Transformer / Reactor
- Sort condition
- Newest first
- Oldest first
- Large number of views
-
[JAC184] Reactor Sound Pressure Analysis taking Magnetostriction into Account
These notes will conduct an analysis of changed vibratory force and show a case study of confirming the impact magnetostriction has on vibration noise.
-
[JAC075] Iron Loss Analysis of a Reactor
This Application Note analyzes the iron loss of a reactor.
-
[JAC143] Inductance Analysis of an Air Core Coil
This analysis shows how to obtain an air core coil’s inductance through analysis and compare it with theoretical values.
-
[JAC133] Thermal Analysis of a Three-phase Transformer
This Application Note presents an example of how to confirm a temperature distribution using the iron and copper losses of a three-phase transformer as heat sources.
-
[JAC146] Analysis of Stray Loss in a Transformer
This Application Note explains how to obtain losses in a transformer tank and use them to evaluate the temperature distribution in each part.
-
[JAC081] AL-value Analysis of a Choke Coil
This Application Note explains a case example that obtains the air gap versus AL characteristics of a choke coil.
-
[JAC152] Electromagnetic Force Analysis of Short-circuited Power Transformer Coils
This analysis uses different coil positions to evaluate the Lorentz force density and electromagnetic force produced in the coils during a short circuit in order to confirm the ef…
-
[JAC158] Superimposed Direct Current Characteristic Analysis of a Reactor That Accounts for Minor Hysteresis Loops
This Application Note presents the use of the frozen permeability condition to obtain the superimposed direct current characteristic that includes minor hysteresis loops of a high…
-
[JAC078] Loss Analysis of a Sheet Coil Transformer
This Application Note shows how to obtain the iron loss of a sheet coil transformer.
-
[JAC123] Thermal Analysis of a Choke Coil
This Application Note shows the use of a thermal analysis to obtain the temperature distribution using the iron losses and copper losses in the choke coil as the heat source.
-
[JAC132] Loss Analysis of a Three-phase Transformer
This note presents how to obtain the iron and copper losses of a three-phase transformer.
-
[JAC117] Iron Loss Analysis of a Transformer
This Application Note presents how to obtain the iron loss and the ratio of hysteresis loss and joule loss within that iron loss for a three-phase transformer.
-
[JAC061] Current Distribution Analysis of a Choke Coil
This Application Note explains a case example that obtains the current distribution in a choke coil.
-
[JAC110] Loss Analysis of a Choke Coil
This Application Note shows how to obtain the iron loss and copper loss in a choke coil.
-
[JAC107] Current voltage characteristics analysis of flyback converters
In this example, this case study obtains the current waveform of the primary / secondary winding and the core magnetic flux density distribution, current density distribution insi…
-
[JAC148] Loss Analysis of a Power Transformer (Flyback Converter)
A magnetic field analysis simulation based on the finite element method (FEM) can precisely evaluate the complex loss distributions of the coil and core, so it is optimal for an a…


