correction.
Use BH curve correction.

MagneticFluxDensity Flag
0 or Off
1 or On

The flag for output magnetic flux density result
Not output the magnetic flux density.
Output the magnetic flux density.

Magnetization Flag
0 or Off
1 or On

The flag for output magnetization
Not output the magnetization.
Output the magnetization.

PermeanceFactor Flag
0 or Off
1 or On

The flag for output permeance factor
Not output the permeance factor.
Output the permeance factor.

Permeability Flag
0 or Off
1 or On

The flag for output permeability
Not output the permeability.
Output the permeability.

DifferentialPermeability Flag
0 or Off
1 or On

The flag for output differential permeability
Not output the differential permeability.
Output the differential permeability.

CurrentDensity Flag
0 or Off
1 or On

The flag for output current density result
Not output the current density.
Output the current density.

LossDensity Flag
0 or Off
1 or On

The flag for output loss density
Not output the loss density.
Output the loss density.

Displacement Flag
0 or Off
1 or On

The flag for output nodal displacement result
Not output the nodal displacement.
Output the nodal displacement.

NodalForce Flag
0 or Off
1 or On

The flag for output nodal force result
Not output the nodal force.
Output the nodal force.

SurfaceForceDensity Flag
0 or Off
1 or On

The flag for surface force density
Not output the surface force density.
Output the surface force density.

LorentzForceDensity Flag
0 or Off
1 or On

The flag for output Lorentz force density
Not output the Lorentz force density.
Output the lorentz force density.

VectorPotential Flag
0 or Off
1 or On

The flag for output vector potential
Not output the vector potential.
Output the vector potential.

Energy Flag
0 or Off
1 or On

The flag for output energy result
Not output the energy.
Output the energy.

Stress Flag
0 or Off
1 or On

The flag for output stress result
Not output the stress.
Output the stress.

DemagnetizationRatio Flag
0 or Off
1 or On

The flag for output demagnetization ratio (Compared to reference step)
Not output the Demagnetization ratio (Compared to reference step).
Output the Demagnetization ratio (Compared to reference step).

DemagnetizationRatioDiffUnDemag Flag
0 or Off
1 or On

The flag for output demagnetization ratio (Compared to undemagnetized state)
Not output the Demagnetization ratio (Compared to undemagnetized state).
Output the Demagnetization ratio (Compared to undemagnetized state).

HysteresisLossDensity Flag
0 or Off
1 or On

The flag for output hysteresis loss density
Not output the hysteresis loss density
Output the hysteresis loss density

RestartFile Flag
0 or Off
1 or On

The flag for output restart file
Not output the restart file.
Output the restart file.

RestartFileOutputInterval Flag

The minimum output interval(minute) for restart file

SolverReportFile Flag
0 or Off
1 or On

The flag for output solver report file
Not output the solver report file.
Output the solver report file.

InitialMagnetization Flag
0 or Off
1 or On

The flag for initial magnetization
Not output the initial magnetization.
Output the initial magnetization.

CoerciveForceNormal Flag
0 or Off
1 or On

The flag to control output of normalized Coercive Force
Do not output the normalized coercive force.
Output the normalized coercive force.

MagnetizationRatio Flag
0 or Off
1 or On

The flag to control output of magnetization ratio
Do not output the magnetization ratio.
Output the magnetization ratio.

Temperature Flag
0 or Off
1 or On

The flag for output temperature
Not output the temperature.
Output the temperature.

IronLossDensity Flag
0 or Off
1 or On

The flag for output iron loss density
Not output the ironloss density.
Output the ironloss density.

ElectricField Flag
0 or Off
1 or On

The flag for output electric field result
Not output the electric field.
Output the electric field.

