JMAG Script Library

Sort condition
Newest first
Oldest first
Large number of views
  1. [D0009] Recommended settings for 3D FEM conductor conditions

    Apply recommended settings for 3D FEM conductor conditions.

    • [D0016] Extract anomalous eddy current loss coefficient

      Make anomalous eddy current loss coefficient table from a Custom material.

      • [D0032] Setup study for transfer function creation

        Set up a frequency analysis study for transfer function creation.

        • [D0037] Set Cooling (Forced Convection)

          Set Cooling by Forced Convection

          • [D0004] Set the coil material

            Sets the material for parts in the current study named "Coil" to copper.

            • [D0014] Calculate Efficiency from Drive Mode

              Uses results of the efficiency map analysis study to calculate efficiency of electric vehicles in a specified drive mode.

              • [D0028] Search Size Range in Optimization Table

                Search for the maximum value and the minimum value of the parametric variable range of optimization.

                • [D0007] Electrostatic Capacitance Coefficient Calculation

                  Outputs the capacitance coefficient of a system consisting of multiple conductors in CSV file format.

                  • [D0030] Allow Eddy Current for selected parts

                    This script sets the "Allow Eddy Current" flag for selected parts.

                    • [S8447] Script to add a case with modified design parameters including geometry dimensions.

                      I want to add a case and change design parameters including geometry dimensions with a script.

                      • [S8441] Script for performing FFT on torque waveforms and extracting the maximum amplitude from each frequency component

                        The following is an example of a script that performs FFT on torque waveforms and extracts the maximum amplitude from each frequency component. 

                        • [S8493] Script to calculate the induced voltage constant Ke from the analysis results and register it in the response value

                          The following is an example of a script that calculates the induced voltage constant Ke from the analysis results and registers it in the response value.

                          • [S8369] Script for performing Boolean operations by specifying part names in the Geometry Editor

                            The following is an example of a script that performs Boolean operations on specified parts using the Geometry Editor.

                            • [S9390] Script for setting the switching timing of the PAM inverter

                              The following is an example of a script for setting the switching timing of a PAM inverter.

                              • [S8401] Script for specifying parts by coordinates and setting conditions

                                The following is an example of a script that specifies parts by coordinates and sets conditions.

                                • [S8626] Script for setting skin depth based on material and frequency

                                  The following is an example of a script for setting the skin depth based on material and frequency.

                                  Search Filter

                                  • All Categories