MBD

Sort condition
Newest first
Oldest first
Large number of views
  1. [RTML-037] IM Constant rating 1(kW)

    Type: IM | Max Power: 1(kW) | Stator(Outside Diameter): 134(mm) | Height: 42(mm) | Voltage/Current: DC100(V)/5(A) | Rotor/Mover: Cage

  2. [RTML-038] IM Constant rating 10(kW)

    Type: IM | Max Power: 10(kW) | Stator(Outside Diameter): 500(mm) | Height: 300(mm) | Voltage/Current: DC500(V)/250(A) | Rotor/Mover: Cage

  3. [JFT015] Procedure for Direct Coupled Analysis with JMAG and STAR-CCM+ Taking Thermal Fluid into Account (Ver.22.0 and After)

    This document presents the procedure for two way coupled analysis considering thermal fluid by using JMAG and STAR-CCM+.

  4. [RTML-051] WFSM_03

    Type: WFSM | Max Power: 10(kW) | Stator(Outside Diameter): 115(mm) | Height: 150(mm) | Voltage/Current: DC240(V)/84.8(A), DC300(V)/15(A) | Rotor/Mover: WF | Number of Phases: 3

  5. [RTML-052] WFSM_04

    Type: WFSM | Max Power: 10(kW) | Stator(Outside Diameter): 185(mm) | Height: 40(mm) | Voltage/Current: DC240(V)/84.8(A), DC300(V)/50(A) | Rotor/Mover: WF | Number of Phases: 3

  6. [RTML-053] WFSM_05

    Type: WFSM | Max Power: 10(kW) | Stator(Outside Diameter): 185(mm) | Height: 50(mm) | Voltage/Current: DC240(V)/84.8(A), DC300(V)/35(A) | Rotor/Mover: WF | Number of Phases: 3

  7. [RTML-054] WFSM_06

    Type: WFSM | Max Power: 75(kW) | Stator(Outside Diameter): 212(mm) | Height: 200(mm) | Voltage/Current: DC600(V)/250(A), DC200(V)/20(A) | Rotor/Mover: WF | Number of Phases: 3

  8. [RTML-055] WFSM_07

    Type: WFSM | Max Power: 75(kW) | Stator(Outside Diameter): 212(mm) | Height: 200(mm) | Voltage/Current: DC600(V)/250(A), DC600(V)/45(A) | Rotor/Mover: WF | Number of Phases: 3

  9. [RTML-056] WFSM_08

    Type: WFSM | Max Power: 75(kW) | Stator(Outside Diameter): 400(mm) | Height: 65(mm) | Voltage/Current: DC500(V)/283(A), DC600(V)/50(A) | Rotor/Mover: WF | Number of Phases: 3

  10. [RTML-057] IM Constant rating 1(kW)

    Type: IM | Max Power: 1(kW) | Stator(Outside Diameter): 57.5(mm) | Height: 20(mm) | Voltage/Current: DC100(V)/28.3(A) | Rotor/Mover: Cage

  11. [RTML-058] IM Constant rating 10(kW)

    Type: IM | Max Power: 10(kW) | Stator(Outside Diameter): 92.5(mm) | Height: 37(mm) | Voltage/Current: DC440(V)/200(A) | Rotor/Mover: Cage

  12. [RTML-059] IM Constant rating 100(kW)

    Type: IM | Max Power: 100(kW) | Stator(Outside Diameter): 125(mm) | Height: 259(mm) | Voltage/Current: DC600(V)/400(A) | Rotor/Mover: Cage

  13. [RTML-060] IM Constant rating 100(kW)

    Type: IM | Max Power: 100(kW) | Stator(Outside Diameter): 200(mm) | Height: 65(mm) | Voltage/Current: DC500(V)/600(A) | Rotor/Mover: Cage

  14. [JAC292] Evaluating Energy Consumption During Drive Cycle Using Loss Maps with Temperature Dependency for IPM Motors

    In this example, loss maps with temperature dependency for an IPM motor are used to compare and evaluate the energy consumption and efficiency during a WLTC drive cycle while usin…

  15. SIMBA, Reinventing Motor Drive Simulation

    Ryoko Imamura, Powersys

  16. Model-Based Calibration Enables Optimal Torque Control of Synchronous Motors in a Short Time

    Atsushi Katagiri, MathWorks Japan