DP

Transient Magnetic (2D/Axisymmetric)

Sort condition
Newest first
Oldest first
Large number of views
  1. [JFT115] Recalculating Electromagnetic Force and Torque Waveforms

    This document describes the method for calculating electromagnetic force as the post-processing of magnetic field analysis.

    • [JAC034] Demagnetization Analysis of an SPM Motor

      This note presents the use of a magnetic field analysis to evaluate the demagnetizing ratio distribution of an of an SPM motor by changing the current flow.

    • [JAC292] Evaluating Energy Consumption During Drive Cycle Using Loss Maps with Temperature Dependency for IPM Motors

      In this example, loss maps with temperature dependency for an IPM motor are used to compare and evaluate the energy consumption and efficiency during a WLTC drive cycle while usin…

    • [JAC286] IPM Motor Iron Loss Analysis Accounting for PWM -Evaluation with Different Modulation Methods-

      In this example, the effects on iron loss when the modulation method for PWM control is changed are evaluated.

    • [JFT180] Topology Optimization Including Magnet Orientation Directions as Design Variables

      This document describes the procedures for running topology optimization, including the magnet orientation directions as design variables.

      • [RTML-060] IM Constant rating 100(kW)

        Type: IM | Max Power: 100(kW) | Stator(Outside Diameter): 200(mm) | Height: 65(mm) | Voltage/Current: DC500(V)/600(A) | Rotor/Mover: Cage

      • [RTML-059] IM Constant rating 100(kW)

        Type: IM | Max Power: 100(kW) | Stator(Outside Diameter): 125(mm) | Height: 259(mm) | Voltage/Current: DC600(V)/400(A) | Rotor/Mover: Cage

      • [RTML-058] IM Constant rating 10(kW)

        Type: IM | Max Power: 10(kW) | Stator(Outside Diameter): 92.5(mm) | Height: 37(mm) | Voltage/Current: DC440(V)/200(A) | Rotor/Mover: Cage

      • [RTML-057] IM Constant rating 1(kW)

        Type: IM | Max Power: 1(kW) | Stator(Outside Diameter): 57.5(mm) | Height: 20(mm) | Voltage/Current: DC100(V)/28.3(A) | Rotor/Mover: Cage

      • [RTML-056] WFSM_08

        Type: WFSM | Max Power: 75(kW) | Stator(Outside Diameter): 400(mm) | Height: 65(mm) | Voltage/Current: DC500(V)/283(A), DC600(V)/50(A) | Rotor/Mover: WF | Number of Phases: 3

      • [RTML-055] WFSM_07

        Type: WFSM | Max Power: 75(kW) | Stator(Outside Diameter): 212(mm) | Height: 200(mm) | Voltage/Current: DC600(V)/250(A), DC600(V)/45(A) | Rotor/Mover: WF | Number of Phases: 3

      • [RTML-054] WFSM_06

        Type: WFSM | Max Power: 75(kW) | Stator(Outside Diameter): 212(mm) | Height: 200(mm) | Voltage/Current: DC600(V)/250(A), DC200(V)/20(A) | Rotor/Mover: WF | Number of Phases: 3

      • [RTML-053] WFSM_05

        Type: WFSM | Max Power: 10(kW) | Stator(Outside Diameter): 185(mm) | Height: 50(mm) | Voltage/Current: DC240(V)/84.8(A), DC300(V)/35(A) | Rotor/Mover: WF | Number of Phases: 3

      • [RTML-052] WFSM_04

        Type: WFSM | Max Power: 10(kW) | Stator(Outside Diameter): 185(mm) | Height: 40(mm) | Voltage/Current: DC240(V)/84.8(A), DC300(V)/50(A) | Rotor/Mover: WF | Number of Phases: 3

      • [JAC273] Creating IPM Motor Efficiency Maps Accounting for AC Loss

        In this example, an IPM motor efficiency map that accounts for AC loss from a PWM is created, and a comparison with an efficiency map that does not account for AC loss is performe…

      • [RTML-051] WFSM_03

        Type: WFSM | Max Power: 10(kW) | Stator(Outside Diameter): 115(mm) | Height: 150(mm) | Voltage/Current: DC240(V)/84.8(A), DC300(V)/15(A) | Rotor/Mover: WF | Number of Phases: 3

      Search Filter

      • All Categories

      Remember me
      Sign In
      Create an account (Free) About authentication ID for JMAG website