[RTML-037] IM Constant rating 1(kW)
Type: IM | Max Power: 1(kW) | Stator(Outside Diameter): 134(mm) | Height: 42(mm) | Voltage/Current: DC100(V)/5(A) | Rotor/Mover: Cage
-
[RTML-038] IM Constant rating 10(kW)
Type: IM | Max Power: 10(kW) | Stator(Outside Diameter): 500(mm) | Height: 300(mm) | Voltage/Current: DC500(V)/250(A) | Rotor/Mover: Cage
-
[JFT015] Procedure for Direct Coupled Analysis with JMAG and STAR-CCM+ Taking Thermal Fluid into Account (Ver.22.0 and After)
This document presents the procedure for two way coupled analysis considering thermal fluid by using JMAG and STAR-CCM+.
-
[RTML-051] WFSM_03
Type: WFSM | Max Power: 10(kW) | Stator(Outside Diameter): 115(mm) | Height: 150(mm) | Voltage/Current: DC240(V)/84.8(A), DC300(V)/15(A) | Rotor/Mover: WF | Number of Phases: 3
-
[RTML-052] WFSM_04
Type: WFSM | Max Power: 10(kW) | Stator(Outside Diameter): 185(mm) | Height: 40(mm) | Voltage/Current: DC240(V)/84.8(A), DC300(V)/50(A) | Rotor/Mover: WF | Number of Phases: 3
-
[RTML-053] WFSM_05
Type: WFSM | Max Power: 10(kW) | Stator(Outside Diameter): 185(mm) | Height: 50(mm) | Voltage/Current: DC240(V)/84.8(A), DC300(V)/35(A) | Rotor/Mover: WF | Number of Phases: 3
-
[RTML-054] WFSM_06
Type: WFSM | Max Power: 75(kW) | Stator(Outside Diameter): 212(mm) | Height: 200(mm) | Voltage/Current: DC600(V)/250(A), DC200(V)/20(A) | Rotor/Mover: WF | Number of Phases: 3
-
[RTML-055] WFSM_07
Type: WFSM | Max Power: 75(kW) | Stator(Outside Diameter): 212(mm) | Height: 200(mm) | Voltage/Current: DC600(V)/250(A), DC600(V)/45(A) | Rotor/Mover: WF | Number of Phases: 3
-
[RTML-056] WFSM_08
Type: WFSM | Max Power: 75(kW) | Stator(Outside Diameter): 400(mm) | Height: 65(mm) | Voltage/Current: DC500(V)/283(A), DC600(V)/50(A) | Rotor/Mover: WF | Number of Phases: 3
-
[RTML-057] IM Constant rating 1(kW)
Type: IM | Max Power: 1(kW) | Stator(Outside Diameter): 57.5(mm) | Height: 20(mm) | Voltage/Current: DC100(V)/28.3(A) | Rotor/Mover: Cage
-
[RTML-058] IM Constant rating 10(kW)
Type: IM | Max Power: 10(kW) | Stator(Outside Diameter): 92.5(mm) | Height: 37(mm) | Voltage/Current: DC440(V)/200(A) | Rotor/Mover: Cage
-
[RTML-059] IM Constant rating 100(kW)
Type: IM | Max Power: 100(kW) | Stator(Outside Diameter): 125(mm) | Height: 259(mm) | Voltage/Current: DC600(V)/400(A) | Rotor/Mover: Cage
-
[RTML-060] IM Constant rating 100(kW)
Type: IM | Max Power: 100(kW) | Stator(Outside Diameter): 200(mm) | Height: 65(mm) | Voltage/Current: DC500(V)/600(A) | Rotor/Mover: Cage
-
[JAC292] Evaluating Energy Consumption During Drive Cycle Using Loss Maps with Temperature Dependency for IPM Motors
In this example, loss maps with temperature dependency for an IPM motor are used to compare and evaluate the energy consumption and efficiency during a WLTC drive cycle while usin…
-
SIMBA, Reinventing Motor Drive Simulation
Ryoko Imamura, Powersys
-
Model-Based Calibration Enables Optimal Torque Control of Synchronous Motors in a Short Time
Atsushi Katagiri, MathWorks Japan