DP

Transient Magnetic (2D/Axisymmetric)

Sort condition
Newest first
Oldest first
Large number of views
  1. [JFT188] Creation and Use of Surrogate Models Using Multiple Analysis Case Results

    This document describes the procedures to create a surrogate model using results from an analysis with multiple cases to review response value maps by calling that surrogate model…

  2. [JFT200] Function to Convert JMAG Thermal Circuits into MATLAB Thermal Circuits

    This tutorial describes the procedures to convert thermal circuits arranged in JMAG into MATLAB/Simulink thermal circuits to run system simulations.

    • [JAC306] Efficiency Map Creation for IPM Motor Considering Continuous Rating

      In this example, we will create an efficiency map for an IPM motor that considers continuous operation and imposes temperature constraints on the components.

    • [JAC307] Topology Optimization of SPM Motor Using the Magnet Orientation Direction as a Design Variable

      This case study runs an optimization to simultaneously explore the magnet topology and orientation directions through design variables to obtain at least the same torque as a Halb…

    • [JAC305] Loss Analysis of IPM Motor During Driving Cycle Considering Temperature Variation

      In this example, we evaluate the time variation of losses and temperature during WLTC driving cycles when using an efficiency map with temperature dependency in an IPM motor.

    • [RTML-062] WFSM_09 Open-End Winding

      Type: WFSM | Max Power: 75(kW) | Stator(Outside Diameter): 400(mm) | Height: 65(mm) | Voltage/Current: DC300(V)/283(A), DC600(V)/50(A) | Rotor/Mover: WF | Number of Phases: 3

    • [RTML-061] PMSM/IPM Constant rating 100(kW) 3-phase, Open-End Winding

      Type: PMSM | Max Power: 100(kW) | Stator(Outside Diameter): 250(mm) | Height: 259(mm) | Voltage/Current: DC350(V)/400(A) | Rotor: IPM

    • [RTML-060] IM Constant rating 100(kW)

      Type: IM | Max Power: 100(kW) | Stator(Outside Diameter): 200(mm) | Height: 65(mm) | Voltage/Current: DC500(V)/600(A) | Rotor/Mover: Cage

    • [RTML-059] IM Constant rating 100(kW)

      Type: IM | Max Power: 100(kW) | Stator(Outside Diameter): 125(mm) | Height: 259(mm) | Voltage/Current: DC600(V)/400(A) | Rotor/Mover: Cage

    • [RTML-058] IM Constant rating 10(kW)

      Type: IM | Max Power: 10(kW) | Stator(Outside Diameter): 92.5(mm) | Height: 37(mm) | Voltage/Current: DC440(V)/200(A) | Rotor/Mover: Cage

    • [RTML-057] IM Constant rating 1(kW)

      Type: IM | Max Power: 1(kW) | Stator(Outside Diameter): 57.5(mm) | Height: 20(mm) | Voltage/Current: DC100(V)/28.3(A) | Rotor/Mover: Cage

    • [RTML-056] WFSM_08

      Type: WFSM | Max Power: 75(kW) | Stator(Outside Diameter): 400(mm) | Height: 65(mm) | Voltage/Current: DC500(V)/283(A), DC600(V)/50(A) | Rotor/Mover: WF | Number of Phases: 3

    • [RTML-055] WFSM_07

      Type: WFSM | Max Power: 75(kW) | Stator(Outside Diameter): 212(mm) | Height: 200(mm) | Voltage/Current: DC600(V)/250(A), DC600(V)/45(A) | Rotor/Mover: WF | Number of Phases: 3

    • [RTML-054] WFSM_06

      Type: WFSM | Max Power: 75(kW) | Stator(Outside Diameter): 212(mm) | Height: 200(mm) | Voltage/Current: DC600(V)/250(A), DC200(V)/20(A) | Rotor/Mover: WF | Number of Phases: 3

    • [RTML-053] WFSM_05

      Type: WFSM | Max Power: 10(kW) | Stator(Outside Diameter): 185(mm) | Height: 50(mm) | Voltage/Current: DC240(V)/84.8(A), DC300(V)/35(A) | Rotor/Mover: WF | Number of Phases: 3

    • [RTML-052] WFSM_04

      Type: WFSM | Max Power: 10(kW) | Stator(Outside Diameter): 185(mm) | Height: 40(mm) | Voltage/Current: DC240(V)/84.8(A), DC300(V)/50(A) | Rotor/Mover: WF | Number of Phases: 3

    Search Filter

    • All Categories