EFFICIENCYMAP

Creating Efficiency Map

Sort condition
Newest first
Oldest first
Views
  1. 217 – Creating Efficiency Maps for 3-Phase Induction Motors

    In this example, the use of JMAG-RT Viewer to create efficiency maps for three-phase induction motors when drive temperatures change.

  2. 165 – Creating an Efficiency Map for an IPM Motor

    This Application Note presents the use of the JMAG-RT Viewer to create an efficiency map for an IPM motor.

  3. [RTML-038] IM Constant rating 10(kW)

    Type: IM | Max Power: 10k | Stator(Outside Diameter): 500(mm) | Height: 300(mm) | Voltage/Current: DC500(V)/250(A) | Rotor/Mover: Cago

  4. [RTML-037] IM Constant rating 1(kW)

    Type: IM | Max Power: 1k | Stator(Outside Diameter): 134(mm) | Height: 42(mm) | Voltage/Current: DC100(V)/5(A) | Rotor/Mover: Cago

  5. [RTML-036] PMSM/SPM Constant rating 100(kW)

    Type: PMSM | Max Power: 100k | Stator(Outside Diameter): 400(mm) | Height: 63(mm) | Voltage/Current: DC500(V)/200(A) | Rotor/Mover: SPM | Average torque(N·m): 179

  6. [RTML-035] PMSM/IPM Constant rating 100(kW)

    Type: PMSM | Max Power: 100k | Stator(Outside Diameter): 400(mm) | Height: 81(mm) | Voltage/Current: DC500(V)/200(A) | Rotor/Mover: IPM(flat) | Average torque(N·m): 179

  7. [RTML-034] PMSM/IPM Constant rating 100(kW)

    Type: PMSM | Max Power: 100k | Stator(Outside Diameter): 400(mm) | Height: 89(mm) | Voltage/Current: DC500(V)/200(A) | Rotor/Mover: IPM(Vshaped) | Average torque(N·m): 178

  8. [RTML-033] PMSM/SPM Constant rating 100(kW)

    Type: PMSM | Max Power: 100k | Stator(Outside Diameter): 400(mm) | Height: 51(mm) | Voltage/Current: DC500(V)/200(A) | Rotor/Mover: SPM | Average torque(N·m): 176

  9. [RTML-032] PMSM/IPM Constant rating 100(kW)

    Type: PMSM | Max Power: 100k | Stator(Outside Diameter): 400(mm) | Height: 65(mm) | Voltage/Current: DC500(V)/200(A) | Rotor/Mover: IPM(flat) | Average torque(N·m): 177

  10. [RTML-031] PMSM/IPM Constant rating 100(kW)

    Type: PMSM | Max Power: 100k | Stator(Outside Diameter): 400(mm) | Height: 63(mm) | Voltage/Current: DC500(V)/200(A) | Rotor/Mover: IPM(Vshaped) | Average torque(N·m): 177

  11. [RTML-030] PMSM/SPM Constant rating 100(kW)

    Type: PMSM | Max Power: 100k | Stator(Outside Diameter): 250(mm) | Height: 179(mm) | Voltage/Current: DC500(V)/200(A) | Rotor/Mover: SPM | Average torque(N·m): 178

  12. [RTML-029] PMSM/IPM Constant rating 100(kW)

    Type: PMSM | Max Power: 100k | Stator(Outside Diameter): 250(mm) | Height: 287(mm) | Voltage/Current: DC500(V)/200(A) | Rotor/Mover: IPM(flat) | Average torque(N·m): 178

  13. [RTML-028] PMSM/IPM Constant rating 100(kW)

    Type: PMSM | Max Power: 100k | Stator(Outside Diameter): 250(mm) | Height: 340(mm) | Voltage/Current: DC500(V)/200(A) | Rotor/Mover: IPM(Vshaped) | Average torque(N·m): 178

  14. [RTML-027] PMSM/SPM Constant rating 100(kW)

    Type: PMSM | Max Power: 100k | Stator(Outside Diameter): 250(mm) | Height: 181(mm) | Voltage/Current: DC500(V)/200(A) | Rotor/Mover: SPM | Average torque(N·m): 178

  15. [RTML-026] PMSM/IPM Constant rating 100(kW)

    Type: PMSM | Max Power: 100k | Stator(Outside Diameter): 250(mm) | Height: 250(mm) | Voltage/Current: DC500(V)/200(A) | Rotor/Mover: IPM(flat) | Average torque(N·m): 177

  16. [RTML-025] PMSM/IPM Constant rating 100(kW)

    Type: PMSM | Max Power: 100k | Stator(Outside Diameter): 250(mm) | Height: 259(mm) | Voltage/Current: DC500(V)/200(A) | Rotor/Mover: IPM(Vshaped) | Average torque(N·m): 178

Search Filter

  • All Categories