MagneticFluxDensityLamination Flag
0 or Off
1 or On

The flag to output lamination magnetic flux density
Not output the lamination magnetic flux density
Output the lamination magnetic flux density

MagneticFieldStrengthLamination Flag
0 or Off
1 or On

The flag to output lamination magnetic field strength
Not output the lamination magnetic field strength
Output the lamination magnetic field strength

EddyCurrentDensityLamination Flag
0 or Off
1 or On

The flag to output lamination eddy current density
Not output the lamination eddy current density
Output the lamination eddy current density

CurrentLossDensityLamination Flag
0 or Off
1 or On

The flag to output lamination current loss density
Not output the lamination current loss density
Output the lamination current loss density

HysteresisLossDensityLamination Flag
0 or Off
1 or On

The flag to output lamination hysteresis loss density
Not output the lamination hysteresis loss density
Output the lamination hysteresis loss density

CriticalCurrentDensity Flag
0 or Off
1 or On

The flag to output critical current density
Not output the critical current density
Output the critical current density

IronRefMagneticFluxDensity Flag
0 or Off
1 or On

The flag for output reference magnetic flux density result (Iron)
Not output the reference magnetic flux density (Iron)
Output the reference magnetic flux density (Iron)

IronIronLossDensity Flag
0 or Off
1 or On

The flag for output iron loss density (Iron)
Not output the iron loss density (Iron)
Output the iron loss density (Iron)

IronHysteresisLossDensity Flag
0 or Off
1 or On

The flag for output hysteresis loss density (Iron)
Not output the hysteresis loss density (Iron)
Output the hysteresis loss density (Iron)

IronExcessEddyCurrentDensity Flag
0 or Off
1 or On

The flag for output excess eddy current loss density (Iron)
Not output the excess eddy current loss density (Iron)
Output the excess eddy current loss density (Iron)

IronClassicalEddyCurrentDensity Flag
0 or Off
1 or On

The flag for output classical eddy current loss density (Iron)
Not output the classical eddy current loss density (Iron)
Output the classical eddy current loss density (Iron)

IronJouleLossDensity Flag
0 or Off
1 or On

The flag for output Joule loss density (Iron)
Not output the Joule loss density (Iron)
Output the Joule loss density (Iron)

IronStress Flag
0 or Off
1 or On

The flag for output stress result (Iron)
Not output the stress (Iron)
Output the stress (Iron)

IronMagneticFluxDensityLamination Flag
0 or Off
1 or On

The flag to output lamination magnetic flux density (Iron)
Not output the lamination magnetic flux density (Iron)
Output the lamination magnetic flux density (Iron)

IronMagneticFieldStrengthLamination Flag
0 or Off
1 or On

The flag to output lamination magnetic field strength (Iron)
Not output the lamination magnetic field strength (Iron)
Output the lamination magnetic field strength (Iron)

IronEddyCurrentDensityLamination Flag
0 or Off
1 or On

The flag to output lamination eddy current density (Iron)
Not output the lamination eddy current density (Iron)
Output the lamination eddy current density (Iron)

IronCurrentLossDensityLamination Flag
0 or Off
1 or On

The flag to output lamination current loss density (Iron)
Not output the lamination current loss density (Iron)
Output the lamination current loss density (Iron)

IronHysteresisLossDensityLamination Flag
0 or Off
1 or On

The flag to output lamination hysteresis loss density (Iron)
Not output the lamination hysteresis loss density (Iron)
Output the lamination hysteresis loss density (Iron)

OutputTimingMode Flag
0 or Off
1 or FromStep
1 or On
2 or SpecifyInterval

A flag to control timing of output to plot file
Always output from 1st step.
Output from step specified in OutputStartStep.
Output from step specified in OutputStartStep.
Output from step specified Interval.

