Study
- Sort condition
- Newest first
- Oldest first
- Large number of views
-
[S0050] Create an arc section graph and obtain the result
Create a section graph retrieving the result values along an arc and display the result data table.
-
[S0049] Configure the response table creation for an efficiency map analysis study using a reduced order model method
Configure the settings of the response table creation for efficiency map analysis using a reduced order model method.
-
[S0048] Set the parametric variable ranges for optimization
In the optimization settings, configure the parametric variable ranges and select CAD parameters to modify the range using the range finder.
-
[S0045] Get the number of mesh elements and nodes
Get the number of elements and nodes of the mesh created in a study.
-
[S0043] Set parameter using a function to a condition of transient response analysis
Set parameters such as current and electric potential, which change depending on time, angle, etc., using functions.
-
[S0042] Create an efficiency map that has the drive cycle
Create an efficiency map with a drive cycle for the result evaluation of the efficiency map study.
-
[S0041] Create composite result display definition to display multiple distribution plots on a single screen
Create a composite result definition to plot different result types or different components for each part and display on a single screen.
-
[S0040] Create an equation in the case control
Create an equation of an expression type with specifying the display order on equation list.
-
[S0036] Set the Halbach array as the magnetization pattern for a permanent magnet
Set a parallel pattern (circular Halbach array) to permanent magnets arranged in the circumferential direction.
-
[S0035] Create a response table with corrections and skew applied in an efficiency map study
Apply correction parameters to the results of the efficiency map analysis study and create a new response table.
-
[S0034] Get the settings of measurement variables
Retrieved and display the settings of the measurement variables according to the measurement type.
-
[S0033] Define a 2D harmonic amplitude response value from a section graph data set
Create and register a 2D harmonic amplitude response value from a dataset of calculation results obtained on the time and spatial axes.
-
[S0031] Perform a 2D Fourier transform in time and space axes
Perform a 2D Fourier transform on a dataset of calculation results defined by the time axis and the spatial axis.
-
[S0029] Set a point array property to the analysis condition
Create and set a point array to the table type parameter in the analysis condition.
-
[S0028] Retrieve the values of winding parameters calculated based on the input parameters.
Get the values of coil parameters in the winding setting calculated from the input and the slot area on the model.
-
[S0027] Register a user-defined response value
Register the user-defined response values using a proprietary calculation method from the analysis results output by JMAG.


