Magnetic Field

Sort condition
Newest first
Oldest first
Large number of views
  1. [JAC286] IPM Motor Iron Loss Analysis Accounting for PWM -Evaluation with Different Modulation Methods-

    In this example, the effects on iron loss when the modulation method for PWM control is changed are evaluated.

  2. [JAC010] Thermal Analysis of a Radiant Heater

    This Application Note explains how to carry out a thermal analysis using the thermal radiation phenomenon between a heater and a heated body to obtain the differences in temperatu…

  3. Sinfonia Technology Co., Ltd.

    As an electrical machine manufacturer, Sinfonia Technology boasts a diverse product lineup that leverages its technological development capabilities centered on rotation machines …

  4. [RTML-060] IM Constant rating 100(kW)

    Type: IM | Max Power: 100(kW) | Stator(Outside Diameter): 200(mm) | Height: 65(mm) | Voltage/Current: DC500(V)/600(A) | Rotor/Mover: Cage

  5. [RTML-059] IM Constant rating 100(kW)

    Type: IM | Max Power: 100(kW) | Stator(Outside Diameter): 125(mm) | Height: 259(mm) | Voltage/Current: DC600(V)/400(A) | Rotor/Mover: Cage

  6. [RTML-058] IM Constant rating 10(kW)

    Type: IM | Max Power: 10(kW) | Stator(Outside Diameter): 92.5(mm) | Height: 37(mm) | Voltage/Current: DC440(V)/200(A) | Rotor/Mover: Cage

  7. [RTML-057] IM Constant rating 1(kW)

    Type: IM | Max Power: 1(kW) | Stator(Outside Diameter): 57.5(mm) | Height: 20(mm) | Voltage/Current: DC100(V)/28.3(A) | Rotor/Mover: Cage

  8. [JAC251] Alternator Vibration Analysis

    In this example, the electromagnetic force generated in the stator core of a claw pole alternator is obtained, and acceleration is evaluated with an electromagnetic force - struct…

  9. [RTML-056] WFSM_08

    Type: WFSM | Max Power: 75(kW) | Stator(Outside Diameter): 400(mm) | Height: 65(mm) | Voltage/Current: DC500(V)/283(A), DC600(V)/50(A) | Rotor/Mover: WF | Number of Phases: 3

  10. [RTML-055] WFSM_07

    Type: WFSM | Max Power: 75(kW) | Stator(Outside Diameter): 212(mm) | Height: 200(mm) | Voltage/Current: DC600(V)/250(A), DC600(V)/45(A) | Rotor/Mover: WF | Number of Phases: 3

  11. [RTML-054] WFSM_06

    Type: WFSM | Max Power: 75(kW) | Stator(Outside Diameter): 212(mm) | Height: 200(mm) | Voltage/Current: DC600(V)/250(A), DC200(V)/20(A) | Rotor/Mover: WF | Number of Phases: 3

  12. [RTML-053] WFSM_05

    Type: WFSM | Max Power: 10(kW) | Stator(Outside Diameter): 185(mm) | Height: 50(mm) | Voltage/Current: DC240(V)/84.8(A), DC300(V)/35(A) | Rotor/Mover: WF | Number of Phases: 3

  13. [RTML-052] WFSM_04

    Type: WFSM | Max Power: 10(kW) | Stator(Outside Diameter): 185(mm) | Height: 40(mm) | Voltage/Current: DC240(V)/84.8(A), DC300(V)/50(A) | Rotor/Mover: WF | Number of Phases: 3

  14. [JAC018] Thermal Analysis of a Motor

    In this example, how to evaluate a motor's temperature distribution by creating a thermal analysis model that can investigate the loss analysis and temperature distribution in ord…

  15. [JAC273] Creating IPM Motor Efficiency Maps Accounting for AC Loss

    In this example, an IPM motor efficiency map that accounts for AC loss from a PWM is created, and a comparison with an efficiency map that does not account for AC loss is performe…

  16. [RTML-051] WFSM_03

    Type: WFSM | Max Power: 10(kW) | Stator(Outside Diameter): 115(mm) | Height: 150(mm) | Voltage/Current: DC240(V)/84.8(A), DC300(V)/15(A) | Rotor/Mover: WF | Number of Phases: 3

Search Filter

  • All Categories