OutputStartStep Flag

The first step to use for the output

MinimizeResults Flag
0 or Off
1 or On

Flag to control minimization of output results
Do not minimize output of distributed results for output control
Minimize output of distributed results for output control

OutputIntervalTable Table

output control interval table

OutputTimingSameStep Flag
0 or Off
1 or On

Flag to use same step by table and field results
Output another step by table and field results
Output same step by table and field results

OutputResultsTimingMode Flag
0 or Off
1 or FromStep
1 or On
2 or SpecifyInterval
3 or NoOutput

Flag to control step output to result file
Output all steps
Output from step specified by OutputResultStartStep
Output from step specified by OutputResultStartStep
Output from step specified Interval
No Output

OutputResultsStartStep Flag

The first step to use for the output

OutputResultsIntervalTable Table

output control interval table

Hsusr1 Flag
0 or Off
1 or On

Flag of User Subroutine "hsusr1"
Do Not Use User Subroutine "hsusr1"
Use User Subroutine "hsusr1"

Hsusr3 Flag
0 or Off
1 or On

Flag of User Subroutine "hsusr3"
Do Not Use User Subroutine "hsusr3"
Use User Subroutine "hsusr3"

Hsusr4 Flag
0 or Off
1 or On

Flag of User Subroutine "hsusr4"
Do Not Use User Subroutine "hsusr4"
Use User Subroutine "hsusr4"

Usrfle Flag
0 or Off
1 or On

Flag of User Subroutine "usrfle"
Do Not Use User Subroutine "usrfle"
Use User Subroutine "usrfle"

Usrstp Flag
0 or Off
1 or On

Flag of User Subroutine "usrstp"
Do Not Use User Subroutine "usrstp"
Use User Subroutine "usrstp"

Usrlos Flag
0 or Off
1 or On

Flag of User Subroutine "usrlos"
Do Not Use User Subroutine "usrlos"
Use User Subroutine "usrlos"

Usrhys Flag
0 or Off
1 or On

Flag of User Subroutine "usrhys"
Do Not Use User Subroutine "usrhys"
Use User Subroutine "usrhys"

Usrfm2 Flag
0 or Off
1 or On

Flag of User Subroutine "usrfm2"
Do Not Use User Subroutine "usrfm2"
Use User Subroutine "usrfm2"

Usrfma Flag
0 or Off
1 or On
2 or usrfm3

The flag of user subroutine "usrfma"
Not use user subroutine "usrfma"
Use user subroutine "usrfma"
Use user subroutine "usrfm3"

Usrstr Flag
0 or Off
1 or On

The flag of user subroutine "usrstr"
Not use user subroutine "usrstr"
Use user subroutine "usrstr"

UsrArraySize Flag

The size of users subroutine point array

UsrsubName String

User Subroutine Name

Snapshot Flag
0 or Off
1 or On

The flag for Snapshot
Not use Snapshot
Use Snapshot

Retry Flag

Number of retries

Divisions Flag

Number of steps divided

Monitor Flag
0 or Off
1 or On

The flag to output monitoring file during analysis execution
Do not output the monitoring file during analysis execution
Output a monitoring file during analysis execution

CsvOutputPath String

The output path for the csv files

CsvResultTypes String

The list of result types to output the csv files

CsvOutputResponseData Flag

CSV file output response value

CsvOutputInductanceData Flag

CSV file output efficiency map inductance values

CsvOutputProbe Flag

CSV file output probe value

CsvOutputSection Flag

CSV file output section graph value

CsvOutputCalculation Flag

CSV file output calculation value

CsvOutputObjectiveData Flag

CSV file output objective value

CsvComponentType Flag
0 or RealImaginary
1 or AmplitudePhase
2 or RMS

Flag of component output type
Output real and imaginary
Output amplitude and phase
Output rms

CsvDivisionType Flag
0 or Off
1 or On

Flag of divide CSV file output by specified number of cases
Do not divide
Divide CSV output

CsvDivisionCase Flag

Specified number of cases

OutputControlType Flag
0 or SpecifyOutputResultItems
2 or DeleteResultFiles

The output control type
Specify Result Items to be Output.
Delete result files.

LogOutputLevel Flag
0 or Debug
1 or Information
2 or Warning
3 or Error
The log output level
Debug
Information
Warning
Error