[RTML-058] IM Constant rating 10(kW)
Type: IM | Max Power: 10(kW) | Stator(Outside Diameter): 92.5(mm) | Height: 37(mm) | Voltage/Current: DC440(V)/200(A) | Rotor/Mover: Cage
-
[RTML-057] IM Constant rating 1(kW)
Type: IM | Max Power: 1(kW) | Stator(Outside Diameter): 57.5(mm) | Height: 20(mm) | Voltage/Current: DC100(V)/28.3(A) | Rotor/Mover: Cage
-
[JAC251] Alternator Vibration Analysis
In this example, the electromagnetic force generated in the stator core of a claw pole alternator is obtained, and acceleration is evaluated with an electromagnetic force - struct…
-
[RTML-056] WFSM_08
Type: WFSM | Max Power: 75(kW) | Stator(Outside Diameter): 400(mm) | Height: 65(mm) | Voltage/Current: DC500(V)/283(A), DC600(V)/50(A) | Rotor/Mover: WF | Number of Phases: 3
-
[RTML-055] WFSM_07
Type: WFSM | Max Power: 75(kW) | Stator(Outside Diameter): 212(mm) | Height: 200(mm) | Voltage/Current: DC600(V)/250(A), DC600(V)/45(A) | Rotor/Mover: WF | Number of Phases: 3
-
[RTML-054] WFSM_06
Type: WFSM | Max Power: 75(kW) | Stator(Outside Diameter): 212(mm) | Height: 200(mm) | Voltage/Current: DC600(V)/250(A), DC200(V)/20(A) | Rotor/Mover: WF | Number of Phases: 3
-
[RTML-053] WFSM_05
Type: WFSM | Max Power: 10(kW) | Stator(Outside Diameter): 185(mm) | Height: 50(mm) | Voltage/Current: DC240(V)/84.8(A), DC300(V)/35(A) | Rotor/Mover: WF | Number of Phases: 3
-
[RTML-052] WFSM_04
Type: WFSM | Max Power: 10(kW) | Stator(Outside Diameter): 185(mm) | Height: 40(mm) | Voltage/Current: DC240(V)/84.8(A), DC300(V)/50(A) | Rotor/Mover: WF | Number of Phases: 3
-
[JAC018] Thermal Analysis of a Motor
In this example, how to evaluate a motor's temperature distribution by creating a thermal analysis model that can investigate the loss analysis and temperature distribution in ord…
-
[JAC273] Creating IPM Motor Efficiency Maps Accounting for AC Loss
In this example, an IPM motor efficiency map that accounts for AC loss from a PWM is created, and a comparison with an efficiency map that does not account for AC loss is performe…
-
[RTML-051] WFSM_03
Type: WFSM | Max Power: 10(kW) | Stator(Outside Diameter): 115(mm) | Height: 150(mm) | Voltage/Current: DC240(V)/84.8(A), DC300(V)/15(A) | Rotor/Mover: WF | Number of Phases: 3
-
[JAC253] Analysis of an Induction Generator
In this example, the relationship between the output power and efficiency of the induction generator is shown here.
-
[RTML-038] IM Constant rating 10(kW)
Type: IM | Max Power: 10(kW) | Stator(Outside Diameter): 500(mm) | Height: 300(mm) | Voltage/Current: DC500(V)/250(A) | Rotor/Mover: Cage
-
[RTML-037] IM Constant rating 1(kW)
Type: IM | Max Power: 1(kW) | Stator(Outside Diameter): 134(mm) | Height: 42(mm) | Voltage/Current: DC100(V)/5(A) | Rotor/Mover: Cage
-
[L-MB-30] Accurately Identifying Motor Characteristics During Control with JMAG-RT
In general, the characteristics of motor models used in control circuit simulation of a motor drive system are often assumed to be constant when the motor is in drive mode.
-
[L-SE-163] High Performance Massive Case Calculations
Taking the traction motor, auxiliary motor, and reactor as models to be analyzed, presented in this report is the performance for simultaneously running 100 cases by using Power S…