DP

Transient Magnetic (2D/Axisymmetric)

Sort condition
Newest first
Oldest first
Large number of views
  1. [RTML-052] WFSM_04

    Type: WFSM | Max Power: 10(kW) | Stator(Outside Diameter): 185(mm) | Height: 40(mm) | Voltage/Current: DC240(V)/84.8(A), DC300(V)/50(A) | Rotor/Mover: WF | Number of Phases: 3

  2. [RTML-053] WFSM_05

    Type: WFSM | Max Power: 10(kW) | Stator(Outside Diameter): 185(mm) | Height: 50(mm) | Voltage/Current: DC240(V)/84.8(A), DC300(V)/35(A) | Rotor/Mover: WF | Number of Phases: 3

  3. [RTML-054] WFSM_06

    Type: WFSM | Max Power: 75(kW) | Stator(Outside Diameter): 212(mm) | Height: 200(mm) | Voltage/Current: DC600(V)/250(A), DC200(V)/20(A) | Rotor/Mover: WF | Number of Phases: 3

  4. [RTML-055] WFSM_07

    Type: WFSM | Max Power: 75(kW) | Stator(Outside Diameter): 212(mm) | Height: 200(mm) | Voltage/Current: DC600(V)/250(A), DC600(V)/45(A) | Rotor/Mover: WF | Number of Phases: 3

  5. [RTML-056] WFSM_08

    Type: WFSM | Max Power: 75(kW) | Stator(Outside Diameter): 400(mm) | Height: 65(mm) | Voltage/Current: DC500(V)/283(A), DC600(V)/50(A) | Rotor/Mover: WF | Number of Phases: 3

  6. [RTML-057] IM Constant rating 1(kW)

    Type: IM | Max Power: 1(kW) | Stator(Outside Diameter): 57.5(mm) | Height: 20(mm) | Voltage/Current: DC100(V)/28.3(A) | Rotor/Mover: Cage

  7. [RTML-058] IM Constant rating 10(kW)

    Type: IM | Max Power: 10(kW) | Stator(Outside Diameter): 92.5(mm) | Height: 37(mm) | Voltage/Current: DC440(V)/200(A) | Rotor/Mover: Cage

  8. [RTML-059] IM Constant rating 100(kW)

    Type: IM | Max Power: 100(kW) | Stator(Outside Diameter): 125(mm) | Height: 259(mm) | Voltage/Current: DC600(V)/400(A) | Rotor/Mover: Cage

  9. [RTML-060] IM Constant rating 100(kW)

    Type: IM | Max Power: 100(kW) | Stator(Outside Diameter): 200(mm) | Height: 65(mm) | Voltage/Current: DC500(V)/600(A) | Rotor/Mover: Cage

  10. [RTML-061] PMSM/IPM Constant rating 100(kW) 3-phase, Open-End Winding

    Type: PMSM | Max Power: 100(kW) | Stator(Outside Diameter): 250(mm) | Height: 259(mm) | Voltage/Current: DC350(V)/400(A) | Rotor: IPM

  11. [RTML-062] WFSM_09 Open-End Winding

    Type: WFSM | Max Power: 75(kW) | Stator(Outside Diameter): 400(mm) | Height: 65(mm) | Voltage/Current: DC300(V)/283(A), DC600(V)/50(A) | Rotor/Mover: WF | Number of Phases: 3

  12. [JAC305] Loss Analysis of IPM Motor During Driving Cycle Considering Temperature Variation

    In this example, we evaluate the time variation of losses and temperature during WLTC driving cycles when using an efficiency map with temperature dependency in an IPM motor.

  13. [JAC307] Topology Optimization of SPM Motor Using the Magnet Orientation Direction as a Design Variable

    This case study runs an optimization to simultaneously explore the magnet topology and orientation directions through design variables to obtain at least the same torque as a Halb…

  14. [JAC306] Efficiency Map Creation for IPM Motor Considering Continuous Rating

    In this example, we will create an efficiency map for an IPM motor that considers continuous operation and imposes temperature constraints on the components.

  15. [JFT200] Function to Convert JMAG Thermal Circuits into MATLAB Thermal Circuits

    This tutorial describes the procedures to convert thermal circuits arranged in JMAG into MATLAB/Simulink thermal circuits to run system simulations.

    • [JFT188] Creation and Use of Surrogate Models Using Multiple Analysis Case Results

      This document describes the procedures to create a surrogate model using results from an analysis with multiple cases to review response value maps by calling that surrogate model…

    Search Filter